Karakteristik produk:

Spesifikasi BR-60 150 2P BR-60 275 2P BR-60 320 2P BR-60 385 2P
Klasifikasi SPD menurut EN61643-11 Tipe 2 Tipe 2 Tipe 2 Tipe 2
Klasifikasi SPD menurut IEC61643-11 Class II Class II Class II Class II
Maks. operasi terus menerus a.c. voltase Uc 150V 275V 320V 385V
Arus pelepasan nominal (8/20μs) Di dalam 30kA 30kA 30kA 30kA
Maks. arus pelepasan (8/20μs) maksimal 60kA 60kA 60kA 60kA
Tingkat perlindungan tegangan Ke atas ≤1.0kV ≤1.6kV ≤1.8kV ≤2.2kV
Voltage protection level 5kA Ke atas ≤0.5kV ≤0.6kV ≤1.0kV ≤1.2kV
Maks. sekering cadangan 160A gG 160A gG 160A gG 160A gG
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA
Tahan TOV tegangan lebih sementara UT 180V/5sec. 335V/5sec. 400V/5sec. 500V/5sec.
Temporary overvoltage TOV-safe failure UT 230V/120 menit. 440V/120 menit. 520V/120min. 650V/120min.
Waktu respons ta ≤25ns ≤25ns ≤25ns ≤25ns
Kisaran suhu pengoperasian kamu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Status pengoperasian/indikasi kesalahan hijau/merah hijau/merah hijau/merah hijau/merah
Luas penampang (Min.) 4mm² 4mm² 4mm² 4mm²
Luas penampang (Maks.) 35mm² 35mm² 35mm² 35mm²
Untuk pemasangan Rel Din 35mm
Bahan penutup Thermoplastic   UL94-V0
Tingkat perlindungan IP20 IP20 IP20 IP20
Kode Pesanan B18781 B18783 B18785 B18787
Kode Pesanan (Dengan sinyal jarak jauh) B18782 B18784 B18786 B18788

Fitur:

High Surge Energy capacity protects downstream loads from voltage spikes and line transients.

Connected in parallel and use an MOV to clamp high-voltage surges.

Thermal protection circuit disconnects load under high energy absorption events.

This device is primarily used in the main electrical panel for the protection of 1-phase systems.

Fail safe/self-protection design.

Visual red-green indicator alerts when surge module needs replacement.

Certified: IEC61643-11:2013, Class II.

Remote alarm contact.

Touch Safe, IP20 Degree of Protection

Surge module plugs into DIN Rail mount base assembly for easy replacement in field.

Double thermal disconnection device, provide more reliable protection.

Two pole device provides full protection.

High discharge current — Imax 60kA per pole.

Narrow size, special design for saving installation space — width 18mm/pole, single phase.

Aplikasi:

Useful in case of high lightning density areas.

This surge arrestor is suitable for all installations where risk of surge and spike activity and, particularly due to nearby lightning activity, as in telecom installations, oil rigs, and open exposed areas with metal structures.

This unit should be installed in all building and sites at high risk (where a Lightning Protection System is in place and there is risk to human life such as schools, hospitals etc.).

 

KAMI DI SINI UNTUK MENDUKUNG ANDA!

Informasi lebih lanjut atau konsultasi pribadi? Produk dan pengetahuan kami hadir untuk memberikan solusi.

PRODUK TERKAIT
BERITA TERKAIT
ANDA MUNGKIN JUGA INGIN MELIHAT
DAPATKAN PERLINDUNGAN Lonjakan
SOLUSI HARI INI!
ikon
ikon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.