Caratteristiche del prodotto:
| Specifica | BR-50GR 150 2P | BR-50GR 275 2P | BR-50GR 350 2P | |
| SPD classification according to EN61643-11 | Type 1 + Type 2 | Type 1 + Type 2 | Type 1 + Type 2 | |
| SPD classification according to IEC61643-11 | Class I + Class II | Class I + Class II | Class I + Class II | |
| Nominal operating voltage | Un | 120V(50/60Hz) | 230V(50/60Hz) | 250V(50/60Hz) |
| Max. continuous operating a.c. voltage | Uc | 150V(50/60Hz) | 275V(50/60Hz) | 350V(50/60Hz) |
| Corrente impulsiva di fulmine (10/350μs) | Iimp | 50kA | 50kA | 50kA |
| Corrente di scarica nominale (8/20μs) | In | 50kA | 50kA | 50kA |
| Massimo. corrente di scarica (8/20μs) | Imax | 160kA | 160kA | 160kA |
| Quantity of electric charge | Q | 25As | 25As | 25As |
| Specific energy | W/R | 625kJ/Ω | 625kJ/Ω | 625kJ/Ω |
| Livello di protezione della tensione | Su | ≤1.5kV | ≤1.5kV | ≤1.5kV |
| Short-circuit current rating a.c. | Isccr | 25kA rms | 25kA rms | 25kA rms |
| Max. backup fuse | 350A gG | 350A gG | 350A gG | |
| Temporary overvoltage TOV-withstand | UT | 230V/120min. | 440V/120min. | 580V/120min. |
| Tempo di risposta | tA | ≤100ns | ≤100ns | ≤100ns |
| Intervallo di temperatura operativa | Tu | -40℃-80℃ | -40℃-80℃ | -40℃-80℃ |
| Operating state/fault indication | green/red | green/red | green/red | |
| Area della sezione trasversale (Min.) | 4mm² | 4mm² | 4mm² | |
| Area della sezione trasversale (max.) | 35 mm² | 35 mm² | 35 mm² | |
| Per il montaggio | Guida DIN da 35 mm | |||
| Materiale della custodia | Termoplastico UL94-V0 | |||
| Grado di protezione | IP20 | IP20 | IP20 | |
| Order Code | B17162 | B18127 | B17188 | |
| Order Code (With remote signaling) | B17163 | B18128 | B17189 | |
Caratteristiche:
BR-50GR 2P is suitable for TN system.
Poles number: 2P.
Width of one pole: 36mm.
Uc 150V / 275V /350V can be achieved.
Fault indication via red mark in the inspection window.
35mm DIN rail mountable.
With remote signaling contact for control device for your option.
In accordance with EN / IEC 61643.
High security performance.
Easy maintenance.
Red indicates broken, replacement notice, which is clear and easy distinguished.
Applicazione:
Used in the main distribution boards, for use primarily on mains power distribution systems to protect connected facility from transient overvoltage.
Suitable for the low voltage main power distribution cabinet/box of buildings, and the facility connected between single phase AC power supply and system in parallel.
Use of attention:
1. The grounding path should be as short as possible, and the length should not exceed 1.5 meters.
2. When installing, pay attention to cables coming in and out of surge protective devices, so as to avoid the two coupling of surge.
3. The protected equipment must have good grounding, and the grounding impedance is in accordance with the relevant national standards.
4. After correct installation, it can work steadily for a long time. If it is found that the transmission performance of the system is reduced or the signal is interrupted due to the cause of surge protection, it should be maintained or replaced in time.
Ulteriori informazioni o una consulenza personale? I nostri prodotti e il nostro know-how sono lì per fornire soluzioni.