BR-25GR 4P Tipe 1 25kA Surge Arrester untuk TNS

Dapatkan Penawaran
Keterangan

Karakteristik produk:

Spesifikasi BR-25GR 150 4P BR-25GR 275 4P BR-25GR 350 4P
Klasifikasi SPD menurut EN61643-11 Tipe 1 + Tipe 2 Tipe 1 + Tipe 2 Tipe 1 + Tipe 2
Klasifikasi SPD menurut IEC61643-11 Kelas I + Kelas II Kelas I + Kelas II Kelas I + Kelas II
Tegangan operasi nominal Tidak 120V/240V(50/60Hz) 230V/400V(50/60Hz) 250V/440V(50/60Hz)
Maks. operasi terus menerus a.c. voltase Uc 150V(50/60Hz) 275V(50/60Hz) 350V(50/60Hz)
Arus impuls petir (10/350μs) Imp 25kA 25kA 25kA
Arus pelepasan nominal (8/20μs) Di dalam 25kA 25kA 25kA
Maks. arus pelepasan (8/20μs) maksimal 100kA 100kA 100kA
Jumlah muatan listrik Q 12.5A 12.5A 12.5A
Energi spesifik W/R 156kJ/Ω 156kJ/Ω 156kJ/Ω
Tingkat perlindungan tegangan Ke atas ≤1.5kV ≤1.5kV ≤1.5kV
Peringkat arus hubung singkat a.c. Isccr 25kA rms 25kA rms 25kA rms
Maks. sekering cadangan 315A gG 315A gG 315A gG
Tahan TOV tegangan lebih sementara UT 230V/120 menit. 440V/120 menit. 580V/120 menit.
Waktu respons ta ≤100ns ≤100ns ≤100ns
Kisaran suhu pengoperasian kamu -40℃-80℃ -40℃-80℃ -40℃-80℃
Status pengoperasian/indikasi kesalahan hijau/merah hijau/merah hijau/merah
Luas penampang (Min.) 4mm² 4mm² 4mm²
Luas penampang (Maks.) 35mm² 35mm² 35mm²
Untuk pemasangan Rel Din 35mm
Bahan penutup Termoplastik UL94-V0
Tingkat perlindungan IP20 IP20 IP20
Kode Pesanan B17120 B17133 B17146
Kode Pesanan (Dengan sinyal jarak jauh) B17121 B17134 B17147

Fitur:

• Can be used in TN-S system

• Remote and visual indication of protection device life status.

• The surge arrester meets IEC61643-1 Requirements for Class I surge protectors

• The unit is designed to be used between Zone 0 and Zone 1 (according to IEC62305-4 definition of Lightning Protection Area).

• BR-25GR 4P is designed to discharge high current surges without any destruction of the installation.

Aplikasi:

• The product is mainly used for primary protection of power system.

• Application-optimised and prewired combined lightning current and surge arrester for TN-S systems.

• Installed in the main power distribution box.

• Used to Industry and automation, commercial and residential installations, telecom & IT & data centers, water treatment, smart grid & LV metering, photovoltaic and wind etc.

Instalasi:

• Power must be cut off before installation. Live operation is prohibited.

• Suitable as the first step of protection in incoming power supply panels and areas with greater exposure to the atmosphere, where installations are usually provided with an external lightning protection system.

• It is recommended that a fuse or circuit breaker be connected in series at the front end of the surge protection module.

• SPD is installed in parallel at the power supply inlet end of the building distribution box or the equipment room. The product is installed in the guide rail type. If conditions permit, the Kevin connection mode can be adopted.

• During installation, connect the device according to the installation diagram, where L is the phase line, N is the neutral line, and PE is the ground line. Do not misconnect the device. After the installation is complete, turn on the circuit breaker and check whether the working status is normal.

• When the SPD module is in use, check the status of the fault display window regularly. If the fault display window is red or the remote terminal outputs an alarm signal, it indicates that the SPD module is faulty and should be repaired or replaced in time.

• Suitable for indoor operation, if installed in the outdoor, must be equipped with waterproof box.

• All connections must be strong and reliable

 

KAMI DI SINI UNTUK MENDUKUNG ANDA!

Informasi lebih lanjut atau konsultasi pribadi? Produk dan pengetahuan kami hadir untuk memberikan solusi.

PRODUK TERKAIT
BERITA TERKAIT
ANDA MUNGKIN JUGA INGIN MELIHAT
DAPATKAN PERLINDUNGAN Lonjakan
SOLUSI HARI INI!
ikon
ikon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.