BR-12.5M 3P+N 12.5kA Type 1+2 Surge Protective Device For TT And TNS

Holen Sie sich ein Zitat
Beschreibung

Produkteigenschaften:

Spezifikation BR-12.5M 150 3P+N BR-12.5M 275 3P+N BR-12.5M 320 3P+N
SPD-Klassifizierung gemäß EN61643-11 Type 1 + Type 2 Type 1 + Type 2 Type 1 + Type 2
SPD-Klassifizierung gemäß IEC61643-11 Class I + Class II Class I + Class II Class I + Class II
Max. Dauerbetrieb mit Wechselstrom Stromspannung Uc(L-N/N-PE) 150V/255V(50/60Hz) 275V/255V(50/60Hz) 320V/255V(50/60Hz)
Lightning impulse current (10/350μs) Iimp(L-N/N-PE) 12.5kA/50kA 12.5kA/50kA 12.5kA/50kA
Nominal discharge current (8/20μs) In(L-N/N-PE) 25kA/50kA 25kA/50kA 25kA/50kA
Max. discharge current (8/20μs) Imax(L-N/N-PE) 60kA/100kA 60kA/100kA 60kA/100kA
Specific energy W/R(L-N/N-PE) 39kJ/Ω, 625kJ/Ω 39kJ/Ω, 625kJ/Ω 339kJ/Ω, 625kJ/Ω
Spannungsschutzniveau Up(L-N/N-PE) ≤0.8kV/≤1.5kV ≤1.3kV/≤1.5kV ≤1.5kV/≤1.5kV
Short-circuit current rating a.c. Isccr 25kA rms 25kA rms 25kA rms
Max. backup fuse 125A gG 125A gG 125A gG
Temporary overvoltage TOV-withstand UT(L-N) 180V/5sec. 335V/5sec. 400V/5sec.
Temporary overvoltage TOV-safe failure UT(L-N) 230V/120min. 440V/120min. 520V/120min.
Temporary overvoltage TOV-withstand UT(N-PE) 1200V/200ms 1200V/200ms 1200V/200ms
Ansprechzeit tA(L-N/N-PE) ≤25ns/≤100ns ≤25ns/≤100ns ≤25ns/≤100ns
Betriebstemperaturbereich Di -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red
Cross-section area (Min.) 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm²
Zur Montage 35mm Din rail
Gehäusematerial Thermoplast UL94-V0
Schutzart IP20 IP20 IP20
Bestellcode B18611 B18613 B18615
Order Code (With remote signaling) B18612 B18614 B18616

Merkmale:

New Iimp 12.5kA surge arrester.

Special design for saving installation space.

It protect to indirect and direct lightning effect or other transient over voltage

High discharge current.

SPD design according with GB18802.1/IEC61643-1 standard.

Indication window for clear display of SPD status, each pole with one indication window.

Number of poles: 3P+NPE.

Replaceable module.

Optional remote status signaling.

Anwendung:

To prevent power supply equipment from being damaged by surge and lightning.

Use on buildings in applications where there is an external lightning protection system installed, usually installed at the service entrance.

Widely used in the transformer low-voltage side as the first protection of the power supply.

Installation:

Wiring according to the mark of surge protector according to the wiring diagram.

When installed according to the installation diagram shows the connection, where l (L1, L2, L3) for the line, n is neutral, PE ground wire, do not mistake. After the installation is complete, check that the protection unit is plugging in place, close the automatic circuit breaker (fuse) switch, check the working status is normal.

Protector in use during the fault display window should periodically verify and view state when red fault display window or remote Terminal outputs alarm signals, the protector fails, should be repaired or replaced in a timely manner.

 

WIR SIND DA, UM SIE ZU UNTERSTÜTZEN!

Weitere Informationen oder eine persönliche Beratung? Unsere Produkte und unser Know-how sind da, um Lösungen anzubieten.

VERWANDTE PRODUKTE
VERWANDTE NACHRICHTEN
Vielleicht möchten Sie es auch sehen
ERHALTEN SIE ÜBERSPANNUNGSSCHUTZ
LÖSUNGEN HEUTE!
Symbol
Symbol
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.