BR-50GR 3+1 Type 1 50kA Surge Arrester for TT and TNS

Holen Sie sich ein Zitat
Beschreibung

Produkteigenschaften:

Spezifikation BR-50GR 150 3+1 BR-50GR 275 3+1 BR-50GR 350 3+1
SPD-Klassifizierung gemäß EN61643-11 Type 1 + Type 2 Type 1 + Type 2 Type 1 + Type 2
SPD-Klassifizierung gemäß IEC61643-11 Class I + Class II Class I + Class II Class I + Class II
Nominal operating voltage Un 120V/240V(50/60Hz) 230V/400V(50/60Hz) 250V/440V(50/60Hz)
Max. Dauerbetrieb mit Wechselstrom Stromspannung Uc (L-N/N-PE) 150V/255V(50/60Hz) 275V/255V(50/60Hz) 350V/255V(50/60Hz)
Lightning impulse current (10/350μs) Iimp (L-N/N-PE) 50kA/100kA 50kA/100kA 50kA/100kA
Nominal discharge current (8/20μs) In (L-N/N-PE) 50kA/100kA 50kA/100kA 50kA/100kA
Max. discharge current (8/20μs) Imax (L-N/N-PE) 160kA/200kA 160kA/200kA 160kA/200kA
Quantity of electric charge (L-N, N-PE) Q 25As, 50As 25As, 50As 25As, 50As
Specific energy (L-N, N-PE) W/R 625kJ/Ω, 2500kJ/Ω 625kJ/Ω, 2500kJ/Ω 625kJ/Ω, 2500kJ/Ω
Spannungsschutzniveau Up (L-N/N-PE) ≤1.5kV/≤1.5kV ≤1.5kV/≤1.5kV ≤1.5kV/≤1.5kV
Short-circuit current rating a.c. Isccr (L-N/N-PE) 25kA rms/100A rms 25kA rms/100A rms 25kA rms/100A rms
Max. backup fuse 350A gG 350A gG 350A gG
Temporary overvoltage TOV-withstand UT (L-N) 230V/120min. 440V/120min. 580V/120min.
Temporary overvoltage TOV-withstand UT (N-PE) 1200V/200ms 1200V/200ms 1200V/200ms
Ansprechzeit tA ≤100ns ≤100ns ≤100ns
Betriebstemperaturbereich Di -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red
Cross-section area (Min.) 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm²
Zur Montage 35mm Din rail
Gehäusematerial Thermoplast UL94-V0
Schutzart IP20 IP20 IP20
Bestellcode B17166 B18167 B17192
Order Code (With remote signaling) B17167 B18168 B17193

Merkmale:

Endurable, sustains multiple strikes.

LED status indication.

Protection class: Type 1+2, Class I +Class II.

BR-50GR 3P+N is suitable for TT and TN-S system.

Anwendung:

● Suitable for TT and TN-S system.

● Used in industrial systems and buildings with external lightning protection of Classes I to IV.

● For the protection of low voltage distribution systems against direct lightning strike into the overhead power supply line or external lightning protection system.

● Can be used in standard distributor housing.

● Used to protect all kinds of electrical equipment in the power system from lightning over-voltage, operation over-voltage, power frequency transient over-voltage impact damage to an electrical appliance.

 

WIR SIND DA, UM SIE ZU UNTERSTÜTZEN!

Weitere Informationen oder eine persönliche Beratung? Unsere Produkte und unser Know-how sind da, um Lösungen anzubieten.

VERWANDTE PRODUKTE
VERWANDTE NACHRICHTEN
Vielleicht möchten Sie es auch sehen
ERHALTEN SIE ÜBERSPANNUNGSSCHUTZ
LÖSUNGEN HEUTE!
Symbol
Symbol
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.