BR-40DP Dispositivo di protezione da sovratensione compatto 3+1 40 kA per TT e TNS

Ottieni un preventivo
Descrizione

Caratteristiche del prodotto:

Specifica BR275-40DP 3+1 BR320-40DP 3+1
SPD classification according to EN61643-11 Type 2 + Type 3 Type 2 + Type 3
SPD classification according to IEC61643-11 Class II + Class III Class II + Class III
Max. continuous operating a.c. voltage Uc(L-N/N-PE) 275V/255V 320V/255V
Corrente di scarica nominale (8/20μs) In 20kA 20kA
Massimo. corrente di scarica (8/20μs) Imax 40kA 40kA
Combined impulse Uoc 10kV 10kV
Livello di protezione della tensione Up(L-N/N-PE) ≤1.3kV/≤1.5kV ≤1.5kV/≤1.5kV
Tempo di risposta tA ≤25ns ≤25ns
Intervallo di temperatura operativa Tu -40℃-80℃ -40℃-80℃
Indicazione dello stato operativo/guasto verde/rosso verde/rosso
Area della sezione trasversale (Min.) 2.5mm² 2.5mm²
Area della sezione trasversale (max.) 16mm² 16mm²
Per il montaggio Guida DIN da 35 mm Guida DIN da 35 mm
Materiale della custodia Termoplastico UL94-V0
Grado di protezione IP20 IP20
Codice ordine B18243 B17254
Codice d'ordine (con segnale remoto) B18244 B17255

Caratteristiche:

Type 2 + Type 3 Surge Protector.

Uc 275V/320V.

This three phase SPD din-rail for lightning protection and other spikes in electrical power has a maximum amperage of 40 kA.

Response time: ≤25ns.

Pole number: 2P, 4P, 1P+N, 3P+N.

UL 94 V-0 Thermoplastic Housing.

DIN rail compatible.

Remote Signaling in option.

Degree of protection: IP20.

Conforming fully to international IEC 61643-11 and EN 61643-11 standards.

It can provide type 3 protection for equipment which installed within 5 meters from these devices.

Applicazione:

For protection of power supply systems.

For the protection of low voltage distribution systems against transient overvoltage caused by indirect lightning stroke and switching operations.

For using in the lightning protection zones concept at boundary 2-3.

Applied to power supply protection of equipment system in areas with high lightning risk.

Installazione:

Suitable as the final stage of protection in panels with Type 2 protection devices installed upstream.

These SPDs should be installed as close as possible to the equipment being protected.

Installed at a minimum conductor length of 10 meters (30 feet) from the electrical service panel to the point of utilization, for example cord connected, direct plug-in, receptacle type SPDs installed at the utilization equipment being protected. The distance (10 meters) is exclusive of the conductors provided with or used to attach SPDs.

 

SIAMO QUI PER SUPPORTARTI!

Ulteriori informazioni o una consulenza personale? I nostri prodotti e il nostro know-how sono lì per fornire soluzioni.

PRODOTTI CORRELATI
NOTIZIE CORRELATE
POTRESTI ANCHE VEDERE
OTTIENI LA ​​PROTEZIONE DA SOVRATENSIONE
LA SOLUZIONE OGGI!
icona
icona
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.