{"id":750,"date":"2023-12-19T20:39:19","date_gmt":"2023-12-19T12:39:19","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=750"},"modified":"2024-09-05T16:35:09","modified_gmt":"2024-09-05T08:35:09","slug":"how-surge-protection-devices-protect-photovoltaic-plants","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/tr\/blog\/how-surge-protection-devices-protect-photovoltaic-plants\/","title":{"rendered":"A\u015f\u0131r\u0131 Gerilim Koruma Cihazlar\u0131 fotovoltaik tesisleri nas\u0131l korur?"},"content":{"rendered":"<strong>PV tesislerinde SPD'lerin s\u00fcrekli \u00e7al\u0131\u015fmay\u0131 ve enerji \u00fcretimini sa\u011flamak i\u00e7in \u00f6zel gereksinimleri kar\u015f\u0131lamas\u0131 gerekir.<\/strong>\r\n\r\nBir PV tesisi tasarlarken a\u015f\u0131r\u0131 gerilim koruma cihazlar\u0131n\u0131n (SPD'ler) kurulumunu dikkate almak \u00f6nemlidir. Dalgalanmalar ve a\u011f kesintileri tesisin performans\u0131n\u0131 d\u00fc\u015f\u00fcrerek kesintilere neden olabilir. Bu nedenle elektrik tesisat\u0131 tasarlan\u0131rken enerji \u00fcretimini ve da\u011f\u0131t\u0131m\u0131n\u0131 etkileyen her t\u00fcrl\u00fc ko\u015ful dikkate al\u0131nmal\u0131d\u0131r.\r\n\r\n<strong>PV santrallerinde SPD'ler neden en \u00f6nemli \u00f6nceliktir?<\/strong>\r\n\r\nSolar panels are installed outside to convert solar energy into electricity. This outdoor location makes them directly exposed to harsh conditions like rain, wind and dust. Among the weather conditions lightning strikes require specific attention as they can severely affect the safety and performance of a PV plant. They originate in a cumulonimbus cloud and terminate on the ground. When the lightning strike hits the ground, it discharges energy, affecting the electrical field on the ground. For the solar PV plant this poses two risks:\r\n\r\nA direct impact which can physically destroy the solar equipment on a rooftop\r\n\r\nTransitory over voltages passing through cables by magnetic coupling, which can lead to the damage of sensitive components such as printed circuit boards (PCB).\r\n\r\nAs far as the direct impact is concerned, \u2018External Lightning Protects\u2019 (ELP) provide the required protection according to IEC 62305, which describes how to evaluate if your location needs such protection, and what should be the preferred option (meshed cages, air terminal, etc.). The concept is simple: make sure the lightning will strike a metallic rod installed on the highest point of your plant and dispel the energy directly to the ground through a copper down conductor.\r\n\r\nWhen it comes to transitory over voltages, however, SPDs are required. They are installed in parallel into the circuit protection boards to divert the energy to the ground and limit the overvoltage up to such value acceptable to the end equipment.\r\n\r\nAs soon as ELP is installed at a PV plant, it is mandatory that an SPD be installed, too. If the PV plant is not equipped with an ELP, the installation of an SPD is highly recommended to limit network perturbations (transient over voltages).\r\n\r\n<strong>SPD, g\u00fcne\u015f enerjisi santrallerinin DC taraf\u0131n\u0131 korumak i\u00e7in nas\u0131l \u00e7al\u0131\u015f\u0131r?<\/strong>\r\n\r\nA\u015f\u0131r\u0131 gerilimleri s\u0131n\u0131rlamak amac\u0131yla enerjinin ilk \u00f6nce topra\u011fa akmas\u0131n\u0131 garanti etmek i\u00e7in en \u00f6nemli bile\u015fen Metal Oksit Varist\u00f6rd\u00fcr (MOV, \u2018Varist\u00f6r\u2019, VARI-etkin diren\u00e7 STOR anlam\u0131na gelir). Bu bile\u015fen \u00f6yle bir \u00f6zelli\u011fe sahiptir ki, normal ko\u015fullarda (a\u015f\u0131r\u0131 gerilim yokken) diren\u00e7, i\u00e7inden nominal ak\u0131mlar\u0131n ge\u00e7mesini \u00f6nleyecek kadar y\u00fcksektir. Belirli bir a\u015f\u0131r\u0131 gerilim seviyesinden ba\u015flayarak diren\u00e7 h\u0131zla d\u00fc\u015fecek, topra\u011fa giden yol a\u00e7\u0131lacak ve bir kez normal duruma geri d\u00f6necektir.enerji da\u011f\u0131ld\u0131. Bu i\u015flem, a\u015fa\u011f\u0131 y\u00f6nde ba\u011fl\u0131 t\u00fcm ekipmanlara ula\u015fan a\u015f\u0131r\u0131 gerilim seviyesinin s\u0131n\u0131rland\u0131r\u0131lmas\u0131na olanak tan\u0131r.\r\n\r\n<img class=\"alignnone size-full wp-image-752\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-2.jpg\" alt=\"\" width=\"300\" height=\"300\" \/>\r\n\r\n<strong>Tip 1+2 SPD ve standart Tip 2 SPD, hangisi do\u011fru?<\/strong>\r\n\r\nThere are different types of SPDs available which vary in terms of resistance: Type 1, Type 2, and Type 1+2. A Type 1 SPD can cope with a direct strike which bring an energetic surge, whereas a Type 2 limits over voltages from various sources. Both characteristics can be combined into a \u201cType 1+2\u201d for complete protection.\r\n\r\nIn PV plants the challenge is to choose the appropriate surge protection to withstand pure energy 10\/350\u00b5s waveform currents (almost 10 times more powerful than type 2 8\/20 \u00b5s waveform) while at the same time taking space into consideration. In an inverter or junction box space always is top priority. Britec\u2019s BRPV series provides both Type 1+2 and Type 2 DC surge protection can protect against over voltages due to lightning strikes or network surge current.