{"id":908,"date":"2024-09-03T17:10:16","date_gmt":"2024-09-03T09:10:16","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=application&#038;p=908"},"modified":"2024-09-03T17:10:16","modified_gmt":"2024-09-03T09:10:16","slug":"surge-protection-for-photovoltaic-systems","status":"publish","type":"application","link":"https:\/\/www.britecelectric.com\/tr\/solution\/surge-protection-for-photovoltaic-systems\/","title":{"rendered":"Fotovoltaik Sistemler \u0130\u00e7in A\u015f\u0131r\u0131 Gerilim Korumas\u0131"},"content":{"rendered":"<p>Dolayl\u0131 y\u0131ld\u0131r\u0131m \u00e7arpmalar\u0131 y\u0131k\u0131c\u0131d\u0131r. Y\u0131ld\u0131r\u0131m aktivitesine ili\u015fkin anekdotsal g\u00f6zlemler genellikle PV dizilerinde y\u0131ld\u0131r\u0131m\u0131n neden oldu\u011fu a\u015f\u0131r\u0131 gerilim seviyesinin zay\u0131f bir g\u00f6stergesidir. Dolayl\u0131 y\u0131ld\u0131r\u0131m \u00e7arpmalar\u0131, PV ekipman\u0131 i\u00e7indeki hassas bile\u015fenlere kolayca zarar verebilir; bu da genellikle hasarl\u0131 bile\u015fenlerin onar\u0131lmas\u0131 veya de\u011fi\u015ftirilmesi i\u00e7in y\u00fcksek maliyetlidir ve PV sisteminin g\u00fcvenilirli\u011fini etkiler. A\u015f\u0131r\u0131 gerilim, her bir PV sisteminin kurulum ko\u015fullar\u0131na ve kablo ba\u011flant\u0131lar\u0131na ba\u011fl\u0131d\u0131r.<\/p>\n<p>PV sistemleri geni\u015f a\u00e7\u0131k alanlarda, genellikle tarlalarda veya binalar\u0131n tepelerinde kullan\u0131l\u0131r. Bu t\u00fcr a\u00e7\u0131k alanlar \u00fczerinde biriken y\u00fckl\u00fc ya\u011fmur bulutlar\u0131, y\u00fck\u00fc y\u0131ld\u0131r\u0131m \u015feklinde salma e\u011filimindedir. Bu oldu\u011funda, voltaj dalgalanmas\u0131 meydana gelmesi muhtemeldir. Alan ne kadar geni\u015f olursa, y\u0131k\u0131m\u0131n meydana gelme olas\u0131l\u0131\u011f\u0131 da o kadar artar.<\/p>\n<p>Bir PV sistemi end\u00fcstriyel bir siteye yerle\u015ftirildi\u011finde i\u015f operasyonlar\u0131 ve ekipmanlar\u0131 da tehlikeye girer. \u0130nverterler pahal\u0131d\u0131r, ancak end\u00fcstriyel uygulamalarda daha da pahal\u0131 bir ar\u0131za, ar\u0131za s\u00fcresinin maliyetidir.<\/p>\n<p>Bir g\u00fcne\u015f PV sistemine y\u0131ld\u0131r\u0131m d\u00fc\u015ft\u00fc\u011f\u00fcnde, g\u00fcne\u015f PV sisteminin kablo d\u00f6ng\u00fclerinde ind\u00fcklenen ge\u00e7ici bir ak\u0131ma ve gerilime neden olur. Bu ge\u00e7ici ak\u0131mlar ve voltajlar ekipman terminallerinde ortaya \u00e7\u0131kacak ve muhtemelen PV paneller, invert\u00f6r, kontrol ve ileti\u015fim ekipmanlar\u0131n\u0131n yan\u0131 s\u0131ra bina kurulumundaki cihazlar gibi solar PV elektrik ve elektronik bile\u015fenlerinde izolasyon ve dielektrik ar\u0131zalar\u0131na neden olacakt\u0131r. Dizi kutusu, invert\u00f6r ve MPPT (maksimum g\u00fc\u00e7nokta izleyici) cihaz\u0131 en y\u00fcksek ar\u0131za noktalar\u0131na sahiptir.