BR-12.5M 1P 12.5kA Type 1+2 Surge Protective Device

Ottieni un preventivo
Descrizione

Caratteristiche del prodotto:

Specifica BR-12.5M 150 1P BR-12.5M 275 1P BR-12.5M 320 1P
SPD classification according to EN61643-11 Type 1 + Type 2 Type 1 + Type 2 Type 1 + Type 2
SPD classification according to IEC61643-11 Class I + Class II Class I + Class II Class I + Class II
Max. continuous operating a.c. voltage Uc 150V(50/60Hz) 275V(50/60Hz) 320V(50/60Hz)
Corrente impulsiva di fulmine (10/350μs) Iimp 12.5kA 12.5kA 12.5kA
Corrente di scarica nominale (8/20μs) In 25kA 25kA 25kA
Massimo. corrente di scarica (8/20μs) Imax 60kA 60kA 60kA
Specific energy W/R 39kJ/Ω 39kJ/Ω 39kJ/Ω
Livello di protezione della tensione Su ≤0.8kV ≤1.3kV ≤1.5kV
Short-circuit current rating a.c. Isccr 25kA rms 25kA rms 25kA rms
Max. backup fuse 125A gG 125A gG 125A gG
Temporary overvoltage TOV-withstand UT(L-N) 180V/5sec. 335V/5sec. 400V/5sec.
Temporary overvoltage TOV-safe failure UT(L-N) 230V/120min. 440V/120min. 520V/120min.
Tempo di risposta tA ≤25ns ≤25ns ≤25ns
Intervallo di temperatura operativa Tu -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red
Area della sezione trasversale (Min.) 4mm² 4mm² 4mm²
Area della sezione trasversale (max.) 35 mm² 35 mm² 35 mm²
Per il montaggio Guida DIN da 35 mm
Materiale della custodia Termoplastico UL94-V0
Grado di protezione IP20 IP20 IP20
Order Code B18171 B18173 B18175
Order Code (With remote signaling) B18172 B18174 B18176

Caratteristiche:

Surge arrestor.

Meet the type 1+2 requirement class according to IEC 61643-11.

High arresting capacity up to 12.5 kA (10/350μs).

Visual status display.

The use of high-performance varistors permits a rapid response time and a low protection level, without any line follow current.

Available with optional remote signaling.

Simple standard Din rail mounting.

Labeled connections.

Uc: 150v, 275v, 320v.

Based on high energy Metal Oxide Varistors.

Versions with 1P, 1+NPE, 2P, 3P, 3+NPE and 4P.

Exclusive devices for TN-S, TN-C and TT systems.

Reversible chassis to allow cable entry from above or below.

Indoor fixed installation, voltage limited type.

Module design.

Large lightning current discharge capacity.

Easy to maintain.

When the SPD works normally, the visible window displays green, and when it fails, it displays red.

Time of response<25ns.

Could supply different working voltage level and lightning discharge current, also could customized according to different requirement.

Applicazione:

Usable in systems with lightning protection class 1+2.

Installazione:

Please connect according to the installation diagram; the connecting wires must meet the requirements.

When the failure display window of the module indicates red, it means that the lightning protection device has failed, and new products should be replaced in time.

 

SIAMO QUI PER SUPPORTARTI!

Ulteriori informazioni o una consulenza personale? I nostri prodotti e il nostro know-how sono lì per fornire soluzioni.

PRODOTTI CORRELATI
NOTIZIE CORRELATE
POTRESTI ANCHE VEDERE
OTTIENI LA ​​PROTEZIONE DA SOVRATENSIONE
LA SOLUZIONE OGGI!
icona
icona
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.