BR-50GR 3+1 Type 1 50kA Surge Arrester for TT and TNS

Dapatkan Penawaran
Keterangan

Karakteristik produk:

Spesifikasi BR-50GR 150 3+1 BR-50GR 275 3+1 BR-50GR 350 3+1
Klasifikasi SPD menurut EN61643-11 Tipe 1 + Tipe 2 Tipe 1 + Tipe 2 Tipe 1 + Tipe 2
Klasifikasi SPD menurut IEC61643-11 Kelas I + Kelas II Kelas I + Kelas II Kelas I + Kelas II
Tegangan operasi nominal Tidak 120V/240V(50/60Hz) 230V/400V(50/60Hz) 250V/440V(50/60Hz)
Maks. operasi terus menerus a.c. voltase Uc (L-N/N-PE) 150V/255V(50/60Hz) 275V/255V(50/60Hz) 350V/255V(50/60Hz)
Arus impuls petir (10/350μs) Iimp (L-N/N-PE) 50kA/100kA 50kA/100kA 50kA/100kA
Arus pelepasan nominal (8/20μs) In (L-N/N-PE) 50kA/100kA 50kA/100kA 50kA/100kA
Maks. arus pelepasan (8/20μs) Imax (L-N/N-PE) 160kA/200kA 160kA/200kA 160kA/200kA
Quantity of electric charge (L-N, N-PE) Q 25As, 50As 25As, 50As 25As, 50As
Specific energy (L-N, N-PE) W/R 625kJ/Ω, 2500kJ/Ω 625kJ/Ω, 2500kJ/Ω 625kJ/Ω, 2500kJ/Ω
Tingkat perlindungan tegangan Up (L-N/N-PE) ≤1.5kV/≤1.5kV ≤1.5kV/≤1.5kV ≤1.5kV/≤1.5kV
Peringkat arus hubung singkat a.c. Isccr (L-N/N-PE) 25kA rms/100A rms 25kA rms/100A rms 25kA rms/100A rms
Maks. sekering cadangan 350A gG 350A gG 350A gG
Tahan TOV tegangan lebih sementara UT (L-N) 230V/120 menit. 440V/120 menit. 580V/120 menit.
Tahan TOV tegangan lebih sementara UT (N-PE) 1200V/200ms 1200V/200ms 1200V/200ms
Waktu respons ta ≤100ns ≤100ns ≤100ns
Kisaran suhu pengoperasian kamu -40℃-80℃ -40℃-80℃ -40℃-80℃
Status pengoperasian/indikasi kesalahan hijau/merah hijau/merah hijau/merah
Luas penampang (Min.) 4mm² 4mm² 4mm²
Luas penampang (Maks.) 35mm² 35mm² 35mm²
Untuk pemasangan Rel Din 35mm
Bahan penutup Termoplastik UL94-V0
Tingkat perlindungan IP20 IP20 IP20
Kode Pesanan B17166 B18167 B17192
Kode Pesanan (Dengan sinyal jarak jauh) B17167 B18168 B17193

Fitur:

Endurable, sustains multiple strikes.

LED status indication.

Protection class: Type 1+2, Class I +Class II.

BR-50GR 3P+N is suitable for TT and TN-S system.

Aplikasi:

● Suitable for TT and TN-S system.

● Used in industrial systems and buildings with external lightning protection of Classes I to IV.

● For the protection of low voltage distribution systems against direct lightning strike into the overhead power supply line or external lightning protection system.

● Can be used in standard distributor housing.

● Used to protect all kinds of electrical equipment in the power system from lightning over-voltage, operation over-voltage, power frequency transient over-voltage impact damage to an electrical appliance.

 

KAMI DI SINI UNTUK MENDUKUNG ANDA!

Informasi lebih lanjut atau konsultasi pribadi? Produk dan pengetahuan kami hadir untuk memberikan solusi.

PRODUK TERKAIT
BERITA TERKAIT
ANDA MUNGKIN JUGA INGIN MELIHAT
DAPATKAN PERLINDUNGAN Lonjakan
SOLUSI HARI INI!
ikon
ikon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.