BR-12.5M 4P 12.5kA Tipe 1+2 Perangkat Pelindung Lonjakan Untuk TNS

Dapatkan Penawaran
Keterangan

Karakteristik produk:

Spesifikasi BR-12,5M 150 4P BR-12,5M 275 4P BR-12,5M 320 4P
Klasifikasi SPD menurut EN61643-11 Tipe 1 + Tipe 2 Tipe 1 + Tipe 2 Tipe 1 + Tipe 2
Klasifikasi SPD menurut IEC61643-11 Kelas I + Kelas II Kelas I + Kelas II Kelas I + Kelas II
Maks. operasi terus menerus a.c. voltase Uc 150V(50/60Hz) 275V(50/60Hz) 320V(50/60Hz)
Arus impuls petir (10/350μs) Imp 12,5kA 12,5kA 12,5kA
Arus pelepasan nominal (8/20μs) Di dalam 25kA 25kA 25kA
Maks. arus pelepasan (8/20μs) maksimal 60kA 60kA 60kA
Energi spesifik W/R 39kJ/Ω 39kJ/Ω 39kJ/Ω
Tingkat perlindungan tegangan Ke atas ≤0.8kV ≤1.3kV ≤1.5kV
Peringkat arus hubung singkat a.c. Isccr 25kA rms 25kA rms 25kA rms
Maks. sekering cadangan 125A gG 125A gG 125A gG
Tahan TOV tegangan lebih sementara UT(L-N) 180V/5sec. 335V/5sec. 400V/5sec.
Temporary overvoltage TOV-safe failure UT(L-N) 230V/120 menit. 440V/120 menit. 520V/120min.
Waktu respons ta ≤25ns ≤25ns ≤25ns
Kisaran suhu pengoperasian kamu -40℃-80℃ -40℃-80℃ -40℃-80℃
Status pengoperasian/indikasi kesalahan hijau/merah hijau/merah hijau/merah
Luas penampang (Min.) 4mm² 4mm² 4mm²
Luas penampang (Maks.) 35mm² 35mm² 35mm²
Untuk pemasangan Rel Din 35mm
Bahan penutup Termoplastik UL94-V0
Tingkat perlindungan IP20 IP20 IP20
Kode Pesanan B18411 B18413 B18415
Kode Pesanan (Dengan sinyal jarak jauh) B18412 B18414 B18416

Fitur:

Type 1+2, T1+T2, B+C, I+II, Iimp 12.5 kA is developed as the best solution available to protect service entrance at industrial sites.

It is designed to meet all your needs for any low voltage installation.

It is easy to install in any standardized distribution pane or control cabinets.

It has a 10/350 μs current waveform.

It is equipped with a thermal disconnection device and provide real-time fault indicators thus allowing complete operational safety.

Use the pluggable module set up, the maintenance is simple

Din rail mountable (35 mm)

It has the characteristics of low residual pressure, sensitive reaction, stable performance, reliable work and so on.

With remote signaling contact for control device.

It’s designed according to GB18802.1 IEC61643-11

Fault indication via red mark in the inspection window.

Aplikasi:

To prevent power supply equipment from being damaged by surge and lightning.

Use on buildings in applications where there is an external lightning protection system installed, usually installed at the service entrance.

Widely used in the transformer low-voltage side as the first protection of the power supply.

Instalasi:

Installed in low-voltage distributions at the boundary of LPZ 0–LPZ 1 zones and higher to prevent overvoltage effects induced during a lightning strike and to prevent switching overvoltage.

Install in the main distribution cabinet/box of the low-voltage cabinet and the incoming line cabinet.

Recommended for main distribution boards.

During installation, please connect according to the installation schematic diagram, where L1, L2 and L3 are phase lines, N is the zero line and PE is the ground line.

Grounding should conform to the requirements of the specification of lightning protection.

 

KAMI DI SINI UNTUK MENDUKUNG ANDA!

Informasi lebih lanjut atau konsultasi pribadi? Produk dan pengetahuan kami hadir untuk memberikan solusi.

PRODUK TERKAIT
BERITA TERKAIT
ANDA MUNGKIN JUGA INGIN MELIHAT
DAPATKAN PERLINDUNGAN Lonjakan
SOLUSI HARI INI!
ikon
ikon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator