BR-40VG 3+1 Type 2 40kA Lightning Protector

Dapatkan Penawaran
Keterangan

Karakteristik produk:

Spesifikasi BR-40VG 150 3+1 BR-40VG 275 3+1 BR-40VG 320 3+1 BR-40VG 385 3+1 BR-40VG 440 3+1
Klasifikasi SPD menurut EN61643-11 Tipe 2 Tipe 2 Tipe 2 Tipe 2 Tipe 2
Klasifikasi SPD menurut IEC61643-11 Class II Class II Class II Class II Class II
Max. continuous operating a.c. voltage(L-N) Uc 150V 275V 320V 385V 440V
Max. continuous operating a.c. voltage(N-PE) Uc 255V 255V 255V 255V 255V
Arus pelepasan nominal (8/20μs) Di dalam 20kA 20kA 20kA 20kA 20kA
Maks. arus pelepasan (8/20μs) maksimal 40kA 40kA 40kA 40kA 40kA
Voltage protection level (L-N) Ke atas ≤1.3kV ≤1.3kV ≤1.5kV ≤1.8kV ≤2.0kV
Voltage protection level (N-PE) Ke atas ≤1.5kV ≤1.5kV ≤1.5kV ≤1.5kV ≤1.5kV
Maks. sekering cadangan 100A gG 100A gG 100A gG 100A gG 100A gG
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA 25kA
Temporary overvoltage TOV-withstand (L-N) UT 180V/5sec. 335V/5sec. 400V/5sec. 500V/5sec. 580V/5sec.
Temporary overvoltage TOV-safe failure(L-N) UT 230V/120 menit. 440V/120 menit. 520V/120min. 650V/120min. 765V/120min.
Temporary overvoltage TOV-withstand(N-PE) UT 1200V/200ms 1200V/200ms 1200V/200ms 1200V/200ms 1200V/200ms
Response time (L-N) ta ≤100ns ≤100ns ≤100ns ≤100ns ≤100ns
Response time (N-PE) ta ≤100ns ≤100ns ≤100ns ≤100ns ≤100ns
Kisaran suhu pengoperasian kamu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Status pengoperasian/indikasi kesalahan hijau/merah hijau/merah hijau/merah hijau/merah hijau/merah
Luas penampang (Min.) 4mm² 4mm² 4mm² 4mm² 4mm²
Luas penampang (Maks.) 35mm² 35mm² 35mm² 35mm² 35mm²
Untuk pemasangan Rel Din 35mm
Bahan penutup Thermoplastic   UL94-V0
Tingkat perlindungan IP20 IP20 IP20 IP20 IP20
Kode Pesanan B17510 B17522 B17534 B17546 B17558
Kode Pesanan (Dengan sinyal jarak jauh) B17511 B17523 B17535 B17547 B17559

Fitur:

Consistent plug ability(even for N/PE spark gap)

It is compact devices designed to protect 3-phase+neutral networks at the main switchboard.

BR-40VG series Surge Protection are designed to protect against lighting surge voltages.

The protection circuitry is based on high energy varistor with thermal disconnection devices.

Maximum current of endure the lightning stroke 40KA.

There is an indicator on the cartridges to signal failure mode.

Thermal disconnect device for each individual connector

With or without floating remote indication contact

Time of response<100ns.

Din rail mountable (35 mm)

The color of the visible window shows operating status, green means normal, red means abnormal.

Conform to IEC61643-11 standards

AC Type 2 SPD is the secondary protection system for all low voltage electric installations.

This is installed in to each electrical switch boards and prevents the spread of surges in the electric systems, protecting the loads.

Aplikasi:

Suitable for system power protection, such as power distribution cabinet, switch cabinet, switch cabinet, AC distribution board, etc.

Protection of terminal devices.

BR-40VG AC SPD to protect from direct and indirect lightning impulse and other transient over voltage.

Used for protection against electrical transients.

 

KAMI DI SINI UNTUK MENDUKUNG ANDA!

Informasi lebih lanjut atau konsultasi pribadi? Produk dan pengetahuan kami hadir untuk memberikan solusi.

PRODUK TERKAIT
BERITA TERKAIT
ANDA MUNGKIN JUGA INGIN MELIHAT
DAPATKAN PERLINDUNGAN Lonjakan
SOLUSI HARI INI!
ikon
ikon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.