BR-30FU 4P Type 2 30kA SPD

Λάβετε μια προσφορά
Περιγραφή

Χαρακτηριστικά προϊόντος:

Προσδιορισμός BR-30FU 150 4P BR-30FU 275 4P BR-30FU 320 4P BR-30FU 385 4P BR-30FU 440 4P
SPD classification according to EN61643-11 Τύπος 2 Τύπος 2 Τύπος 2 Τύπος 2 Τύπος 2
SPD classification according to IEC61643-11 Class II Class II Class II Class II Class II
Max. continuous operating a.c. voltage Uc 150V 275V 320V 385V 440V
Ονομαστικό ρεύμα εκφόρτισης (8/20μs) Σε 15kA 15kA 15kA 15kA 15kA
Μέγ. ρεύμα εκφόρτισης (8/20μs) Imax 30kA 30kA 30kA 30kA 30kA
Επίπεδο προστασίας τάσης Επάνω ≤0.8kV ≤1.3kV ≤1.5kV ≤1.8kV ≤2.0kV
Voltage protection level 5kA Επάνω ≤0.6kV ≤1kV ≤1.2kV ≤1.3kV ≤1.5kV
Short-circuit withstand capacity Isccr 25 kA 25 kA 25 kA 25 kA 25 kA
Temporary overvoltage TOV-withstand UT 180V/5sec. 335V/5sec. 400V/5sec. 500V/5sec. 580V/5sec.
Temporary overvoltage TOV-safe failure UT 230V/120min. 440V/120min. 520V/120min. 650V/120min. 765V/120min.
Χρόνος απόκρισης tA ≤25ns ≤25ns ≤25ns ≤25ns ≤25ns
Εύρος θερμοκρασίας λειτουργίας Tu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red green/red green/red
Εμβαδόν διατομής (ελάχ.) 4mm² 4mm² 4mm² 4mm² 4mm²
Εμβαδόν διατομής (Μέγ.) 35 mm² 35 mm² 35 mm² 35 mm² 35 mm²
Για τοποθέτηση σε Ράγα Din 35mm
Υλικό περιβλήματος Thermoplastic   UL94-V0
Βαθμός προστασίας IP20 IP20 IP20 IP20 IP20
Order Code B16106 B16118 B16130 B16142 B16154
Order Code (With remote signaling) B16107 B16119 B16131 B16143 B16155

Χαρακτηριστικά:

The surge arrestors BR-30FU meet the type 2 requirement class according to IEC 61643-11.

35mm electrical lead rail installation

Surge protective device, plug.

8/20us wave form, low residual voltage

Remote signaling port, remote alert

Hot melt flow double protection.

Connectable surge arrestor

The reaction time of less than 25 ns.

High arresting capacity

Visual status display

The maximum discharging currents (IMAX 8/20) of each line could be 30kA.

Labelled connections

Εφαρμογή:

Type 2 Surge Arresters provide protection against overvoltage originating from switching and the secondary effects of lightning strikes.

In order to shunt and pressure to limit indirect lightning current or other instantaneous overvoltage.

Floor distribution box of buildings

Εγκατάσταση:

• The type 2 arresters must install into sub-distribution boards after main distribution boards containing type 1 arresters.

• For proper operation between type 1 and type 2 arresters at least 10- 15 m cable or wire must be otherwise a decoupling coil have to install between the two devices.

• In areas where storms are frequent, it is strongly recommended to install additional protection systems.
ΕΙΜΑΣΤΕ ΕΔΩ ΓΙΑ ΝΑ ΣΑΣ ΥΠΟΣΤΗΡΙΞΟΥΜΕ!

Περισσότερες πληροφορίες ή προσωπική διαβούλευση; Τα προϊόντα και η τεχνογνωσία μας υπάρχουν για να δώσουν λύσεις.

ΣΧΕΤΙΚΑ ΠΡΟΪΟΝΤΑ
ΣΧΕΤΙΚΑ ΝΕΑ
ΜΠΟΡΕΙ ΕΠΙΣΗΣ ΝΑ ΘΕΛΕΤΕ ΝΑ ΔΕΙΤΕ
ΑΠΟΚΤΗΣΤΕ ΤΗΝ ΠΡΟΣΤΑΣΙΑ ΑΠΟ ΤΥΠΟΥΣ
ΛΥΣΗ ΣΗΜΕΡΑ!
εικόνισμα
εικόνισμα
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.