BR-12.5M 1P+N 12.5kA Type 1+2 Surge Protective Device For TT And TNS

Holen Sie sich ein Zitat
Beschreibung

Produkteigenschaften:

Spezifikation BR-12.5M 150 1P+N BR-12.5M 275 1P+N BR-12.5M 320 1P+N
SPD-Klassifizierung gemäß EN61643-11 Type 1 + Type 2 Type 1 + Type 2 Type 1 + Type 2
SPD-Klassifizierung gemäß IEC61643-11 Class I + Class II Class I + Class II Class I + Class II
Max. Dauerbetrieb mit Wechselstrom Stromspannung Uc(L-N/N-PE) 150V/255V(50/60Hz) 275V/255V(50/60Hz) 320V/255V(50/60Hz)
Lightning impulse current (10/350μs) Iimp(L-N/N-PE) 12.5kA/25kA 12.5kA/25kA 12.5kA/25kA
Nominal discharge current (8/20μs) In(L-N/N-PE) 25kA/50kA 25kA/50kA 25kA/50kA
Max. discharge current (8/20μs) Imax(L-N/N-PE) 60kA/100kA 60kA/100kA 60kA/100kA
Specific energy W/R(L-N/N-PE) 39kJ/Ω, 156kJ/Ω 39kJ/Ω, 156kJ/Ω 339kJ/Ω, 156kJ/Ω
Spannungsschutzniveau Up(L-N/N-PE) ≤0.8kV/≤1.5kV ≤1.3kV/≤1.5kV ≤1.5kV/≤1.5kV
Short-circuit current rating a.c. Isccr 25kA rms 25kA rms 25kA rms
Max. backup fuse 125A gG 125A gG 125A gG
Temporary overvoltage TOV-withstand UT(L-N) 180V/5sec. 335V/5sec. 400V/5sec.
Temporary overvoltage TOV-safe failure UT(L-N) 230V/120min. 440V/120min. 520V/120min.
Temporary overvoltage TOV-withstand UT(N-PE) 1200V/200ms 1200V/200ms 1200V/200ms
Ansprechzeit tA(L-N/N-PE) ≤25ns/≤100ns ≤25ns/≤100ns ≤25ns/≤100ns
Betriebstemperaturbereich Di -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red
Cross-section area (Min.) 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm²
Zur Montage 35mm Din rail
Gehäusematerial Thermoplast UL94-V0
Schutzart IP20 IP20 IP20
Bestellcode B18617 B18619 B18621
Order Code (With remote signaling) B18618 B18620 B18622

Merkmale:

Modular and plug-in arrestor.

Type 1+2 surge arrestor according to EN 61643-11.

Lightning current arresting capacity 12.5 kA (10/350us) per pole.

Operating state / fault indication by green / red indicator flag in the inspection window.

Remote signaling can be selectable.

Universally suitable for TT systems.

Anwendung:

For general protection of big installations and protection of small installations with external lightning protection.

Installation:

Before installation, it should be check whether the surge protector is intact. If it is damaged or the display window is red, it cannot be used; if the window is green, it is normal.

 

WIR SIND DA, UM SIE ZU UNTERSTÜTZEN!

Weitere Informationen oder eine persönliche Beratung? Unsere Produkte und unser Know-how sind da, um Lösungen anzubieten.

VERWANDTE PRODUKTE
VERWANDTE NACHRICHTEN
Vielleicht möchten Sie es auch sehen
ERHALTEN SIE ÜBERSPANNUNGSSCHUTZ
LÖSUNGEN HEUTE!
Symbol
Symbol
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.