BR-12.5M 3P 12.5kA Type 1+2 Surge Protective Device For TN-C

Dapatkan Penawaran
Keterangan

Karakteristik produk:

Spesifikasi BR-12,5M 150 3P BR-12,5M 275 3P BR-12,5M 320 3P
Klasifikasi SPD menurut EN61643-11 Tipe 1 + Tipe 2 Tipe 1 + Tipe 2 Tipe 1 + Tipe 2
Klasifikasi SPD menurut IEC61643-11 Kelas I + Kelas II Kelas I + Kelas II Kelas I + Kelas II
Maks. operasi terus menerus a.c. voltase Uc 150V(50/60Hz) 275V(50/60Hz) 320V(50/60Hz)
Arus impuls petir (10/350μs) Imp 12,5kA 12,5kA 12,5kA
Arus pelepasan nominal (8/20μs) Di dalam 25kA 25kA 25kA
Maks. arus pelepasan (8/20μs) maksimal 60kA 60kA 60kA
Energi spesifik W/R 39kJ/Ω 39kJ/Ω 39kJ/Ω
Tingkat perlindungan tegangan Ke atas ≤0.8kV ≤1.3kV ≤1.5kV
Peringkat arus hubung singkat a.c. Isccr 25kA rms 25kA rms 25kA rms
Maks. sekering cadangan 125A gG 125A gG 125A gG
Tahan TOV tegangan lebih sementara UT(L-N) 180V/5sec. 335V/5sec. 400V/5sec.
Temporary overvoltage TOV-safe failure UT(L-N) 230V/120 menit. 440V/120 menit. 520V/120min.
Waktu respons ta ≤25ns ≤25ns ≤25ns
Kisaran suhu pengoperasian kamu -40℃-80℃ -40℃-80℃ -40℃-80℃
Status pengoperasian/indikasi kesalahan hijau/merah hijau/merah hijau/merah
Luas penampang (Min.) 4mm² 4mm² 4mm²
Luas penampang (Maks.) 35mm² 35mm² 35mm²
Untuk pemasangan Rel Din 35mm
Bahan penutup Termoplastik UL94-V0
Tingkat perlindungan IP20 IP20 IP20
Kode Pesanan B18311 B18313 B18315
Kode Pesanan (Dengan sinyal jarak jauh) B18312 B18314 B18316

Fitur:

Britec hold patent for the design.

It adopts 35mm standard rail.

Time of response 25ns.

The plug-in module / base design facilitate replacement of a failed module without the need to remove system wiring etc.

There is a failure release mounted on the module of surge protective device.

It consists of a high performance varistor with thermal disconnection tripping device.

When the SPD fails in breakdown for over-heat and over-current, the failure release will help electric device separate from the power system and give the indication signal, green means normal, red means abnormal.

Aplikasi:

Used to guard sensitive equipment from voltage spike.

It is applied to low-voltage distribution system, which is connected in parallel between power supply and system equipment to protect the damage caused by instantaneous overvoltage caused by external (lightning

strike, electromagnetic radiation interference, etc.) or internal (system closing effect, induction and start and stop of capacitive load, etc.).

Instalasi:

Installed in low-voltage distributions at the boundary of LPZ 0–LPZ 1 zones and higher to prevent overvoltage effects induced during a lightning strike and to prevent switching overvoltage.

Install in the main distribution cabinet/box of the low-voltage cabinet and the incoming line cabinet.

Recommended for main distribution boards.

During installation, please connect according to the installation schematic diagram, where L1, L2 and L3 are phase lines, N is the zero line and PE is the ground line.

Grounding should conform to the requirements of the specification of lightning protection.

 

KAMI DI SINI UNTUK MENDUKUNG ANDA!

Informasi lebih lanjut atau konsultasi pribadi? Produk dan pengetahuan kami hadir untuk memberikan solusi.

PRODUK TERKAIT
BERITA TERKAIT
ANDA MUNGKIN JUGA INGIN MELIHAT
DAPATKAN PERLINDUNGAN Lonjakan
SOLUSI HARI INI!
ikon
ikon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.