{"id":889,"date":"2024-09-03T16:07:52","date_gmt":"2024-09-03T08:07:52","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=application&#038;p=889"},"modified":"2024-09-30T11:54:45","modified_gmt":"2024-09-30T03:54:45","slug":"data-center-surge-protection","status":"publish","type":"application","link":"https:\/\/www.britecelectric.com\/tr\/solution\/data-center-surge-protection\/","title":{"rendered":"Veri merkezi a\u015f\u0131r\u0131 gerilim korumas\u0131"},"content":{"rendered":"<p>Veri merkezlerini y\u0131ld\u0131r\u0131m \u00e7arpmas\u0131ndan korumak kolay bir i\u015f de\u011fildir.<\/p>\n<p><strong>G\u00fc\u00e7 besleme hatlar\u0131n\u0131n korunmas\u0131 ve enerji beslemesinin bak\u0131m\u0131:<\/strong><\/p>\n<p>Bir veri merkezinde g\u00fcc\u00fcn s\u00fcreklili\u011fi \u00e7ok \u00f6nemlidir. Veri merkezleri, yaln\u0131zca BT sistemlerini \u00e7al\u0131\u015ft\u0131rmak i\u00e7in de\u011fil ayn\u0131 zamanda ekipman\u0131 so\u011futmak i\u00e7in de b\u00fcy\u00fck miktarda enerji t\u00fcketir. Ancak bunlar\u0131n tamam\u0131 gerekti\u011fi gibi korunmuyor, bu da daha fazla korumaya olan ihtiyac\u0131n artt\u0131\u011f\u0131 anlam\u0131na geliyor.<\/p>\n<p>Y\u0131ld\u0131r\u0131m d\u00fc\u015fmesi sonucu olu\u015fan hasarlar\u0131n \u00e7o\u011fu, binaya giren hatlarda ind\u00fcklenen a\u015f\u0131r\u0131 gerilimler yoluyla elektrikli ve elektronik bile\u015fenleri etkilemektedir. Metalik borular (su, gaz vb.) de dalgalanmalara neden olabilir; \u00e7e\u015fitli hizmetler aras\u0131nda veya \u00e7e\u015fitli toprak ba\u011flant\u0131lar\u0131 aras\u0131nda e\u015fpotansiyel eksikli\u011fi, elektrik topra\u011f\u0131 ile s\u00f6zde \u201ctemiz\u201d bilgi i\u015flem topra\u011f\u0131 ayr\u0131ld\u0131\u011f\u0131nda sorunlara neden olabilir.<\/p>\n<p>Tip 1 + 2 parafudrlar\u0131n montaj\u0131, d\u00fc\u015f\u00fck art\u0131k a\u015f\u0131r\u0131 gerilim nedeniyle gelen enerji hatlar\u0131n\u0131 ve hassas devreleri y\u0131ld\u0131r\u0131m \u00e7arpmas\u0131 durumunda koruyabilir, ancak e\u015fpotansiyel bir sistem olu\u015fturmak i\u00e7in binaya giren metal borular\u0131n topraklanmas\u0131 gerekli olacakt\u0131r.<\/p>\n<p>Tip 2 parafudrlar ayn\u0131 zamanda bilgisayar sistemlerinin, invert\u00f6rlerin ve hassas ekipmanlar\u0131n korunmas\u0131 i\u00e7in de gereklidir. Bu parafudrlar sahada bulunan \u00e7e\u015fitli elektrik dolaplar\u0131na monte edilmelidir.<\/p>\n<p>Bir veri merkezinin dahili korumas\u0131, IEC 62305-4'te tan\u0131mland\u0131\u011f\u0131 gibi LPZ 0A'dan LPZ 3 b\u00f6lgesine kadar y\u0131ld\u0131r\u0131mdan korunma b\u00f6lgeleri konseptine uygun olarak ger\u00e7ekle\u015ftirilmelidir. Y\u0131ld\u0131r\u0131mdan korunma b\u00f6lgesi LPZ 0A, terminal ekipman\u0131n\u0131n bulundu\u011fu ve bu ekipman\u0131n g\u00fcvende kalmas\u0131 i\u00e7in art\u0131k a\u015f\u0131r\u0131 voltaj\u0131n d\u00fc\u015f\u00fck tutulmas\u0131 gereken b\u00f6lge olan LPZ 3 b\u00f6lgesine kadar do\u011frudan y\u0131ld\u0131r\u0131m d\u00fc\u015fmesinin m\u00fcmk\u00fcn oldu\u011fu b\u00f6lgedir. Enerjiyi \u00f6nlemek i\u00e7in \u00e7e\u015fitli parafudrlar tak\u0131lmal\u0131d\u0131r.elektrik \u015febekesinden ge\u00e7en y\u0131ld\u0131r\u0131m \u00e7arpmas\u0131ndan.