BR-80 2P Type 2 80kA Surge Protective Device For TNS

Holen Sie sich ein Zitat
Beschreibung

Produkteigenschaften:

Spezifikation BR-80 150 2P BR-80 275 2P BR-80 320 2P BR-80 385 2P
SPD-Klassifizierung gemäß EN61643-11 Typ 2 Typ 2 Typ 2 Typ 2
SPD-Klassifizierung gemäß IEC61643-11 Class II Class II Class II Class II
Max. Dauerbetrieb mit Wechselstrom Stromspannung Uc 150V 275V 320V 385V
Nominal discharge current (8/20μs) In 40kA 40kA 40kA 40kA
Max. discharge current (8/20μs) Imax 80kA 80kA 80kA 80kA
Spannungsschutzniveau Hoch ≤1.0kV ≤1.7kV ≤2.0kV ≤2.3kV
Voltage protection level 5kA Hoch ≤0.6kV ≤1.0kV ≤1.1kV ≤1.2kV
Max. backup fuse 160A gG 160A gG 160A gG 160A gG
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA
Temporary overvoltage TOV-withstand UT 180V/5sec. 335V/5sec. 400V/5sec. 500V/5sec.
Temporary overvoltage TOV-safe failure UT 230V/120min. 440V/120min. 520V/120min. 650V/120min.
Ansprechzeit tA ≤25ns ≤25ns ≤25ns ≤25ns
Betriebstemperaturbereich Di -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red green/red
Cross-section area (Min.) 4mm² 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm² 35mm²
Zur Montage 35mm Din rail
Gehäusematerial Thermoplastic   UL94-V0
Schutzart IP20 IP20 IP20 IP20
Bestellcode B18276 B18278 B18280 B18282
Order Code (With remote signaling) B18277 B18279 B18281 B18283

Merkmale:

Class II, Type 2, 80kA 2P.

Discharge currents : In : 40 kA / Imax : 80 kA.

IEC 61643-11 and EN 61643-11 compliance.

BR-80 is DIN rail compatible and is built with a plug-in module and a fixed base.

The BR-80 protects against the direct and indirect lightning strikes and large switching transients.

They are particularly useful in areas where space is limited.

Version with a remote signaling for disconnection indication is also available.

Anwendung:

Widely appreciated for its high level of protection, efficiency, and reliable performance, these single phase surge protectors are vastly used for protecting electrical devices such as computers, TVs, and other devices.

Application in industrial plants, commercial buildings, institutional facilities, and corporate offices.

For use in the Lightning Protection Zones Concept at the boundaries of LPZ 1-2 (according to IEC 1312-1 and EN62305).

 

WIR SIND DA, UM SIE ZU UNTERSTÜTZEN!

Weitere Informationen oder eine persönliche Beratung? Unsere Produkte und unser Know-how sind da, um Lösungen anzubieten.

VERWANDTE PRODUKTE
VERWANDTE NACHRICHTEN
Vielleicht möchten Sie es auch sehen
ERHALTEN SIE ÜBERSPANNUNGSSCHUTZ
LÖSUNGEN HEUTE!
Symbol
Symbol
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.