BR-30FU 4P Typ 2 30kA SPD

Holen Sie sich ein Zitat
Beschreibung

Produkteigenschaften:

Spezifikation BR-30FU 150 4P BR-30FU 275 4P BR-30FU 320 4P BR-30FU 385 4P BR-30FU 440 4P
SPD-Klassifizierung gemäß EN61643-11 Typ 2 Typ 2 Typ 2 Typ 2 Typ 2
SPD-Klassifizierung gemäß IEC61643-11 Class II Class II Class II Class II Class II
Max. Dauerbetrieb mit Wechselstrom Stromspannung Uc 150V 275V 320V 385V 440V
Nominal discharge current (8/20μs) In 15kA 15kA 15kA 15kA 15kA
Max. discharge current (8/20μs) Imax 30kA 30kA 30kA 30kA 30kA
Spannungsschutzniveau Hoch ≤0.8kV ≤1,3 kV ≤1.5kV ≤1.8kV ≤2.0kV
Voltage protection level 5kA Hoch ≤0.6kV ≤1kV ≤1.2kV ≤1,3 kV ≤1.5kV
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA 25kA
Temporary overvoltage TOV-withstand UT 180V/5sec. 335V/5sec. 400V/5sec. 500V/5sec. 580V/5sec.
Temporary overvoltage TOV-safe failure UT 230V/120min. 440V/120min. 520V/120min. 650V/120min. 765V/120min.
Ansprechzeit tA ≤25ns ≤25ns ≤25ns ≤25ns ≤25ns
Betriebstemperaturbereich Di -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red green/red green/red
Cross-section area (Min.) 4mm² 4mm² 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm² 35mm² 35mm²
Zur Montage 35mm Din rail
Gehäusematerial Thermoplastic   UL94-V0
Schutzart IP20 IP20 IP20 IP20 IP20
Bestellcode B16106 B16118 B16130 B16142 B16154
Order Code (With remote signaling) B16107 B16119 B16131 B16143 B16155

Merkmale:

The surge arrestors BR-30FU meet the type 2 requirement class according to IEC 61643-11.

35mm electrical lead rail installation

Surge protective device, plug.

8/20us wave form, low residual voltage

Remote signaling port, remote alert

Hot melt flow double protection.

Connectable surge arrestor

The reaction time of less than 25 ns.

High arresting capacity

Visual status display

The maximum discharging currents (IMAX 8/20) of each line could be 30kA.

Labelled connections

Anwendung:

Type 2 Surge Arresters provide protection against overvoltage originating from switching and the secondary effects of lightning strikes.

In order to shunt and pressure to limit indirect lightning current or other instantaneous overvoltage.

Floor distribution box of buildings

Installation:

• The type 2 arresters must install into sub-distribution boards after main distribution boards containing type 1 arresters.

• For proper operation between type 1 and type 2 arresters at least 10- 15 m cable or wire must be otherwise a decoupling coil have to install between the two devices.

• In areas where storms are frequent, it is strongly recommended to install additional protection systems.
WIR SIND DA, UM SIE ZU UNTERSTÜTZEN!

Weitere Informationen oder eine persönliche Beratung? Unsere Produkte und unser Know-how sind da, um Lösungen anzubieten.

VERWANDTE PRODUKTE
VERWANDTE NACHRICHTEN
Vielleicht möchten Sie es auch sehen
ERHALTEN SIE ÜBERSPANNUNGSSCHUTZ
LÖSUNGEN HEUTE!
Symbol
Symbol
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.