<\/p>\n<p>Y\u00fcksek enerjinin elektroniklerden ge\u00e7mesini ve PV sisteminde y\u00fcksek voltaj hasar\u0131na neden olmas\u0131n\u0131 \u00f6nlemek i\u00e7in voltaj dalgalanmalar\u0131n\u0131n topra\u011fa giden bir yolu olmal\u0131d\u0131r. Bunu yapmak i\u00e7in t\u00fcm iletken y\u00fczeyler do\u011frudan topraklanmal\u0131 ve sisteme giren ve \u00e7\u0131kan t\u00fcm kablolar (Ethernet kablolar\u0131 ve AC \u015febekesi gibi) bir SPD arac\u0131l\u0131\u011f\u0131yla topra\u011fa ba\u011flanmal\u0131d\u0131r.<\/p>\n<p>Dizi kutusu, rekombinasyon kutusu ve ayr\u0131ca DC ba\u011flant\u0131 kesme i\u00e7indeki her dizi grubu i\u00e7in bir a\u015f\u0131r\u0131 gerilim koruma cihaz\u0131na ihtiya\u00e7 vard\u0131r.<\/p>\n<p><strong>PV Sistemleri i\u00e7in A\u015f\u0131r\u0131 Gerilim Koruma Cihaz\u0131 Se\u00e7imi ve Kurulumu<\/strong><\/p>\n<p>PV sistemleri benzersiz \u00f6zelliklere sahiptir ve bu nedenle PV sistemleri i\u00e7in \u00f6zel olarak tasarlanm\u0131\u015f SPD'lerin kullan\u0131m\u0131n\u0131 gerektirir.<\/p>\n<p>PV sistemler 1500 volta kadar y\u00fcksek DC sistem gerilimlerine sahiptir. Maksimum g\u00fc\u00e7 noktalar\u0131, sistemin k\u0131sa devre ak\u0131m\u0131n\u0131n yaln\u0131zca birka\u00e7 y\u00fczdelik alt\u0131nda \u00e7al\u0131\u015f\u0131r.<\/p>\n<p>PV sistemi ve kurulumu i\u00e7in uygun SPD mod\u00fcl\u00fcn\u00fc belirlemek i\u00e7in \u015funlar\u0131 bilmelisiniz:<\/p>\n<p>l \u015eim\u015fek yuvarlak fla\u015f yo\u011funlu\u011fu;<\/p>\n<p>l Sistemin \u00e7al\u0131\u015fma s\u0131cakl\u0131\u011f\u0131;<\/p>\n<p>l Sistemin voltaj\u0131;<\/p>\n<p>l Sistemin k\u0131sa devre ak\u0131m de\u011feri;<\/p>\n<p>l Kar\u015f\u0131 korunacak dalga formunun seviyesi (dolayl\u0131 veya do\u011frudan y\u0131ld\u0131r\u0131m);<\/p>\n<p>l Nominal de\u015farj ak\u0131m\u0131.<\/p>\n<p>Harici bir y\u0131ld\u0131r\u0131mdan korunma sistemi (LPS) taraf\u0131ndan korunan bir kurulum i\u00e7in SPD gereklilikleri, se\u00e7ilen LPS s\u0131n\u0131f\u0131na ve LPS ile PV kurulumu aras\u0131ndaki ay\u0131rma mesafesinin izole edilip edilmedi\u011fine ba\u011fl\u0131d\u0131r. IEC 62305-3, harici bir LPS i\u00e7in ay\u0131rma mesafesi gereksinimlerinin ayr\u0131nt\u0131lar\u0131n\u0131 verir.<\/p>\n<p>Koruyucu bir etkiye sahip olmak i\u00e7in, bir SPD'nin voltaj koruma seviyesi (Yukar\u0131), sistemin terminal ekipman\u0131n\u0131n dielektrik dayan\u0131m\u0131ndan 20 % daha d\u00fc\u015f\u00fck olmal\u0131d\u0131r.