Karakteristik produk:

Spesifikasi BR-12,5M 150 2P BR-12,5M 275 2P BR-12,5M 320 2P
Klasifikasi SPD menurut EN61643-11 Tipe 1 + Tipe 2 Tipe 1 + Tipe 2 Tipe 1 + Tipe 2
Klasifikasi SPD menurut IEC61643-11 Kelas I + Kelas II Kelas I + Kelas II Kelas I + Kelas II
Maks. operasi terus menerus a.c. voltase Uc 150V(50/60Hz) 275V(50/60Hz) 320V(50/60Hz)
Arus impuls petir (10/350μs) Imp 12,5kA 12,5kA 12,5kA
Arus pelepasan nominal (8/20μs) Di dalam 25kA 25kA 25kA
Maks. arus pelepasan (8/20μs) maksimal 60kA 60kA 60kA
Energi spesifik W/R 39kJ/Ω 39kJ/Ω 39kJ/Ω
Tingkat perlindungan tegangan Ke atas ≤0.8kV ≤1.3kV ≤1.5kV
Peringkat arus hubung singkat a.c. Isccr 25kA rms 25kA rms 25kA rms
Maks. sekering cadangan 125A gG 125A gG 125A gG
Tahan TOV tegangan lebih sementara UT(L-N) 180V/5sec. 335V/5sec. 400V/5sec.
Temporary overvoltage TOV-safe failure UT(L-N) 230V/120 menit. 440V/120 menit. 520V/120min.
Waktu respons ta ≤25ns ≤25ns ≤25ns
Kisaran suhu pengoperasian kamu -40℃-80℃ -40℃-80℃ -40℃-80℃
Status pengoperasian/indikasi kesalahan hijau/merah hijau/merah hijau/merah
Luas penampang (Min.) 4mm² 4mm² 4mm²
Luas penampang (Maks.) 35mm² 35mm² 35mm²
Untuk pemasangan Rel Din 35mm
Bahan penutup Termoplastik UL94-V0
Tingkat perlindungan IP20 IP20 IP20
Kode Pesanan B18211 B18213 B18215
Kode Pesanan (Dengan sinyal jarak jauh) B18212 B18214 B18216

Fitur:

Type 1+2.

High discharge capacity in a certain small size.

High follow current extinction and limitation due to no follow current technology.

Reliable safety due to double integrated disconnections with double protections.

Failure indication window, remote alarm terminal optional.

Plug design, easy maintenance.

High security performance.

Green light in notice window indicates normal; red indicates broken, replacement notice, which is clear and easy distinguished.

Indoor fixed installation, voltage limited type.

Small volume, pluggable.

Aplikasi:

To prevent power supply equipment from being damaged by surge and lightning.

Use on buildings in applications where there is an external lightning protection system installed, usually installed at the service entrance.

Widely used in the transformer low-voltage side as the first protection of the power supply.

Instalasi:

Installed in low-voltage distributions at the boundary of LPZ 0–LPZ 1 zones and higher to prevent overvoltage effects induced during a lightning strike and to prevent switching overvoltage.

Install in the main distribution cabinet/box of the low-voltage cabinet and the incoming line cabinet.

Recommended for main distribution boards.

During installation, please connect according to the installation schematic diagram, where L1, L2 and L3 are phase lines, N is the zero line and PE is the ground line.

Grounding should conform to the requirements of the specification of lightning protection.

 

KAMI DI SINI UNTUK MENDUKUNG ANDA!

Informasi lebih lanjut atau konsultasi pribadi? Produk dan pengetahuan kami hadir untuk memberikan solusi.

PRODUK TERKAIT
BERITA TERKAIT
ANDA MUNGKIN JUGA INGIN MELIHAT
DAPATKAN PERLINDUNGAN Lonjakan
SOLUSI HARI INI!
ikon
ikon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.