{"id":801,"date":"2023-12-19T16:44:04","date_gmt":"2023-12-19T08:44:04","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=801"},"modified":"2024-09-05T16:34:00","modified_gmt":"2024-09-05T08:34:00","slug":"the-difference-between-lightning-protection-and-surge-protection","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/sv\/blog\/the-difference-between-lightning-protection-and-surge-protection\/","title":{"rendered":"Skillnaden mellan \u00e5skskydd och \u00f6versp\u00e4nningsskydd"},"content":{"rendered":"Lightning and surge protection are two elements of an effective electrical protection system.\r\n\r\nLightning is known to be the most significant source of surges\u2014bolts have been recorded to have a million to a billion volts and between 10,000 to 200,000 amps. However, lightning only makes up a portion of all transient events in a facility.\r\n\r\nBecause transients can originate from both external sources (like lightning) and internal sources, facilities ought to have both a lightning protection system and surge protection installed.\r\n\r\n<strong>\u00c5skskyddssystem<\/strong>\r\n\r\nA lightning protection system protects a structure from a direct lightning strike.\r\n\r\nTo do this, an air terminal (or system of air terminals) is placed in the most probable position to capture the direct strike, based on the structure\u2019s architectural design and roof equipment. The rest of the system is designed to safely convey that electrical energy from the lighting strike to ground as efficiently and safely as possible.\r\n\r\nTo intercept the strike and conduct the high current energy of a lightning strike into the earth, system components include the:\r\n\r\nAir terminal, which is used to intercept the lightning strike.\r\n\r\nDown conductors, providing the most direct path possible to move the electrical energy towards the ground.\r\n\r\nGrounding system, which provides a path for the current to dissipate into the ground and out of harm\u2019s way.\r\n\r\nBonding, meant to reduce the possibility of voltage differences that are a safety risk.\r\n\r\nLightning protection standards ensure how to properly place air terminals, run cable, ground and bond in order to ensure maximum safety in this energy transfer and dissipation.\r\n\r\n<strong>\u00d6versp\u00e4nningsskyddsanordning (SPD)<\/strong>\r\n\r\nEn \u00f6versp\u00e4nningsskyddsanordning (SPD) \u00e4r utformad f\u00f6r att skydda elektriska system och utrustning fr\u00e5n \u00f6versp\u00e4nningar och transienta h\u00e4ndelser genom att begr\u00e4nsa transienta sp\u00e4nningar och avleda \u00f6versp\u00e4nningsstr\u00f6mmar.\r\n\r\n<strong>Vad orsakar transienter och \u00f6versp\u00e4nningar?<\/strong>\r\n\r\nLightning is the most spectacular form of an externally generated surge, however, it is estimated that 65% of all transients are generated internally within the facility by the switching of electrical loads such as:\r\n\r\nLightnings\r\n\r\nHeating systems\r\n\r\nMotors\r\n\r\nOther Inductive loads\r\n\r\n<strong>Hur fungerar en SPD?<\/strong>\r\n\r\nDet finns \u00e5tminstone en icke-linj\u00e4r komponent i SPD, som under olika f\u00f6rh\u00e5llanden \u00f6verg\u00e5r mellan ett h\u00f6g- och l\u00e5gimpedanstillst\u00e5nd. Vid normal driftsp\u00e4nning \u00e4r SPD:erna i ett h\u00f6gimpedanstillst\u00e5nd och p\u00e5verkar inte systemet. N\u00e4r en transientsp\u00e4nning uppst\u00e5r p\u00e5 kretsen, flyttar SPD:n till ett tillst\u00e5nd av ledning (eller l\u00e5g impedans) och avleder transientenergin och str\u00f6mmen tillbaka till sin k\u00e4lla eller jord. Detta begr\u00e4nsar eller kl\u00e4mmer sp\u00e4nningsamplituden till en s\u00e4krare niv\u00e5. Efter dentransienten avleds \u00e5terst\u00e4lls SPD automatiskt till sitt h\u00f6ga impedansl\u00e4ge.\r\n\r\n<strong>Vad skiljer de tv\u00e5 systemen \u00e5t?<\/strong>\r\n\r\nOn a basic level, the lightning protection system protects the facility and structure from direct strikes, while SPDs protect electrical equipment and systems against surges or transients.\r\n\r\nHow the two operate, and the components involved, also vary. Lightning protection system components are always in place and ready to function, while SPDs monitor internal system voltages and spring into action if a transient voltage occurs on the circuit.","protected":false},"featured_media":802,"parent":0,"menu_order":174,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-801","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"Lightning and surge protection are two elements of an effective electrical protection system.","txt":"Lightning and surge protection are two elements of an effective electrical protection system.\r\n\r\nLightning is known to be the most significant source of surges\u2014bolts have been recorded to have a million to a billion volts and between 10,000 to 200,000 amps. However, lightning only makes up a portion of all transient events in a facility.\r\n\r\nBecause transients can originate from both external sources (like lightning) and internal sources, facilities ought to have both a lightning protection system and surge protection installed.\r\n\r\n<strong>Lightning Protection System<\/strong>\r\n\r\nA lightning protection system protects a structure from a direct lightning strike.\r\n\r\nTo do this, an air terminal (or system of air terminals) is placed in the most probable position to capture the direct strike, based on the structure\u2019s architectural design and roof equipment. The rest of the system is designed to safely convey that electrical energy from the lighting strike to ground as efficiently and safely as possible.\r\n\r\nTo intercept the strike and conduct the high current energy of a lightning strike into the earth, system components include the:\r\n\r\nAir terminal, which is used to intercept the lightning strike.\r\n\r\nDown conductors, providing the most direct path possible to move the electrical energy towards the ground.\r\n\r\nGrounding system, which provides a path for the current to dissipate into the ground and out of harm\u2019s way.\r\n\r\nBonding, meant to reduce the possibility of voltage differences that are a safety risk.\r\n\r\nLightning protection standards ensure how to properly place air terminals, run cable, ground and bond in order to ensure maximum safety in this energy transfer and dissipation.\r\n\r\n<strong>Surge Protective Device (SPD)<\/strong>\r\n\r\nA surge protective device (SPD) is designed to protect electrical systems and equipment from surge and transient events by limiting transient voltages and diverting surge currents.\r\n\r\n<strong>What causes transients and surges?<\/strong>\r\n\r\nLightning is the most spectacular form of an externally generated surge, however, it is estimated that 65% of all transients are generated internally within the facility by the switching of electrical loads such as:\r\n\r\nLightnings\r\n\r\nHeating systems\r\n\r\nMotors\r\n\r\nOther Inductive loads\r\n\r\n<strong>How does a SPD work?<\/strong>\r\n\r\nThere is at least one non-linear component of the SPD, which under different conditions, transitions between a high and low impedance state. At normal operating voltages, the SPDs are in a high impedance state and do not affect the system. When a transient voltage occurs on the circuit, the SPD moves into a state of conduction (or low impedance) and diverts the transient energy and current back to its source or ground. This limits or clamps the voltage amplitude to a safer level. After the transient is diverted, the SPD automatically resets back to its high impedance state.\r\n\r\n<strong>What Sets the Two Systems Apart?<\/strong>\r\n\r\nOn a basic level, the lightning protection system protects the facility and structure from direct strikes, while SPDs protect electrical equipment and systems against surges or transients.\r\n\r\nHow the two operate, and the components involved, also vary. Lightning protection system components are always in place and ready to function, while SPDs monitor internal system voltages and spring into action if a transient voltage occurs on the circuit."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/blog\/801","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/media\/802"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/media?parent=801"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/blog_category?post=801"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}