Caratteristiche del prodotto:
| Specifica | BR-12.5M 150 1P | BR-12.5M 275 1P | BR-12.5M 320 1P | |
| SPD classification according to EN61643-11 | Type 1 + Type 2 | Type 1 + Type 2 | Type 1 + Type 2 | |
| SPD classification according to IEC61643-11 | Class I + Class II | Class I + Class II | Class I + Class II | |
| Max. continuous operating a.c. voltage | Uc | 150V(50/60Hz) | 275V(50/60Hz) | 320V(50/60Hz) |
| Corrente impulsiva di fulmine (10/350μs) | Iimp | 12.5kA | 12.5kA | 12.5kA |
| Corrente di scarica nominale (8/20μs) | In | 25kA | 25kA | 25kA |
| Massimo. corrente di scarica (8/20μs) | Imax | 60kA | 60kA | 60kA |
| Specific energy | W/R | 39kJ/Ω | 39kJ/Ω | 39kJ/Ω |
| Livello di protezione della tensione | Su | ≤0.8kV | ≤1.3kV | ≤1.5kV |
| Short-circuit current rating a.c. | Isccr | 25kA rms | 25kA rms | 25kA rms |
| Max. backup fuse | 125A gG | 125A gG | 125A gG | |
| Temporary overvoltage TOV-withstand | UT(L-N) | 180V/5sec. | 335V/5sec. | 400V/5sec. |
| Temporary overvoltage TOV-safe failure | UT(L-N) | 230V/120min. | 440V/120min. | 520V/120min. |
| Tempo di risposta | tA | ≤25ns | ≤25ns | ≤25ns |
| Intervallo di temperatura operativa | Tu | -40℃-80℃ | -40℃-80℃ | -40℃-80℃ |
| Operating state/fault indication | green/red | green/red | green/red | |
| Area della sezione trasversale (Min.) | 4mm² | 4mm² | 4mm² | |
| Area della sezione trasversale (max.) | 35 mm² | 35 mm² | 35 mm² | |
| Per il montaggio | Guida DIN da 35 mm | |||
| Materiale della custodia | Termoplastico UL94-V0 | |||
| Grado di protezione | IP20 | IP20 | IP20 | |
| Order Code | B18171 | B18173 | B18175 | |
| Order Code (With remote signaling) | B18172 | B18174 | B18176 | |
Caratteristiche:
Surge arrestor.
Meet the type 1+2 requirement class according to IEC 61643-11.
High arresting capacity up to 12.5 kA (10/350μs).
Visual status display.
The use of high-performance varistors permits a rapid response time and a low protection level, without any line follow current.
Available with optional remote signaling.
Simple standard Din rail mounting.
Labeled connections.
Uc: 150v, 275v, 320v.
Based on high energy Metal Oxide Varistors.
Versions with 1P, 1+NPE, 2P, 3P, 3+NPE and 4P.
Exclusive devices for TN-S, TN-C and TT systems.
Reversible chassis to allow cable entry from above or below.
Indoor fixed installation, voltage limited type.
Module design.
Large lightning current discharge capacity.
Easy to maintain.
When the SPD works normally, the visible window displays green, and when it fails, it displays red.
Time of response<25ns.
Could supply different working voltage level and lightning discharge current, also could customized according to different requirement.
Applicazione:
Usable in systems with lightning protection class 1+2.
Installazione:
Please connect according to the installation diagram; the connecting wires must meet the requirements.
When the failure display window of the module indicates red, it means that the lightning protection device has failed, and new products should be replaced in time.
Ulteriori informazioni o una consulenza personale? I nostri prodotti e il nostro know-how sono lì per fornire soluzioni.