BR-110 Dispositivo di protezione da sovratensione 1+1 Tipo 2 110 kA per TT e TNS

Ottieni un preventivo
Descrizione

Caratteristiche del prodotto:

Specifica BR-110 275 1+1 BR-110 320 1+1 BR-110 385 1+1
SPD classification according to EN61643-11 Tipo 2 Tipo 2 Tipo 2
SPD classification according to IEC61643-11 Class II Class II Class II
Max. continuous operating a.c. voltage(L-N) Uc 275V 320V 385V
Max. continuous operating a.c. voltage(N-PE) Uc 255V 255V 255V
Corrente di scarica nominale (8/20μs) In 50kA 50kA 50kA
Massimo. corrente di scarica (8/20μs) Imax 110kA 110kA 110kA
Voltage protection level (L-N) Su ≤1.8kV ≤2.0kV ≤2.5kV
Voltage protection level 5kA (L-N) Su ≤1.0kV ≤1.1kV ≤1.2kV
Voltage protection level (N-PE) Su ≤1.5kV ≤1.5kV ≤1.5kV
Max. backup fuse 160A gG 160A gG 160A gG
Short-circuit withstand capacity Isccr 25kA 25kA 25kA
Temporary overvoltage TOV-withstand (L-N) UT 335V/5sec. 400V/5sec. 500V/5sec.
Temporary overvoltage TOV-safe failure(L-N) UT 440V/120min. 520V/120min. 650V/120min.
Temporary overvoltage TOV-withstand(N-PE) UT 1200V/200ms 1200V/200ms 1200V/200ms
Response time (L-N) tA ≤25ns ≤25ns ≤25ns
Response time (N-PE) tA ≤100ns ≤100ns ≤100ns
Intervallo di temperatura operativa Tu -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red
Area della sezione trasversale (Min.) 4mm² 4mm² 4mm²
Area della sezione trasversale (max.) 35 mm² 35 mm² 35 mm²
Per il montaggio Guida DIN da 35 mm
Materiale della custodia Thermoplastic   UL94-V0
Grado di protezione IP20 IP20 IP20
Order Code B18873 B18875 B18877
Order Code (With remote signaling) B18874 B18876 B18878

Caratteristiche:

1) Big discharger current capacity, low residual voltage, quick response

2) IP20, UL94 V0

3) Lowe leakage current and rate of change

4) Class II / Type 2 surge protective devices.

5) Heat isolation technique, no fire disaster

6) The core parts are metal oxide varistor components with high discharge capacity.

7) Apply special shock fuse pieces, with high reliability

8) Standard compliance: IEC61643-11, EN61643-11

9) With power indicator to display working condition

10) Protecting low voltage devices from surge for TN-S (or TT 1+1 mode as custom-made) power supply systems.

11) Temperature control protective circuit, built-in heat protection, automatic release unit

12) Mount on the 35mm DIN rail.

13) 1+1 protection model(L-N, N-PE), suitable for the poor power grid area

14) Nominal Discharge Current: 50kA

15) Max. Discharge Current: 110kA

16) Exquisite process, can work under the hostile environment for a long time, like acid, alkali, dust, salt fog, wet, etc.

Applicazione:

1) Three phase power SPD is suitable for system power protection, such as switching room, power distribution cabinet, switch cabinet, AC distribution board, etc.

2) For using in the lightning protection zones concept at boundary 1-2.

3) Distribution box with outdoor input in the building and each floor

4) AC power line of house, bank, and telecom tower and so on.

5) AC power surge protective device is used in AC power supply system (50/60Hz) and low-voltage control system to protect from lightning striker and transient over-voltage.

6) Automation machine room, power supply panel of converting station main control room

 

SIAMO QUI PER SUPPORTARTI!

Ulteriori informazioni o una consulenza personale? I nostri prodotti e il nostro know-how sono lì per fornire soluzioni.

PRODOTTI CORRELATI
NOTIZIE CORRELATE
POTRESTI ANCHE VEDERE
OTTIENI LA ​​PROTEZIONE DA SOVRATENSIONE
LA SOLUZIONE OGGI!
icona
icona
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.