\r\n\r\n<img class=\"alignnone wp-image-754\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-4.jpg\" alt=\"\" width=\"292\" height=\"292\" \/><img class=\"alignnone wp-image-753\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-3.jpg\" alt=\"\" width=\"293\" height=\"293\" \/><img class=\"alignnone size-full wp-image-755\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-5.jpg\" alt=\"\" width=\"300\" height=\"300\" \/>","protected":false},"featured_media":779,"parent":0,"menu_order":184,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-750","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"At PV plants, SPDs have to fulfill specific requirements to ensure continuous operation and energy generation.","txt":"<strong>At PV plants, SPDs have to fulfill specific requirements to ensure continuous operation and energy generation.<\/strong>\r\n\r\nWhen designing a PV plant, it is important to consider the installation of surge protection devices (SPDs). Surges and network disturbances can lead to downtime, reducing the performance of the plant. Therefore, any conditions affecting energy generation and distribution should be taken into consideration when designing the electrical installation.\r\n\r\n<strong>Why are SPDs a top priority in PV plants?<\/strong>\r\n\r\nSolar panels are installed outside to convert solar energy into electricity. This outdoor location makes them directly exposed to harsh conditions like rain, wind and dust. Among the weather conditions lightning strikes require specific attention as they can severely affect the safety and performance of a PV plant. They originate in a cumulonimbus cloud and terminate on the ground. When the lightning strike hits the ground, it discharges energy, affecting the electrical field on the ground. For the solar PV plant this poses two risks:\r\n\r\nA direct impact which can physically destroy the solar equipment on a rooftop\r\n\r\nTransitory over voltages passing through cables by magnetic coupling, which can lead to the damage of sensitive components such as printed circuit boards (PCB).\r\n\r\nAs far as the direct impact is concerned, \u2018External Lightning Protects\u2019 (ELP) provide the required protection according to IEC 62305, which describes how to evaluate if your location needs such protection, and what should be the preferred option (meshed cages, air terminal, etc.). The concept is simple: make sure the lightning will strike a metallic rod installed on the highest point of your plant and dispel the energy directly to the ground through a copper down conductor.\r\n\r\nWhen it comes to transitory over voltages, however, SPDs are required. They are installed in parallel into the circuit protection boards to divert the energy to the ground and limit the overvoltage up to such value acceptable to the end equipment.\r\n\r\nAs soon as ELP is installed at a PV plant, it is mandatory that an SPD be installed, too. If the PV plant is not equipped with an ELP, the installation of an SPD is highly recommended to limit network perturbations (transient over voltages).\r\n\r\n<strong>How does an SPD work to protect the DC side of solar plants?<\/strong>\r\n\r\nTo guarantee the energy will flow to the ground first to limit over voltages the most important component is the Metal Oxide Varistor (MOV, \u2018Varistor\u2019 stands for VARI-able resi-STOR). This component has such propriety that in normal conditions (no over voltages) the resistance is high enough to not make possible nominal currents passing through it. Starting at a certain overvoltage level, the resistance will quickly drop, opening the path to the ground and coming back to a normal condition once the energy has been dissipated. This process allows limitation of the overvoltage level reaching all equipment connected downstream.\r\n\r\n<img class=\"alignnone size-full wp-image-752\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-2.jpg\" alt=\"\" width=\"300\" height=\"300\" \/>\r\n\r\n<strong>Type1+2 SPD versus standard Type 2 SPD, which one is the right one?<\/strong>\r\n\r\nThere are different types of SPDs available which vary in terms of resistance: Type 1, Type 2, and Type 1+2. A Type 1 SPD can cope with a direct strike which bring an energetic surge, whereas a Type 2 limits over voltages from various sources. Both characteristics can be combined into a \u201cType 1+2\u201d for complete protection.\r\n\r\nIn PV plants the challenge is to choose the appropriate surge protection to withstand pure energy 10\/350\u00b5s waveform currents (almost 10 times more powerful than type 2 8\/20 \u00b5s waveform) while at the same time taking space into consideration. In an inverter or junction box space always is top priority. Britec\u2019s BRPV series provides both Type 1+2 and Type 2 DC surge protection can protect against over voltages due to lightning strikes or network surge current.\r\n\r\n<img class=\"alignnone wp-image-754\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-4.jpg\" alt=\"\" width=\"292\" height=\"292\" \/><img class=\"alignnone wp-image-753\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-3.jpg\" alt=\"\" width=\"293\" height=\"293\" \/><img class=\"alignnone size-full wp-image-755\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-5.jpg\" alt=\"\" width=\"300\" height=\"300\" \/>"},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/blog\/750","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/media\/779"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/media?parent=750"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/blog_category?post=750"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}