Caratteristiche del prodotto:

Specifica BR-25GS 150 1P+N BR-25GS 275 1P+N BR-25GS 320 1P+N
SPD classification according to EN61643-11 Type 1 + Type 2 Type 1 + Type 2 Type 1 + Type 2
SPD classification according to IEC61643-11 Class I + Class II Class I + Class II Class I + Class II
Nominal operating a.c. voltage Un 120V/240V(50/60Hz) 230V/400V(50/60Hz) 240V/415V(50/60Hz)
Max. continuous operating a.c. voltage Uc (L-N/N-PE) 150V/255V(50/60Hz) 275V/255V(50/60Hz) 320V/255V(50/60Hz)
Corrente impulsiva di fulmine (10/350μs) Iimp (L-N/N-PE) 25kA/50kA 25kA/50kA 25kA/50kA
Corrente di scarica nominale (8/20μs) In (L-N/N-PE) 25kA/50kA 25kA/50kA 25kA/50kA
Massimo. corrente di scarica (8/20μs) Imax (L-N/N-PE) 100kA/120kA 100kA/120kA 100kA/120kA
Quantity of electric charge Q (L-N/N-PE) 12.5As/25As 12.5As/25As 12.5As/25As
Specific energy W/R (L-N/N-PE) 156kJ/Ω, 625kJ/Ω 156kJ/Ω, 625kJ/Ω 156kJ/Ω, 625kJ/Ω
Livello di protezione della tensione Up (L-N/N-PE) ≤1.5kV/≤1.5kV ≤1.5kV/≤1.5kV ≤1.5kV/≤1.5kV
Max. backup fuse 200A gG 200A gG 200A gG
Short-circuit current rating a.c. Isccr 25kA 25kA 25kA
Follow current extinguishing capability a.c. Ifi (L-N/N-PE) 25kA/100A 25kA/100A 25kA/100A
Temporary overvoltage TOV-withstand UT (L-N) 230V/120min. 440V/120min. 580V/120min.
Temporary overvoltage TOV-withstand UT (N-PE) 1200V/200ms 1200V/200ms 1200V/200ms
Tempo di risposta tA ≤100ns ≤100ns ≤100ns
Leakage current Ipe <0.1mA <0.1mA <0.1mA
Intervallo di temperatura operativa Tu -40℃-85℃ -40℃-85℃ -40℃-85℃
Operating state/fault indication green/red green/red green/red
Area della sezione trasversale (Min.) 4mm² 4mm² 4mm²
Area della sezione trasversale (max.) 35 mm² 35 mm² 35 mm²
Per il montaggio Guida DIN da 35 mm
Materiale della custodia Termoplastico UL94-V0
Grado di protezione IP20 IP20 IP20
Order Code B17060 B17073 B17098
Order Code (With remote signaling) B17061 B17074 B17099
Suffixes: Add Suffix “RS” for dry contact remote signaling version. Example: BR-25GS 275 1P+N RS

Caratteristiche:

Remote signalling available.

35mm wide electrical installation guide rail.

Simple and easy to use. More reliable and more safety.

Surge protect, prevents home electric network receive excessive impact while lightning.

Number of poles: 1P+N

Applicazione:

For protecting low voltage equipment from surge damages.

This products is especially suitable for application in the A grade lightning protection in high risk area of lightning strike.

Suitable for indoor operation, if installed in the outdoor, must be equipped with waterproof shell.

It is mainly used for the first stage of lightning surge overvoltage protection in AC distribution system.

Used to protect electrical and electronic equipment from lightning electromagnetic pulse induced voltages, operating transients and overvoltages.

Widely used in communication equipment, power, security, traffic, industrial control and other fields of power protection.

Distribution box with overhead input in building.

Installazione:

Installations more than 10 m high (apartment buildings, office buildings, hotels, etc.): type 2 SPD recommended for protecting private areas and floor distributors (communal areas) in addition to a type 1 or type 1+2 SPDs.

SCHEMAS

SIAMO QUI PER SUPPORTARTI!

Ulteriori informazioni o una consulenza personale? I nostri prodotti e il nostro know-how sono lì per fornire soluzioni.

PRODOTTI CORRELATI
NOTIZIE CORRELATE
POTRESTI ANCHE VEDERE
OTTIENI LA ​​PROTEZIONE DA SOVRATENSIONE
LA SOLUZIONE OGGI!
icona
icona
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.