BR-40 1+1 Type 2 40kA Surge Protective Device For TT And TNS

Dapatkan Penawaran
Keterangan

Karakteristik produk:

Spesifikasi BR-40 150 1+1 BR-40 275 1+1 BR-40 320 1+1 BR-40 385 1+1 BR-40 440 1+1
Klasifikasi SPD menurut EN61643-11 Tipe 2 Tipe 2 Tipe 2 Tipe 2 Tipe 2
Klasifikasi SPD menurut IEC61643-11 Class II Class II Class II Class II Class II
Max. continuous operating a.c. voltage(L-N) Uc 150V 275V 320V 385V 440V
Max. continuous operating a.c. voltage(N-PE) Uc 255V 255V 255V 255V 255V
Arus pelepasan nominal (8/20μs) Di dalam 20kA 20kA 20kA 20kA 20kA
Maks. arus pelepasan (8/20μs) maksimal 40kA 40kA 40kA 40kA 40kA
Voltage protection level (L-N) Ke atas ≤0.8kV ≤1.3kV ≤1.5kV ≤1.8kV ≤2.0kV
Voltage protection level 5kA (L-N) Ke atas ≤0.6kV ≤1kV ≤1.2kV ≤1.3kV ≤1.5kV
Voltage protection level (N-PE) Ke atas ≤1.5kV ≤1.5kV ≤1.5kV ≤1.5kV ≤1.5kV
Maks. sekering cadangan 100A gG 100A gG 100A gG 100A gG 100A gG
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA 25kA
Temporary overvoltage TOV-withstand (L-N) UT 180V/5sec. 335V/5sec. 400V/5sec. 500V/5sec. 580V/5sec.
Temporary overvoltage TOV-safe failure(L-N) UT 230V/120 menit. 440V/120 menit. 520V/120min. 650V/120min. 765V/120min.
Temporary overvoltage TOV-withstand(N-PE) UT 1200V/200ms 1200V/200ms 1200V/200ms 1200V/200ms 1200V/200ms
Response time (L-N) ta ≤25ns ≤25ns ≤25ns ≤25ns ≤25ns
Response time (N-PE) ta ≤100ns ≤100ns ≤100ns ≤100ns ≤100ns
Kisaran suhu pengoperasian kamu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Status pengoperasian/indikasi kesalahan hijau/merah hijau/merah hijau/merah hijau/merah hijau/merah
Luas penampang (Min.) 4mm² 4mm² 4mm² 4mm² 4mm²
Luas penampang (Maks.) 35mm² 35mm² 35mm² 35mm² 35mm²
Untuk pemasangan Rel Din 35mm
Bahan penutup Thermoplastic   UL94-V0
Tingkat perlindungan IP20 IP20 IP20 IP20 IP20
Kode Pesanan B18251 B18253 B18255 B18257 B18370
Kode Pesanan (Dengan sinyal jarak jauh) B18252 B18254 B18256 B18258 B18371

Fitur:

Lightning surge protector with compact construction design

35mm2 DIN-rail in accordance with EN 50022/DIN46277-3

Application systems: TT, IT, and TN power supply system.

Protection mode: L-N, N-PE.

40kA Type 2 Class C AC Surge Protection Device.

Our offered surge protector is designed by utilizing the top grade material and the most advanced techniques.

Reliable control thanks to Thermo Dynamic Control disconnector.

Aplikasi:

For protection of consumer equipment against transient voltage caused by indirect lightning strike and switching operations.

Use in domestic, commercial and light industrial installations.

Usually installed in household power distribution boards, telecom machinery center, computer equipment center, elevator control center, hospital’s surgery and ICU, information equipment, electronic equipment and in front of control equipment or nearest socket box of control equipment.

Instalasi:

Usually installed in the distribution box office, the power phase line (L), neutral (N), respectively, corresponding surge protectors access terminals to ensure secure and reliable, and the surge protector ground terminal and ground as well electrical connection.

It should regularly check the work, such as the window turns red indicating the deterioration of its front open space, when the fuse is tripped, timely maintenance or replacement module.

After the installation is complete, check that the protection unit is plug in place, close the automatic circuit breaker (fuse) switch, check the working status is normal.

 

KAMI DI SINI UNTUK MENDUKUNG ANDA!

Informasi lebih lanjut atau konsultasi pribadi? Produk dan pengetahuan kami hadir untuk memberikan solusi.