BR-7M 1+1 7kA Dispositivo di protezione contro le sovratensioni Tipo 1+2 / B+C per TT e TNS

Ottieni un preventivo
Descrizione

Caratteristiche del prodotto:

Specifica BR-7M 150 1+1 BR-7M 275 1+1 BR-7M 320 1+1
SPD classification according to EN61643-11 Type 1 + Type 2 Type 1 + Type 2 Type 1 + Type 2
SPD classification according to IEC61643-11 Class I + Class II Class I + Class II Class I + Class II
Max. continuous operating a.c. voltage Uc(L-N/N-PE) 150V/255V(50/60Hz) 275V/255V(50/60Hz) 320V/255V(50/60Hz)
Corrente impulsiva di fulmine (10/350μs) Iimp(L-N/N-PE) 7kA/12.5kA 7kA/12.5kA 7kA/12.5kA
Corrente di scarica nominale (8/20μs) In(L-N/N-PE) 20kA/50kA 20kA/50kA 20kA/50kA
Massimo. corrente di scarica (8/20μs) Imax(L-N/N-PE) 50kA/100kA 50kA/100kA 50kA/100kA
Specific energy W/R(L-N/N-PE) 12.25kJ/Ω, 39kJ/Ω 12.25kJ/Ω, 39kJ/Ω 12.25kJ/Ω, 39kJ/Ω
Livello di protezione della tensione Up(L-N/N-PE) ≤0.8kV/≤1.5kV ≤1.3kV/≤1.5kV ≤1.5kV/≤1.5kV
Short-circuit current rating a.c. Isccr 25kA rms 25kA rms 25kA rms
Max. backup fuse 125A gG 125A gG 125A gG
Temporary overvoltage TOV-withstand UT(L-N) 180V/5sec. 335V/5sec. 400V/5sec.
Temporary overvoltage TOV-safe failure UT(L-N) 230V/120min. 440V/120min. 520V/120min.
Temporary overvoltage TOV-withstand UT(N-PE) 1200V/200ms 1200V/200ms 1200V/200ms
Tempo di risposta tA(L-N/N-PE) ≤25ns/≤100ns ≤25ns/≤100ns ≤25ns/≤100ns
Intervallo di temperatura operativa Tu -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red
Area della sezione trasversale (Min.) 4mm² 4mm² 4mm²
Area della sezione trasversale (max.) 35 mm² 35 mm² 35 mm²
Per il montaggio Guida DIN da 35 mm
Materiale della custodia Termoplastico UL94-V0
Grado di protezione IP20 IP20 IP20
Order Code B17330 B17332 B17334
Order Code (With remote signaling) B17331 B17333 B17335

Caratteristiche:

Surge arrester for low-voltage power supply system protection against surges.

SPD is suitable for AC 50/60HZ, TT power supply systems.

Protective device adopts 35mm Din rail type mounting.

Designed according to IEC61643-11 and GB18802.1 standards.

As the protector normal works that the pilot lamp is green.

Applicazione:

Widely suitable for TT system, for protecting the buildings.

Installazione:

Wiring according to the mark of surge protector according to the wiring diagram.

When installed according to the installation diagram shows the connection, where l (L1, L2, L3) for the line, n is neutral, PE ground wire, do not mistake. After the installation is complete, check that the protection unit is plugging in place, close the automatic circuit breaker (fuse) switch, check the working status is normal.

Protector in use during the fault display window should periodically verify and view state when red fault display window or remote Terminal outputs alarm signals, the protector fails, should be repaired or replaced in a timely manner.

 

SIAMO QUI PER SUPPORTARTI!

Ulteriori informazioni o una consulenza personale? I nostri prodotti e il nostro know-how sono lì per fornire soluzioni.

PRODOTTI CORRELATI
NOTIZIE CORRELATE
POTRESTI ANCHE VEDERE
OTTIENI LA ​​PROTEZIONE DA SOVRATENSIONE
LA SOLUZIONE OGGI!
icona
icona
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.