<\/p>\n<p>K\u0131sa devre dayan\u0131m ak\u0131m\u0131, SPD'nin ba\u011fl\u0131 oldu\u011fu g\u00fcne\u015f paneli dizisinin k\u0131sa devre ak\u0131m\u0131ndan daha b\u00fcy\u00fck olan bir SPD'nin kullan\u0131lmas\u0131 \u00f6nemlidir. DC \u00e7\u0131k\u0131\u015f\u0131nda sa\u011flanan SPD'nin, panelin maksimum fotovoltaik sistem voltaj\u0131na e\u015fit veya bundan daha b\u00fcy\u00fck bir DC MCOV'ye sahip olmas\u0131 gerekir.<\/p>\n<p><strong>Fotovoltaik Sistemlerin Dc Taraf\u0131 i\u00e7in SPD'ler<\/strong><\/p>\n<p>PV kaynaklar\u0131, geleneksel DC kaynaklardan \u00e7ok farkl\u0131 ak\u0131m ve gerilim \u00f6zelliklerine sahiptirler: do\u011frusal olmayan bir \u00f6zelli\u011fe sahiptirler ve ate\u015flenen arklar\u0131n uzun s\u00fcre kal\u0131c\u0131 olmas\u0131na neden olurlar. Bu nedenle, PV ak\u0131m kaynaklar\u0131 yaln\u0131zca daha b\u00fcy\u00fck PV anahtarlar\u0131 ve PV sigortalar\u0131 gerektirmez, ayn\u0131 zamanda bu benzersiz do\u011faya uyarlanm\u0131\u015f ve PV ak\u0131mlar\u0131yla ba\u015fa \u00e7\u0131kabilen a\u015f\u0131r\u0131 gerilim koruma cihaz\u0131 i\u00e7in bir ay\u0131r\u0131c\u0131ya da ihtiya\u00e7 duyar.<\/p>\n<p>DC taraf\u0131na tak\u0131lan SPD'ler her zaman \u00f6zel olarak DC uygulamalar\u0131 i\u00e7in tasarlanmal\u0131d\u0131r. Yanl\u0131\u015f ac veya dc taraf\u0131nda bir SPD'nin kullan\u0131lmas\u0131, ar\u0131za ko\u015fullar\u0131nda tehlikelidir.<\/p>\n<p><strong>Kurulum<\/strong><\/p>\n<p>SPD'ler her zaman koruyacaklar\u0131 cihazlar\u0131n yukar\u0131 ak\u0131\u015f\u0131na kurulmal\u0131d\u0131r. NFPA 780 12.4.2.1, g\u00fcne\u015f panelinin pozitiften topra\u011fa ve negatiften topra\u011fa do\u011fru DC \u00e7\u0131k\u0131\u015f\u0131nda, \u00e7oklu g\u00fcne\u015f panelleri i\u00e7in birle\u015ftirici ve rekombiner kutusunda ve invert\u00f6r\u00fcn ac \u00e7\u0131k\u0131\u015f\u0131nda a\u015f\u0131r\u0131 gerilim korumas\u0131n\u0131n sa\u011flanmas\u0131 gerekti\u011fini s\u00f6yl\u00fcyor.<\/p>\n<p>Bir SPD'nin do\u011fru kurulumu \u00fc\u00e7 de\u011fere dayan\u0131r:<\/p>\n<p>l Maksimum s\u00fcrekli \u00e7al\u0131\u015fma voltaj\u0131: SPD'nin etkinle\u015ftirece\u011fi voltaj.<\/p>\n<p>l Gerilim koruma seviyesi: Ekipman\u0131n a\u015f\u0131r\u0131 gerilim kategorisi, SPD'nin gerilim koruma seviyesinden y\u00fcksek olmal\u0131d\u0131r.<\/p>\n<p>l Nominal de\u015farj ak\u0131m\u0131: SPD'nin tekrarlayan dalgalanmalardan sonra dayanabilece\u011fi dalga formunun tepe de\u011feri (tip 2 SPD'ler i\u00e7in 8\/20 \u03bcs).<\/p>\n<p><strong>SPD'leri \u0130nvert\u00f6rlerle Birle\u015ftirme<\/strong><\/p>\n<p>PV \u00e7iftlikleri, kapsaml\u0131 korumaya ihtiya\u00e7 duyan \u00e7ok hassas ekipmanlardan olu\u015fur. PV \u00e7iftlikleri do\u011fru ak\u0131m (dc) g\u00fcc\u00fc \u00fcretti\u011finden, invert\u00f6rler (bu g\u00fcc\u00fc dc'den ac'ye d\u00f6n\u00fc\u015ft\u00fcrmek i\u00e7in gerekli olan) elektrik \u00fcretiminin \u00f6nemli bir bile\u015fenidir. Ne yaz\u0131k ki, invert\u00f6rler yaln\u0131zca y\u0131ld\u0131r\u0131m \u00e7arpmas\u0131na kar\u015f\u0131 olduk\u00e7a duyarl\u0131 olmakla kalm\u0131yor, ayn\u0131 zamanda inan\u0131lmaz derecede pahal\u0131lar.