BR-40 Dispositivo di protezione da sovratensione 3+1 Tipo 2 40 kA per TT e TNS

Ottieni un preventivo
Descrizione

Caratteristiche del prodotto:

Specifica BR-40 150 3+1 BR-40 275 3+1 BR-40 320 3+1 BR-40 385 3+1 BR-40 440 3+1
SPD classification according to EN61643-11 Tipo 2 Tipo 2 Tipo 2 Tipo 2 Tipo 2
SPD classification according to IEC61643-11 Class II Class II Class II Class II Class II
Max. continuous operating a.c. voltage(L-N) Uc 150V 275V 320V 385V 440V
Max. continuous operating a.c. voltage(N-PE) Uc 255V 255V 255V 255V 255V
Corrente di scarica nominale (8/20μs) In 20kA 20kA 20kA 20kA 20kA
Massimo. corrente di scarica (8/20μs) Imax 40kA 40kA 40kA 40kA 40kA
Voltage protection level (L-N) Su ≤0.8kV ≤1.3kV ≤1.5kV ≤1.8kV ≤2.0kV
Voltage protection level 5kA (L-N) Su ≤0.6kV ≤1kV ≤1.2kV ≤1.3kV ≤1.5kV
Voltage protection level (N-PE) Su ≤1.5kV ≤1.5kV ≤1.5kV ≤1.5kV ≤1.5kV
Max. backup fuse 100A gG 100A gG 100A gG 100A gG 100A gG
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA 25kA
Temporary overvoltage TOV-withstand (L-N) UT 180V/5sec. 335V/5sec. 400V/5sec. 500V/5sec. 580V/5sec.
Temporary overvoltage TOV-safe failure(L-N) UT 230V/120min. 440V/120min. 520V/120min. 650V/120min. 765V/120min.
Temporary overvoltage TOV-withstand(N-PE) UT 1200V/200ms 1200V/200ms 1200V/200ms 1200V/200ms 1200V/200ms
Response time (L-N) tA ≤25ns ≤25ns ≤25ns ≤25ns ≤25ns
Response time (N-PE) tA ≤100ns ≤100ns ≤100ns ≤100ns ≤100ns
Intervallo di temperatura operativa Tu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red green/red green/red
Area della sezione trasversale (Min.) 4mm² 4mm² 4mm² 4mm² 4mm²
Area della sezione trasversale (max.) 35 mm² 35 mm² 35 mm² 35 mm² 35 mm²
Per il montaggio Guida DIN da 35 mm
Materiale della custodia Thermoplastic   UL94-V0
Grado di protezione IP20 IP20 IP20 IP20 IP20
Order Code B18451 B18453 B18455 B18457 B18249
Order Code (With remote signaling) B18452 B18454 B18456 B18458 B18250

Caratteristiche:

40kA Class C for 3 Phase Supply.

It is compact devices designed to protect 3-phase+neutral networks at the main switchboard.

The product is complying with the standards: EN 61643-11, CEI 61643-11, UL1449 ed. 4 compliance.

The protection circuitry is based on high energy varistor with thermal disconnection devices.

Easy to operate.

There is an indicator on the cartridges to signal failure mode.

Long service life.

The BR-40 is DIN rail mounted and features replaceable modules for the safest and easiest installation and maintenance.

Excellent functionality

Consistent plug ability(even for N/PE spark gap)

BR-40 series are designed to protect against lighting surge voltages. These units must be installed in parallel on the AC networks to be protected and provide common and differential modes protection.

Thermal disconnect device for each individual connector

Surge Protection Device / Arrester are for protection against switching surges.

With or without floating remote indication contact

Time of response<25ns.

The color of the visible window shows operating status, green means normal, red means abnormal.

Applicazione:

These devices protect low-voltage consumer systems from over voltages of all types.

Protection of terminal devices.

For using in the zones concept at boundary 1-2.

Used for protection against electrical transients.

 

SIAMO QUI PER SUPPORTARTI!

Ulteriori informazioni o una consulenza personale? I nostri prodotti e il nostro know-how sono lì per fornire soluzioni.

PRODOTTI CORRELATI
NOTIZIE CORRELATE
POTRESTI ANCHE VEDERE
OTTIENI LA ​​PROTEZIONE DA SOVRATENSIONE
LA SOLUZIONE OGGI!
icona
icona
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.