Karakteristik produk:
| Spesifikasi | BRLED-DIN-MD | BRLED-DIN-MD-NG | |
| Klasifikasi SPD menurut EN61643-11 | Type 2 + Type 3 | Type 2 + Type 3 | |
| Klasifikasi SPD menurut IEC61643-11 | Class II + Class III | Class II + Class III | |
| Nominal a.c. voltage | Tidak | 230V | 230V |
| Maks. operasi terus menerus a.c. voltase | Uc | 320V | 320V |
| Norminal discharge current (8/20μs) | Di dalam | 5kA | 5kA |
| Maximum discharge current (8/20μs) | maksimal | 10kA | 10kA |
| Nominal current | IL | 5A | 5A |
| Combined impluse | Uoc | 10kV | 10kV |
| Tingkat perlindungan tegangan | Ke atas | ≤1.5kV | ≤1.5kV |
| Waktu respons | ta | ≤25ns | ≤25ns |
| Kisaran suhu pengoperasian | kamu | -40℃-80℃ | -40℃-80℃ |
| Operating state / fault indication | Green/Red | ||
| Enclosure materail | Termoplastik UL94-V0 | ||
| Tingkat perlindungan | IP20 | IP20 | |
| Order code | B6019 | B6020 | |
Fitur:
Classification: LED Lightning Surge Protector.
Space saving footprint for mounting in confined locations
Nominal Voltage (Un) is 230V.
Maximum continuous operating voltage (Uc) is 320V.
Nominal discharge surge current (In) is 5kA (8/20µs).
High performance to size ratio
Fully automatic operation
Rated for harsh environments
Features a thermally protected transient over-voltage circuit.
Aplikasi:
Suit for the outdoor luminaires such as street lights, flood lights etc.
Suitable for harsh environments, and provides high performance circuit protection that saves valuable LED lighting assets, reduces maintenance, prevents unwanted failures and decreases degradation damage for longer lifetimes.
Informasi lebih lanjut atau konsultasi pribadi? Produk dan pengetahuan kami hadir untuk memberikan solusi.