Karakteristik produk:
| Spesifikasi | BR-25VG 320 2P | BR-25VG 440 2P | BR-25VG 690 2P | |
| Klasifikasi SPD menurut EN61643-11 | Type 1 + Type 2 +Type 3 | Type 1 + Type 2 +Type 3 | Type 1 + Type 2 +Type 3 | |
| Klasifikasi SPD menurut IEC61643-11 | Class I + Class II + Class III | Class I + Class II + Class III | Class I + Class II + Class III | |
| Tegangan operasi nominal | Tidak | 250V/440V(50/60Hz) | 250V/440V(50/60Hz) | 400V/690V(50/60Hz) |
| Maks. operasi terus menerus a.c. voltase | Uc | 320V(50/60Hz) | 440V(50/60Hz) | 690V(50/60Hz) |
| Arus impuls petir (10/350μs) | Imp | 25kA | 25kA | 25kA |
| Total discharge current (10/350μs) | Itotal | 50kA | 50kA | 50kA |
| Arus pelepasan nominal (8/20μs) | Di dalam | 30kA | 30kA | 30kA |
| Maks. arus pelepasan (8/20μs) | maksimal | 100kA | 100kA | 100kA |
| Jumlah muatan listrik | Q | 12.5A | 12.5A | 12.5A |
| Energi spesifik | W/R | 156kJ/Ω | 156kJ/Ω | 156kJ/Ω |
| Tingkat perlindungan tegangan | Ke atas | ≤1.5kV | ≤1.8kV | ≤2.5kV |
| Peringkat arus hubung singkat a.c. | Isccr | 25kA rms | 25kA rms | 25kA rms |
| Maks. sekering cadangan | 200A gG | 200A gG | 200A gG | |
| Tahan TOV tegangan lebih sementara | UT | 400V/5sec. | 580V/5sec. | 800V/5sec. |
| Temporary overvoltage TOV-safe failure | UT | 520V/120min. | 765V/120min. | 1000V/120min. |
| Leakage current | Ipe | None | None | None |
| Waktu respons | ta | ≤100ns | ≤100ns | ≤100ns |
| Kisaran suhu pengoperasian | kamu | -40℃-80℃ | -40℃-80℃ | -40℃-80℃ |
| Status pengoperasian/indikasi kesalahan | hijau/merah | hijau/merah | hijau/merah | |
| Luas penampang (Min.) | 4mm² | 4mm² | 4mm² | |
| Luas penampang (Maks.) | 35mm² | 35mm² | 35mm² | |
| Untuk pemasangan | Rel Din 35mm | |||
| Bahan penutup | Termoplastik UL94-V0 | |||
| Tingkat perlindungan | IP20 | IP20 | IP20 | |
| Kode Pesanan | B17265 | B17277 | B17289 | |
| Kode Pesanan (Dengan sinyal jarak jauh) | B17266 | B17278 | B17290 | |
Fitur:
Status indicator.
Powerful components, suitable for all kinds of common power systems.
No follow current.
The unit is designed to be used between Zone O and Zone 1 (according to IEC62305-4 definition of Lightning Protection Area).
Low voltage protection level.
Protection class: Type 1 + Type 2 + Type 3, Class I + Class II + Class III.
Installed in the main power distribution
Aplikasi:
• Prevents lightning overvoltage and transient overcurrent from intruding into the power supply line from disrupting the normal operation of the power supply system and electrical equipment.
• Ini berlaku untuk proteksi petir untuk sistem tenaga listrik di area dengan risiko petir tinggi (LPZ0B atau antarmuka antara LPZ0B dan LPZ1).
• Installed in the main power distribution box.
Instalasi:
• Power must be cut off before installation. Live operation is prohibited.
• It is recommended that a fuse or circuit breaker be connected in series at the front end of the surge protection.
• SPD is installed in parallel at the power supply inlet end of the building distribution box or the equipment room. The product is installed in the guide rail type. If conditions permit, the Kevin connection mode can be adopted.
• During installation, connect the device according to the installation diagram, where L is the phase line,N is the neutral line, and PE is the ground line. Do not misconnect the device. After the installation is complete, turn on the automatic circuit breaker and check whether the working status is normal.
• When the SPD is in use, check the status of the fault display window regularly. If the fault display window is red or the remote terminal outputs an alarm signal, it indicates that the SPD is faulty and should be repaired or replaced in time.
• Suitable for indoor operation, such as installed in the outdoor, must be equipped with waterproof shell.
Informasi lebih lanjut atau konsultasi pribadi? Produk dan pengetahuan kami hadir untuk memberikan solusi.