BR-50GR 2P Type 1 50kA Surge Arrester for TNS

Dapatkan Penawaran
Keterangan

Karakteristik produk:

Spesifikasi BR-50GR 150 2P BR-50GR 275 2P BR-50GR 350 2P
Klasifikasi SPD menurut EN61643-11 Tipe 1 + Tipe 2 Tipe 1 + Tipe 2 Tipe 1 + Tipe 2
Klasifikasi SPD menurut IEC61643-11 Kelas I + Kelas II Kelas I + Kelas II Kelas I + Kelas II
Tegangan operasi nominal Tidak 120V(50/60Hz) 230V(50/60Hz) 250V(50/60Hz)
Maks. operasi terus menerus a.c. voltase Uc 150V(50/60Hz) 275V(50/60Hz) 350V(50/60Hz)
Arus impuls petir (10/350μs) Imp 50kA 50kA 50kA
Arus pelepasan nominal (8/20μs) Di dalam 50kA 50kA 50kA
Maks. arus pelepasan (8/20μs) maksimal 160kA 160kA 160kA
Jumlah muatan listrik Q 25As 25As 25As
Energi spesifik W/R 625kJ/Ω 625kJ/Ω 625kJ/Ω
Tingkat perlindungan tegangan Ke atas ≤1.5kV ≤1.5kV ≤1.5kV
Peringkat arus hubung singkat a.c. Isccr 25kA rms 25kA rms 25kA rms
Maks. sekering cadangan 350A gG 350A gG 350A gG
Tahan TOV tegangan lebih sementara UT 230V/120 menit. 440V/120 menit. 580V/120 menit.
Waktu respons ta ≤100ns ≤100ns ≤100ns
Kisaran suhu pengoperasian kamu -40℃-80℃ -40℃-80℃ -40℃-80℃
Status pengoperasian/indikasi kesalahan hijau/merah hijau/merah hijau/merah
Luas penampang (Min.) 4mm² 4mm² 4mm²
Luas penampang (Maks.) 35mm² 35mm² 35mm²
Untuk pemasangan Rel Din 35mm
Bahan penutup Termoplastik UL94-V0
Tingkat perlindungan IP20 IP20 IP20
Kode Pesanan B17162 B18127 B17188
Kode Pesanan (Dengan sinyal jarak jauh) B17163 B18128 B17189

Fitur:

BR-50GR 2P is suitable for TN system.

Poles number: 2P.

Width of one pole: 36mm.

Uc 150V / 275V /350V can be achieved.

Fault indication via red mark in the inspection window.

35mm DIN rail mountable.

With remote signaling contact for control device for your option.

In accordance with EN / IEC 61643.

High security performance.

Easy maintenance.

Red indicates broken, replacement notice, which is clear and easy distinguished.

Aplikasi:

Used in the main distribution boards, for use primarily on mains power distribution systems to protect connected facility from transient overvoltage.

Suitable for the low voltage main power distribution cabinet/box of buildings, and the facility connected between single phase AC power supply and system in parallel.

Use of attention:

1. The grounding path should be as short as possible, and the length should not exceed 1.5 meters.

2. When installing, pay attention to cables coming in and out of surge protective devices, so as to avoid the two coupling of surge.

3. The protected equipment must have good grounding, and the grounding impedance is in accordance with the relevant national standards.

4. After correct installation, it can work steadily for a long time. If it is found that the transmission performance of the system is reduced or the signal is interrupted due to the cause of surge protection, it should be maintained or replaced in time.

 

KAMI DI SINI UNTUK MENDUKUNG ANDA!

Informasi lebih lanjut atau konsultasi pribadi? Produk dan pengetahuan kami hadir untuk memberikan solusi.

PRODUK TERKAIT
BERITA TERKAIT
ANDA MUNGKIN JUGA INGIN MELIHAT
DAPATKAN PERLINDUNGAN Lonjakan
SOLUSI HARI INI!
ikon
ikon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.