BR-80 3+1 Type 2 80kA Surge Protective Device For TT And TNS

Ottieni un preventivo
Descrizione

Caratteristiche del prodotto:

Specifica BR-80 150 3+1 BR-80 275 3+1 BR-80 320 3+1 BR-80 385 3+1
SPD classification according to EN61643-11 Tipo 2 Tipo 2 Tipo 2 Tipo 2
SPD classification according to IEC61643-11 Class II Class II Class II Class II
Max. continuous operating a.c. voltage(L-N) Uc 150V 275V 320V 385V
Max. continuous operating a.c. voltage(N-PE) Uc 255V 255V 255V 255V
Corrente di scarica nominale (8/20μs) In 40kA 40kA 40kA 40kA
Massimo. corrente di scarica (8/20μs) Imax 80kA 80kA 80kA 80kA
Voltage protection level (L-N) Su ≤1.0kV ≤1.7kV ≤2.0kV ≤2.3kV
Voltage protection level 5kA (L-N) Su ≤0.6kV ≤1.0kV ≤1.1kV ≤1.2kV
Voltage protection level (N-PE) Su ≤1.5kV ≤1.5kV ≤1.5kV ≤1.5kV
Max. backup fuse 160A gG 160A gG 160A gG 160A gG
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA
Temporary overvoltage TOV-withstand (L-N) UT 180V/5sec. 335V/5sec. 400V/5sec. 500V/5sec.
Temporary overvoltage TOV-safe failure (L-N) UT 230V/120min. 440V/120min. 520V/120min. 650V/120min.
Temporary overvoltage TOV-withstand (N-PE) UT 1200V/200ms 1200V/200ms 1200V/200ms 1200V/200ms
Response time (L-N) tA ≤25ns ≤25ns ≤25ns ≤25ns
Response time (N-PE) tA ≤100ns ≤100ns ≤100ns ≤100ns
Intervallo di temperatura operativa Tu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red green/red
Area della sezione trasversale (Min.) 4mm² 4mm² 4mm² 4mm²
Area della sezione trasversale (max.) 35 mm² 35 mm² 35 mm² 35 mm²
Per il montaggio Guida DIN da 35 mm
Materiale della custodia Thermoplastic   UL94-V0
Grado di protezione IP20 IP20 IP20 IP20
Order Code B18292 B18294 B18296 B18298
Order Code (With remote signaling) B18293 B18295 B18297 B18888

Caratteristiche:

Max. discharge current (8/20 µs), Imax – 80kA.

Mounted: DIN rail.

Low voltage protection level.

Visual indication, green to red, when replacement of the cartridge is required.

Employs metal oxide varistor (MOV) technology.

Thermal isolating arrester disconnector offers a high level of protection against overload.

Compact size, good performance.

Applicazione:

For the protection of low voltage distribution systems against direct lightning strike into the overhead power supply line or external lightning protection system (IEC 62305).

Used in all standard power supply systems, such as distribution box for important electrical equipment of buildings, such as equipment room distribution box.

Generally installed in sub-distribution stations or machine control cabinets.

Used to protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage.

 

SIAMO QUI PER SUPPORTARTI!

Ulteriori informazioni o una consulenza personale? I nostri prodotti e il nostro know-how sono lì per fornire soluzioni.

PRODOTTI CORRELATI
NOTIZIE CORRELATE
POTRESTI ANCHE VEDERE
OTTIENI LA ​​PROTEZIONE DA SOVRATENSIONE
LA SOLUZIONE OGGI!
icona
icona
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.