<\/p>\n<p><strong>Veri merkezinde saklanan ve i\u015flenen verilerin korunmas\u0131:<\/strong><\/p>\n<p>Veri Merkezleri fiziksel ve siber sald\u0131r\u0131lara kar\u015f\u0131 savunmas\u0131zd\u0131r. H\u0131rs\u0131zl\u0131\u011fa kar\u015f\u0131 koruma sistemleri (kameralar, varl\u0131k dedekt\u00f6rleri...) ve ayn\u0131 zamanda y\u0131ld\u0131r\u0131m ve ak\u0131m dalgalanmalar\u0131na kar\u015f\u0131 da korunmas\u0131 gereken geli\u015fmi\u015f g\u00f6zetim sistemleriyle korunurlar. Bu sistemler \u00e7o\u011funlukla binalar\u0131n d\u0131\u015f\u0131nda bulunur ve veri merkezi sahalar\u0131 genellikle \u00e7ok geni\u015f oldu\u011fundan korunmalar\u0131 karma\u015f\u0131kt\u0131r.<\/p>\n<p>D\u0131\u015far\u0131dan i\u00e7eriye veri ileti\u015fimi esas olarak fiber optik kablo arac\u0131l\u0131\u011f\u0131yla yap\u0131lmaktad\u0131r. Bu ba\u011flant\u0131 t\u00fcr\u00fc a\u015f\u0131r\u0131 gerilime kar\u015f\u0131 ba\u011f\u0131\u015f\u0131kl\u0131d\u0131r ancak Telekom tipi \u00e7ok e\u015fli veri kablolar\u0131 arac\u0131l\u0131\u011f\u0131yla kablolu ba\u011flant\u0131lar mevcuttur. Bu tip iletken ba\u011flant\u0131lar \u00f6zellikle y\u0131ld\u0131r\u0131m\u0131n dolayl\u0131 etkilerine ve a\u015f\u0131r\u0131 gerilimlere kar\u015f\u0131 hassast\u0131r ve Tip 2 parafudrlarla korunmal\u0131d\u0131r. Koaksiyel kablo ba\u011flant\u0131lar\u0131 da frekans sinyal t\u00fcrlerine g\u00f6re korunmal\u0131d\u0131r,empedans, voltaj ve kullan\u0131lan konnekt\u00f6r t\u00fcrleri. \u0130zleme ekipmanlar\u0131, termal kameralar, kimlik kontrol sistemleri, g\u00fcvenlik kilitleri, yang\u0131n alg\u0131lama ve izinsiz giri\u015f tespit sistemleri de korunmal\u0131d\u0131r. Topraklama kitleri, d\u0131\u015f mekan antenleri ve d\u0131\u015f mekan g\u00f6zetleme kameralar\u0131 gibi t\u00fcm koaksiyel kablolardan kaynaklanan a\u015f\u0131r\u0131 voltaj\u0131 azaltmak i\u00e7in kullan\u0131labilir. Genellikle \u00e7ok damarl\u0131 kablolarla ba\u011flanan g\u00fcvenlik a\u00e7\u0131s\u0131ndan kritik ekipmanlar i\u00e7in Tip 2 parafudrlar kullan\u0131lmal\u0131d\u0131r. Koaksiyel, Ethernet, RS485 i\u00e7in veri koruma SPD'si,RS232, RJ11 vb. IEC61643-21'e uygun olmal\u0131d\u0131r.<\/p>\n<p><strong>Veri merkezi binalar\u0131n\u0131n korunmas\u0131:<\/strong><\/p>\n<p>\u0130leti\u015fim antenleri veya jenerat\u00f6r bacalar\u0131 gibi y\u00fcksek noktalara y\u0131ld\u0131r\u0131m \u00e7arpmas\u0131 ihtimali y\u00fcksektir. B\u00f6yle bir durumda y\u0131ld\u0131r\u0131m ak\u0131m\u0131, beton takviye demirleri, metal yap\u0131lar veya metal kaplama gibi herhangi bir iletken eleman \u00fczerinden topra\u011fa akacakt\u0131r. Y\u0131ld\u0131r\u0131mdan korunmak i\u00e7in bu y\u00fcksek noktalar\u0131n d\u0131\u015f iletkenlerle topra\u011fa ba\u011flanmas\u0131na \u00f6zellikle dikkat edilmelidir.