Caratteristiche del prodotto:

Specifica BR-30FU 150 4P BR-30FU 275 4P BR-30FU 320 4P BR-30FU 385 4P BR-30FU 440 4P
SPD classification according to EN61643-11 Tipo 2 Tipo 2 Tipo 2 Tipo 2 Tipo 2
SPD classification according to IEC61643-11 Class II Class II Class II Class II Class II
Max. continuous operating a.c. voltage Uc 150V 275V 320V 385V 440V
Corrente di scarica nominale (8/20μs) In 15kA 15kA 15kA 15kA 15kA
Massimo. corrente di scarica (8/20μs) Imax 30kA 30kA 30kA 30kA 30kA
Livello di protezione della tensione Su ≤0.8kV ≤1.3kV ≤1.5kV ≤1.8kV ≤2.0kV
Voltage protection level 5kA Su ≤0.6kV ≤1kV ≤1.2kV ≤1.3kV ≤1.5kV
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA 25kA
Temporary overvoltage TOV-withstand UT 180V/5sec. 335V/5sec. 400V/5sec. 500V/5sec. 580V/5sec.
Temporary overvoltage TOV-safe failure UT 230V/120min. 440V/120min. 520V/120min. 650V/120min. 765V/120min.
Tempo di risposta tA ≤25ns ≤25ns ≤25ns ≤25ns ≤25ns
Intervallo di temperatura operativa Tu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red green/red green/red
Area della sezione trasversale (Min.) 4mm² 4mm² 4mm² 4mm² 4mm²
Area della sezione trasversale (max.) 35 mm² 35 mm² 35 mm² 35 mm² 35 mm²
Per il montaggio Guida DIN da 35 mm
Materiale della custodia Thermoplastic   UL94-V0
Grado di protezione IP20 IP20 IP20 IP20 IP20
Order Code B16106 B16118 B16130 B16142 B16154
Order Code (With remote signaling) B16107 B16119 B16131 B16143 B16155

Caratteristiche:

The surge arrestors BR-30FU meet the type 2 requirement class according to IEC 61643-11.

35mm electrical lead rail installation

Surge protective device, plug.

8/20us wave form, low residual voltage

Remote signaling port, remote alert

Hot melt flow double protection.

Connectable surge arrestor

The reaction time of less than 25 ns.

High arresting capacity

Visual status display

The maximum discharging currents (IMAX 8/20) of each line could be 30kA.

Labelled connections

Applicazione:

Type 2 Surge Arresters provide protection against overvoltage originating from switching and the secondary effects of lightning strikes.

In order to shunt and pressure to limit indirect lightning current or other instantaneous overvoltage.

Floor distribution box of buildings

Installazione:

• The type 2 arresters must install into sub-distribution boards after main distribution boards containing type 1 arresters.

• For proper operation between type 1 and type 2 arresters at least 10- 15 m cable or wire must be otherwise a decoupling coil have to install between the two devices.

• In areas where storms are frequent, it is strongly recommended to install additional protection systems.
SIAMO QUI PER SUPPORTARTI!

Ulteriori informazioni o una consulenza personale? I nostri prodotti e il nostro know-how sono lì per fornire soluzioni.

PRODOTTI CORRELATI
NOTIZIE CORRELATE
POTRESTI ANCHE VEDERE
OTTIENI LA ​​PROTEZIONE DA SOVRATENSIONE
LA SOLUZIONE OGGI!
icona
icona
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.