BR-30FU 4P Type 2 30kA SPD

Dapatkan Penawaran
Keterangan

Karakteristik produk:

Spesifikasi BR-30FU 150 4P BR-30FU 275 4P BR-30FU 320 4P BR-30FU 385 4P BR-30FU 440 4P
Klasifikasi SPD menurut EN61643-11 Tipe 2 Tipe 2 Tipe 2 Tipe 2 Tipe 2
Klasifikasi SPD menurut IEC61643-11 Class II Class II Class II Class II Class II
Maks. operasi terus menerus a.c. voltase Uc 150V 275V 320V 385V 440V
Arus pelepasan nominal (8/20μs) Di dalam 15kA 15kA 15kA 15kA 15kA
Maks. arus pelepasan (8/20μs) maksimal 30kA 30kA 30kA 30kA 30kA
Tingkat perlindungan tegangan Ke atas ≤0.8kV ≤1.3kV ≤1.5kV ≤1.8kV ≤2.0kV
Voltage protection level 5kA Ke atas ≤0.6kV ≤1kV ≤1.2kV ≤1.3kV ≤1.5kV
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA 25kA
Tahan TOV tegangan lebih sementara UT 180V/5sec. 335V/5sec. 400V/5sec. 500V/5sec. 580V/5sec.
Temporary overvoltage TOV-safe failure UT 230V/120 menit. 440V/120 menit. 520V/120min. 650V/120min. 765V/120min.
Waktu respons ta ≤25ns ≤25ns ≤25ns ≤25ns ≤25ns
Kisaran suhu pengoperasian kamu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Status pengoperasian/indikasi kesalahan hijau/merah hijau/merah hijau/merah hijau/merah hijau/merah
Luas penampang (Min.) 4mm² 4mm² 4mm² 4mm² 4mm²
Luas penampang (Maks.) 35mm² 35mm² 35mm² 35mm² 35mm²
Untuk pemasangan Rel Din 35mm
Bahan penutup Thermoplastic   UL94-V0
Tingkat perlindungan IP20 IP20 IP20 IP20 IP20
Kode Pesanan B16106 B16118 B16130 B16142 B16154
Kode Pesanan (Dengan sinyal jarak jauh) B16107 B16119 B16131 B16143 B16155

Fitur:

The surge arrestors BR-30FU meet the type 2 requirement class according to IEC 61643-11.

35mm electrical lead rail installation

Surge protective device, plug.

8/20us wave form, low residual voltage

Remote signaling port, remote alert

Hot melt flow double protection.

Connectable surge arrestor

The reaction time of less than 25 ns.

High arresting capacity

Visual status display

The maximum discharging currents (IMAX 8/20) of each line could be 30kA.

Labelled connections

Aplikasi:

Type 2 Surge Arresters provide protection against overvoltage originating from switching and the secondary effects of lightning strikes.

In order to shunt and pressure to limit indirect lightning current or other instantaneous overvoltage.

Floor distribution box of buildings

Instalasi:

• The type 2 arresters must install into sub-distribution boards after main distribution boards containing type 1 arresters.

• For proper operation between type 1 and type 2 arresters at least 10- 15 m cable or wire must be otherwise a decoupling coil have to install between the two devices.

• In areas where storms are frequent, it is strongly recommended to install additional protection systems.
KAMI DI SINI UNTUK MENDUKUNG ANDA!

Informasi lebih lanjut atau konsultasi pribadi? Produk dan pengetahuan kami hadir untuk memberikan solusi.

PRODUK TERKAIT
BERITA TERKAIT
ANDA MUNGKIN JUGA INGIN MELIHAT
DAPATKAN PERLINDUNGAN Lonjakan
SOLUSI HARI INI!
ikon
ikon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.