Produkteigenschaften:

Spezifikation BR-60 150 3+1 BR-60 275 3+1 BR-60 320 3+1 BR-60 385 3+1
SPD-Klassifizierung gemäß EN61643-11 Typ 2 Typ 2 Typ 2 Typ 2
SPD-Klassifizierung gemäß IEC61643-11 Class II Class II Class II Class II
Max. continuous operating a.c. voltage(L-N) Uc 150V 275V 320V 385V
Max. continuous operating a.c. voltage(N-PE) Uc 255V 255V 255V 255V
Nominal discharge current (8/20μs) In 30kA 30kA 30kA 30kA
Max. discharge current (8/20μs) Imax 60kA 60kA 60kA 60kA
Voltage protection level (L-N) Hoch ≤1.0kV ≤1.6kV ≤1.8kV ≤2.2kV
Voltage protection level 5kA (L-N) Hoch ≤0.5kV ≤0.6kV ≤1.0kV ≤1.2kV
Voltage protection level (N-PE) Hoch ≤1.5kV ≤1.5kV ≤1.5kV ≤1.5kV
Max. backup fuse 160A gG 160A gG 160A gG 160A gG
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA
Temporary overvoltage TOV-withstand (L-N) UT 180V/5sec. 335V/5sec. 400V/5sec. 500V/5sec.
Temporary overvoltage TOV-safe failure (L-N) UT 230V/120min. 440V/120min. 520V/120min. 650V/120min.
Temporary overvoltage TOV-withstand (N-PE) UT 1200V/200ms 1200V/200ms 1200V/200ms 1200V/200ms
Response time (L-N) tA ≤25ns ≤25ns ≤25ns ≤25ns
Response time (N-PE) tA ≤100ns ≤100ns ≤100ns ≤100ns
Betriebstemperaturbereich Di -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red green/red
Cross-section area (Min.) 4mm² 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm² 35mm²
Zur Montage 35mm Din rail
Gehäusematerial Thermoplastic   UL94-V0
Schutzart IP20 IP20 IP20 IP20
Bestellcode B18801 B18803 B18805 B18807
Order Code (With remote signaling) B18802 B18804 B18806 B18808

Merkmale:

Indoor fixed installation, voltage limited type.

Voltage-limiting SPD SPD using voltage-limiting components such as varistor (MOV).

The product shall comply with the standard of GB 18802.1 / IEC 61643-11

Adopts 35mm standard rail.

When the SPD works normally, the visible window displays green, and when it fails, it displays red.

Anwendung:

The series protects as well private home as industrial equipment, and radio base stations.

Lightning strikes create surge currents which generate over voltages in the power distribution and data transmission networks. The surge protective devices divert the surge current harmlessly to the ground and limit

overvoltage to values compatible with the equipment connected to the network.

 

WIR SIND DA, UM SIE ZU UNTERSTÜTZEN!

Weitere Informationen oder eine persönliche Beratung? Unsere Produkte und unser Know-how sind da, um Lösungen anzubieten.

VERWANDTE PRODUKTE
VERWANDTE NACHRICHTEN
Vielleicht möchten Sie es auch sehen
ERHALTEN SIE ÜBERSPANNUNGSSCHUTZ
LÖSUNGEN HEUTE!
Symbol
Symbol
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.