<\/p>\n<p>NFPA 780 12.4.2.3, sistem invert\u00f6r\u00fcn\u00fcn en yak\u0131n birle\u015ftirici veya rekombinat\u00f6r kutusundan 30 metreden daha uzakta olmas\u0131 durumunda invert\u00f6r\u00fcn dc giri\u015finde ek SPD'ler gerektirir.<\/p>\n<p>Dizi koruyucular (sigortalar, DC kesiciler veya dizi diyotlar\u0131 gibi) varsa, sigortalar ile invert\u00f6r aras\u0131na SPD'yi tak\u0131n.<\/p>\n<p>Entegre sigorta kutulu bir invert\u00f6r varken SPD'yi ba\u011flamak i\u00e7in dahili sigortalar\u0131n bypass edildi\u011finden ve harici dizi sigortalar\u0131n\u0131n ba\u011fl\u0131 oldu\u011fundan emin olun.<\/p>\n<p>Dizi invert\u00f6rleri dizilere m\u00fcmk\u00fcn oldu\u011funca yak\u0131n kurulmal\u0131d\u0131r. L+\/L- a\u011f\u0131na ve SPD'nin terminal blo\u011fu ile toprak baras\u0131 aras\u0131na ba\u011flanan SPD kablolar\u0131 2,5 metreden k\u0131sa olmal\u0131d\u0131r. Ba\u011flant\u0131 kablolar\u0131 ne kadar k\u0131sa olursa koruma o kadar verimli ve uygun maliyetli olacakt\u0131r.<\/p>\n<p>Yaln\u0131zca bir MPP izleyiciye sahip invert\u00f6rler i\u00e7in, invert\u00f6rden \u00f6nceki diziyi birle\u015ftirin ve bunlar\u0131 ara ba\u011flant\u0131 noktas\u0131nda SPD'ye ba\u011flay\u0131n.<\/p>\n<p>\u0130nverterde birden fazla MPP izleyici bulundu\u011funda her giri\u015f i\u00e7in SPD kombinasyonlar\u0131 planlanmal\u0131d\u0131r. Bir dizi diyotla birle\u015ftirilen her giri\u015f i\u00e7in bir SPD kullan\u0131lmal\u0131d\u0131r.<\/p>\n<p><strong>Referanslar<\/strong><\/p>\n<p>[1] Y\u0131ld\u0131r\u0131mdan Korunma K\u0131lavuzu, DIN EN Standard\u0131 62305 \u2013 3, 2014.<\/p>\n<p>[2] A\u015f\u0131r\u0131 Gerilim Koruma Cihazlar\u0131 Standard\u0131, UL 1449, 2014.<\/p>\n<p>[3] Al\u00e7ak gerilim a\u015f\u0131r\u0131 gerilim koruyucu cihazlar \u2013 B\u00f6l\u00fcm 32: DC'ye ba\u011fl\u0131 a\u015f\u0131r\u0131 gerilim koruyucu cihazlar. fotovoltaik tesislerin taraf\u0131 \u2013 Se\u00e7im ve uygulama ilkeleri, IEC Standard\u0131 61643-32, 2 017.<\/p>","protected":false},"featured_media":887,"template":"","class_list":["post-908","application","type-application","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/application\/908","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/application"}],"about":[{"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/types\/application"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/media\/887"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/media?parent=908"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}