Produkteigenschaften:
| Spezifikation | BR-40 150 1+1 | BR-40 275 1+1 | BR-40 320 1+1 | BR-40 385 1+1 | BR-40 440 1+1 | |
| SPD-Klassifizierung gemäß EN61643-11 | Typ 2 | Typ 2 | Typ 2 | Typ 2 | Typ 2 | |
| SPD-Klassifizierung gemäß IEC61643-11 | Class II | Class II | Class II | Class II | Class II | |
| Max. continuous operating a.c. voltage(L-N) | Uc | 150V | 275V | 320V | 385V | 440V |
| Max. continuous operating a.c. voltage(N-PE) | Uc | 255V | 255V | 255V | 255V | 255V |
| Nominal discharge current (8/20μs) | In | 20kA | 20kA | 20kA | 20kA | 20kA |
| Max. discharge current (8/20μs) | Imax | 40kA | 40kA | 40kA | 40kA | 40kA |
| Voltage protection level (L-N) | Hoch | ≤0.8kV | ≤1,3 kV | ≤1.5kV | ≤1.8kV | ≤2.0kV |
| Voltage protection level 5kA (L-N) | Hoch | ≤0.6kV | ≤1kV | ≤1.2kV | ≤1,3 kV | ≤1.5kV |
| Voltage protection level (N-PE) | Hoch | ≤1.5kV | ≤1.5kV | ≤1.5kV | ≤1.5kV | ≤1.5kV |
| Max. backup fuse | 100A gG | 100A gG | 100A gG | 100A gG | 100A gG | |
| Short-circuit withstand capacity | Isccr | 25kA | 25kA | 25kA | 25kA | 25kA |
| Temporary overvoltage TOV-withstand (L-N) | UT | 180V/5sec. | 335V/5sec. | 400V/5sec. | 500V/5sec. | 580V/5sec. |
| Temporary overvoltage TOV-safe failure(L-N) | UT | 230V/120min. | 440V/120min. | 520V/120min. | 650V/120min. | 765V/120min. |
| Temporary overvoltage TOV-withstand(N-PE) | UT | 1200V/200ms | 1200V/200ms | 1200V/200ms | 1200V/200ms | 1200V/200ms |
| Response time (L-N) | tA | ≤25ns | ≤25ns | ≤25ns | ≤25ns | ≤25ns |
| Response time (N-PE) | tA | ≤100ns | ≤100ns | ≤100ns | ≤100ns | ≤100ns |
| Betriebstemperaturbereich | Di | -40℃-80℃ | -40℃-80℃ | -40℃-80℃ | -40℃-80℃ | -40℃-80℃ |
| Operating state/fault indication | green/red | green/red | green/red | green/red | green/red | |
| Cross-section area (Min.) | 4mm² | 4mm² | 4mm² | 4mm² | 4mm² | |
| Cross-section area (Max.) | 35mm² | 35mm² | 35mm² | 35mm² | 35mm² | |
| Zur Montage | 35mm Din rail | |||||
| Gehäusematerial | Thermoplastic UL94-V0 | |||||
| Schutzart | IP20 | IP20 | IP20 | IP20 | IP20 | |
| Bestellcode | B18251 | B18253 | B18255 | B18257 | B18370 | |
| Order Code (With remote signaling) | B18252 | B18254 | B18256 | B18258 | B18371 | |
Merkmale:
Lightning surge protector with compact construction design
35mm2 DIN-rail in accordance with EN 50022/DIN46277-3
Application systems: TT, IT, and TN power supply system.
Protection mode: L-N, N-PE.
40kA Type 2 Class C AC Surge Protection Device.
Our offered surge protector is designed by utilizing the top grade material and the most advanced techniques.
Reliable control thanks to Thermo Dynamic Control disconnector.
Anwendung:
For protection of consumer equipment against transient voltage caused by indirect lightning strike and switching operations.
Use in domestic, commercial and light industrial installations.
Usually installed in household power distribution boards, telecom machinery center, computer equipment center, elevator control center, hospital’s surgery and ICU, information equipment, electronic equipment and in front of control equipment or nearest socket box of control equipment.
Installation:
Usually installed in the distribution box office, the power phase line (L), neutral (N), respectively, corresponding surge protectors access terminals to ensure secure and reliable, and the surge protector ground terminal and ground as well electrical connection.
It should regularly check the work, such as the window turns red indicating the deterioration of its front open space, when the fuse is tripped, timely maintenance or replacement module.
After the installation is complete, check that the protection unit is plug in place, close the automatic circuit breaker (fuse) switch, check the working status is normal.
Weitere Informationen oder eine persönliche Beratung? Unsere Produkte und unser Know-how sind da, um Lösungen anzubieten.