Karakteristik produk:

Spesifikasi BR-12.5M 150 3P+N BR-12.5M 275 3P+N BR-12.5M 320 3P+N
Klasifikasi SPD menurut EN61643-11 Tipe 1 + Tipe 2 Tipe 1 + Tipe 2 Tipe 1 + Tipe 2
Klasifikasi SPD menurut IEC61643-11 Kelas I + Kelas II Kelas I + Kelas II Kelas I + Kelas II
Maks. operasi terus menerus a.c. voltase Uc(L-N/N-PE) 150V/255V(50/60Hz) 275V/255V(50/60Hz) 320V/255V(50/60Hz)
Arus impuls petir (10/350μs) Iimp(L-N/N-PE) 12.5kA/50kA 12.5kA/50kA 12.5kA/50kA
Arus pelepasan nominal (8/20μs) In(L-N/N-PE) 25kA/50kA 25kA/50kA 25kA/50kA
Maks. arus pelepasan (8/20μs) Imax(L-N/N-PE) 60kA/100kA 60kA/100kA 60kA/100kA
Energi spesifik W/R(L-N/N-PE) 39kJ/Ω, 625kJ/Ω 39kJ/Ω, 625kJ/Ω 339kJ/Ω, 625kJ/Ω
Tingkat perlindungan tegangan Up(L-N/N-PE) ≤0.8kV/≤1.5kV ≤1.3kV/≤1.5kV ≤1.5kV/≤1.5kV
Peringkat arus hubung singkat a.c. Isccr 25kA rms 25kA rms 25kA rms
Maks. sekering cadangan 125A gG 125A gG 125A gG
Tahan TOV tegangan lebih sementara UT(L-N) 180V/5sec. 335V/5sec. 400V/5sec.
Temporary overvoltage TOV-safe failure UT(L-N) 230V/120 menit. 440V/120 menit. 520V/120min.
Tahan TOV tegangan lebih sementara UT(N-PE) 1200V/200ms 1200V/200ms 1200V/200ms
Waktu respons tA(L-N/N-PE) ≤25ns/≤100ns ≤25ns/≤100ns ≤25ns/≤100ns
Kisaran suhu pengoperasian kamu -40℃-80℃ -40℃-80℃ -40℃-80℃
Status pengoperasian/indikasi kesalahan hijau/merah hijau/merah hijau/merah
Luas penampang (Min.) 4mm² 4mm² 4mm²
Luas penampang (Maks.) 35mm² 35mm² 35mm²
Untuk pemasangan Rel Din 35mm
Bahan penutup Termoplastik UL94-V0
Tingkat perlindungan IP20 IP20 IP20
Kode Pesanan B18611 B18613 B18615
Kode Pesanan (Dengan sinyal jarak jauh) B18612 B18614 B18616

Fitur:

New Iimp 12.5kA surge arrester.

Special design for saving installation space.

It protect to indirect and direct lightning effect or other transient over voltage

High discharge current.

SPD design according with GB18802.1/IEC61643-1 standard.

Indication window for clear display of SPD status, each pole with one indication window.

Number of poles: 3P+NPE.

Replaceable module.

Optional remote status signaling.

Aplikasi:

To prevent power supply equipment from being damaged by surge and lightning.

Use on buildings in applications where there is an external lightning protection system installed, usually installed at the service entrance.

Widely used in the transformer low-voltage side as the first protection of the power supply.

Instalasi:

Wiring according to the mark of surge protector according to the wiring diagram.

When installed according to the installation diagram shows the connection, where l (L1, L2, L3) for the line, n is neutral, PE ground wire, do not mistake. After the installation is complete, check that the protection unit is plugging in place, close the automatic circuit breaker (fuse) switch, check the working status is normal.

Protector in use during the fault display window should periodically verify and view state when red fault display window or remote Terminal outputs alarm signals, the protector fails, should be repaired or replaced in a timely manner.

 

KAMI DI SINI UNTUK MENDUKUNG ANDA!

Informasi lebih lanjut atau konsultasi pribadi? Produk dan pengetahuan kami hadir untuk memberikan solusi.

PRODUK TERKAIT
BERITA TERKAIT
ANDA MUNGKIN JUGA INGIN MELIHAT
DAPATKAN PERLINDUNGAN Lonjakan
SOLUSI HARI INI!
ikon
ikon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.