<\/p>\n<p>Y\u0131ld\u0131r\u0131mdan korunma sisteminin \u015fok noktalar\u0131na sahip a\u011f kafes sistemi olarak veya erken ak\u0131\u015fl\u0131 hava terminali kullan\u0131larak kurulmas\u0131 tavsiye edilenden daha fazlas\u0131d\u0131r. Bu, binan\u0131n t\u00fcm y\u00fczeyini ve ayr\u0131ca di\u011fer hassas b\u00f6lgeleri veya merkezin d\u00fczg\u00fcn \u00e7al\u0131\u015fmas\u0131 i\u00e7in gerekli olan jenerat\u00f6rler, so\u011futma \u00fcniteleri veya yard\u0131mc\u0131 binalar gibi \u00e7evredeki binalar\u0131 kapsayan bir koruma yar\u0131\u00e7ap\u0131 sa\u011flamal\u0131d\u0131r.<\/p>\n<p>Y\u0131ld\u0131r\u0131m ak\u0131m\u0131n\u0131n y\u00fcksek noktalar (\u00f6rg\u00fc devresi, aktif veya pasif paratonerler) aras\u0131nda birden fazla ini\u015f iletkeni arac\u0131l\u0131\u011f\u0131yla b\u00f6l\u00fcnmesi ve topraklama sistemi iyidir. Bu, ak\u0131m\u0131 h\u0131zla topraklar ve gerekli ay\u0131rma mesafesini azalt\u0131r. Y\u0131ld\u0131r\u0131m ak\u0131m\u0131n\u0131n birden fazla iletken \u00fczerinden iyi bir \u015fekilde yay\u0131lmas\u0131, bina i\u00e7indeki iletkenlerin end\u00fcksiyon etkilerini azaltacakt\u0131r. Bu, binan\u0131n kablolamas\u0131 yoluyla ind\u00fcklenen a\u015f\u0131r\u0131 gerilimi azaltacak ve parafudrlar \u00fczerindeki etkiyi azaltacakt\u0131r.hayatlar\u0131n\u0131 uzatmak.<\/p>\n<p>\u00c7at\u0131da topra\u011fa ba\u011flanan ekipmanlar ile paratonerler aras\u0131ndaki mesafe \u00f6nemli bir husustur. 62305-1 standard\u0131 bu ay\u0131rma mesafesinin nas\u0131l hesaplanaca\u011f\u0131n\u0131 a\u00e7\u0131klamaktad\u0131r. Birbirine \u00e7ok yak\u0131n, ay\u0131rma mesafesinden az ise mutlaka yap\u0131\u015ft\u0131r\u0131lmal\u0131 ve bu \u00e7at\u0131 ekipman\u0131na g\u00fc\u00e7 sa\u011flayan t\u00fcm hatlara Tip 1 parafudr tak\u0131lmal\u0131d\u0131r. Ancak mesafenin b\u00fcy\u00fck olmas\u0131 durumunda herhangi bir birle\u015ftirme yap\u0131lmas\u0131na gerek kalmaz ve Tip 2 parafudrlar gerekir.yeterli. Tip 1 a\u015f\u0131r\u0131 gerilim koruma cihaz\u0131 (SPD), Tip 2 SPD'den 4-5 kat daha pahal\u0131d\u0131r.<\/p>","protected":false},"featured_media":824,"template":"","class_list":["post-889","application","type-application","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/application\/889","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/application"}],"about":[{"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/types\/application"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/media\/824"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/tr\/wp-json\/wp\/v2\/media?parent=889"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}