BR-25GS 1P+N Type 1+2 25kA Surge Arrester For TT And TNS

Holen Sie sich ein Zitat
Beschreibung

Produkteigenschaften:

Spezifikation BR-25GS 150 1P+N BR-25GS 275 1P+N BR-25GS 320 1P+N
SPD-Klassifizierung gemäß EN61643-11 Type 1 + Type 2 Type 1 + Type 2 Type 1 + Type 2
SPD-Klassifizierung gemäß IEC61643-11 Class I + Class II Class I + Class II Class I + Class II
Nominal operating a.c. voltage Un 120V/240V(50/60Hz) 230V/400V(50/60Hz) 240V/415V(50/60Hz)
Max. Dauerbetrieb mit Wechselstrom Stromspannung Uc (L-N/N-PE) 150V/255V(50/60Hz) 275V/255V(50/60Hz) 320V/255V(50/60Hz)
Lightning impulse current (10/350μs) Iimp (L-N/N-PE) 25kA/50kA 25kA/50kA 25kA/50kA
Nominal discharge current (8/20μs) In (L-N/N-PE) 25kA/50kA 25kA/50kA 25kA/50kA
Max. discharge current (8/20μs) Imax (L-N/N-PE) 100kA/120kA 100kA/120kA 100kA/120kA
Quantity of electric charge Q (L-N/N-PE) 12.5As/25As 12.5As/25As 12.5As/25As
Specific energy W/R (L-N/N-PE) 156kJ/Ω, 625kJ/Ω 156kJ/Ω, 625kJ/Ω 156kJ/Ω, 625kJ/Ω
Spannungsschutzniveau Up (L-N/N-PE) ≤1.5kV/≤1.5kV ≤1.5kV/≤1.5kV ≤1.5kV/≤1.5kV
Max. backup fuse 200A gG 200A gG 200A gG
Short-circuit current rating a.c. Isccr 25kA 25kA 25kA
Follow current extinguishing capability a.c. Ifi (L-N/N-PE) 25kA/100A 25kA/100A 25kA/100A
Temporary overvoltage TOV-withstand UT (L-N) 230V/120min. 440V/120min. 580V/120min.
Temporary overvoltage TOV-withstand UT (N-PE) 1200V/200ms 1200V/200ms 1200V/200ms
Ansprechzeit tA ≤100ns ≤100ns ≤100ns
Leakage current Ipe <0.1mA <0.1mA <0.1mA
Betriebstemperaturbereich Di -40℃-85℃ -40℃-85℃ -40℃-85℃
Operating state/fault indication green/red green/red green/red
Cross-section area (Min.) 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm²
Zur Montage 35mm Din rail
Gehäusematerial Thermoplast UL94-V0
Schutzart IP20 IP20 IP20
Bestellcode B17060 B17073 B17098
Order Code (With remote signaling) B17061 B17074 B17099
Suffixes: Add Suffix “RS” for dry contact remote signaling version. Example: BR-25GS 275 1P+N RS

Merkmale:

Remote signalling available.

35mm wide electrical installation guide rail.

Simple and easy to use. More reliable and more safety.

Surge protect, prevents home electric network receive excessive impact while lightning.

Number of poles: 1P+N

Anwendung:

For protecting low voltage equipment from surge damages.

This products is especially suitable for application in the A grade lightning protection in high risk area of lightning strike.

Suitable for indoor operation, if installed in the outdoor, must be equipped with waterproof shell.

It is mainly used for the first stage of lightning surge overvoltage protection in AC distribution system.

Used to protect electrical and electronic equipment from lightning electromagnetic pulse induced voltages, operating transients and overvoltages.

Widely used in communication equipment, power, security, traffic, industrial control and other fields of power protection.

Distribution box with overhead input in building.

Installation:

Installations more than 10 m high (apartment buildings, office buildings, hotels, etc.): type 2 SPD recommended for protecting private areas and floor distributors (communal areas) in addition to a type 1 or type 1+2 SPDs.

SCHEMAS

WIR SIND DA, UM SIE ZU UNTERSTÜTZEN!

Weitere Informationen oder eine persönliche Beratung? Unsere Produkte und unser Know-how sind da, um Lösungen anzubieten.

VERWANDTE PRODUKTE
VERWANDTE NACHRICHTEN
Vielleicht möchten Sie es auch sehen
ERHALTEN SIE ÜBERSPANNUNGSSCHUTZ
LÖSUNGEN HEUTE!
Symbol
Symbol
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.