BR-40VG 4P Type 2 40kA Surge Protection

Ottieni un preventivo
Descrizione

Caratteristiche del prodotto:

Specifica BR-40VG 150 4P BR-40VG 275 4P BR-40VG 320 4P BR-40VG 385 4P BR-40VG 440 4P
SPD classification according to EN61643-11 Tipo 2 Tipo 2 Tipo 2 Tipo 2 Tipo 2
SPD classification according to IEC61643-11 Class II Class II Class II Class II Class II
Max. continuous operating a.c. voltage Uc 150V 275V 320V 385V 440V
Corrente di scarica nominale (8/20μs) In 20kA 20kA 20kA 20kA 20kA
Massimo. corrente di scarica (8/20μs) Imax 40kA 40kA 40kA 40kA 40kA
Livello di protezione della tensione Su ≤1.3kV ≤1.3kV ≤1.5kV ≤1.8kV ≤2.0kV
Max. backup fuse 100A gG 100A gG 100A gG 100A gG 100A gG
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA 25kA
Temporary overvoltage TOV-withstand UT 180V/5sec. 335V/5sec. 400V/5sec. 500V/5sec. 580V/5sec.
Temporary overvoltage TOV-safe failure UT 230V/120min. 440V/120min. 520V/120min. 650V/120min. 765V/120min.
Tempo di risposta tA ≤100ns ≤100ns ≤100ns ≤100ns ≤100ns
Intervallo di temperatura operativa Tu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red green/red green/red
Area della sezione trasversale (Min.) 4mm² 4mm² 4mm² 4mm² 4mm²
Area della sezione trasversale (max.) 35 mm² 35 mm² 35 mm² 35 mm² 35 mm²
Per il montaggio Guida DIN da 35 mm
Materiale della custodia Thermoplastic   UL94-V0
Grado di protezione IP20 IP20 IP20 IP20 IP20
Order Code B17506 B17518 B17530 B17542 B17554
Order Code (With remote signaling) B17507 B17519 B17531 B17543 B17555

Caratteristiche:

Electric ratings: 230/400V, AC50/60Hz, 3-phase;

In: 20kA.

Surge protective device, plug.

Uc 150V / 275V / 320V / 385V / 440V can be achieved.

Standard: IEC/EN 61643-11

Hot melt flow double protection.

The visual window color said protector working state; green (normal), red (fault).

The reaction time of less than 100 ns.

Number of poles: 4;

Short circuit current: up to 40kA (8/20μs);

Remote signaling can select.

It is designed as module and 35mm din rail mounting.

Consisting of a base part and plug-in protection modules.

Applicazione:

Protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage.

In order to shunt and pressure to limit indirect lightning current or other instantaneous overvoltage.

 

SIAMO QUI PER SUPPORTARTI!

Ulteriori informazioni o una consulenza personale? I nostri prodotti e il nostro know-how sono lì per fornire soluzioni.

PRODOTTI CORRELATI
NOTIZIE CORRELATE
POTRESTI ANCHE VEDERE
OTTIENI LA ​​PROTEZIONE DA SOVRATENSIONE
LA SOLUZIONE OGGI!
icona
icona
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.