{"id":799,"date":"2023-12-19T16:33:42","date_gmt":"2023-12-19T08:33:42","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=799"},"modified":"2024-09-05T16:36:48","modified_gmt":"2024-09-05T08:36:48","slug":"799-2","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/sv\/blog\/799-2\/","title":{"rendered":"\u00d6versp\u00e4nningsskydd: Vad b\u00f6r noteras?"},"content":{"rendered":"Effektivt \u00f6versp\u00e4nningsskydd \u00e4r inte bara installerat. Det m\u00e5ste vara individuellt koordinerat \u2013 till systemet som ska skyddas och de omgivningsf\u00f6rh\u00e5llanden som r\u00e5der p\u00e5 plats. Av denna anledning m\u00e5ste designen och konceptet vara konsekventa. Detta inneb\u00e4r att m\u00e5nga detaljer m\u00e5ste beaktas, fr\u00e5n att \u00f6verv\u00e4ga standarder och best\u00e4mmelser \u00e4nda fram till klassificering enligt \u00e5skskyddszon.\r\n\r\n<strong>\u00c5sk- och \u00f6versp\u00e4nningsskyddsstandarder<\/strong>\r\n\r\nNationella och internationella standarder ger v\u00e4gledning f\u00f6r att etablera ett blixt- och \u00f6versp\u00e4nningsskyddskoncept samt utformningen av de enskilda skyddsanordningarna.\r\n\r\n<strong>\u00c5skskydd enligt IEC 62305<\/strong><strong>:<\/strong>\r\n\r\nPart 1: Characteristics of lightning strikes\r\n\r\nIn Part 1 of this standard [1], the characteristic properties of lightning strikes, the likelihood of occurrence, and the potential for hazard are taken into account.\r\n\r\nPart 2: Risk analysis\r\n\r\nThe risk analysis according to Part 2 of this standard [2] describes a process with which, first of all, the need for lightning protection for a physical system is analyzed. Various sources of damage, e.g., a direct lightning strike in the building, come into focus, as do the types of damage resulting from this:\r\n\r\n\u2022 Impact on health or loss of life\r\n\r\n\u2022 Loss of technical services for the public\r\n\r\n\u2022 Loss of irreplaceable objects of cultural significance\r\n\r\n\u2022 Financial losses\r\n\r\nThe financial benefits are determined as follows: how does the annual total cost for a lightning protection system compare to the costs of potential damage without a protection system? The cost evaluation is based on the outgoings for the planning, assembly, and maintenance of the lightning protection system.\r\n\r\nParts 3 and 4: Planning aids and specifications\r\n\r\nIf the risk assessment determines that lightning protection is required and cost-effective, then the type and scope of the specific measures for protection can be planned based on Parts 3 [3] and 4 [4] of this standard. The lightning protection level determined by risk management is decisive for determining the type and scope of the measures.\r\n\r\nFor physical structures that require an extremely high level of safety, almost all strikes must be captured and conducted away safely. For systems where a higher residual risk is acceptable, strikes with lower amplitudes are not captured.\r\n\r\n<strong>\u00d6versp\u00e4nningsskydd enligt IEC 60364-4-44<\/strong>\r\n\r\nThis standard [5] describes the conditions in which surge protective devices are to be used in low-voltage systems to protect the electrical installation against surge voltages. The area of application is thereby limited to surge voltages caused by atmospheric influences or as a consequence of switching procedures that are transmitted by the power supply system. Direct lightning strikes in a structural system are not considered, only strikes in or in the vicinity of supply lines.\r\n\r\nLikewise, structural systems with an explosion risk as well as structural applications that could cause damage to the environment (e.g., petrochemical systems or nuclear power plants) are not included in the application of the standard. For these processes, lightning strike standard IEC 62305 is to be used exclusively.\r\n\r\nSurge protective devices should be used if transient overvoltage could have effects on the following:\r\n\r\n\u2022 Human lives, e.g., safety systems, hospitals\r\n\r\n\u2022 Public and cultural institutions, e.g., loss of public services, IT centers, museums\r\n\r\n\u2022 Industrial or business activities, e.g., hotels, banks, production systems, farms.\r\n\r\n<strong>Grundl\u00e4ggande skydds\u00e5tg\u00e4rder och utrustning<\/strong>\r\n\r\nIn order to consistently protect a structural system from lightning strikes and surge voltages, various protective measures or equipment that are tailored to one another are required. A broad division can be made as follows:\r\n\r\n\u2022 External lightning protection\r\n\r\n\u2022 Internal lightning protection\r\n\r\n\u2022 Grounding and equipotential bonding\r\n\r\n\u2022 Coordinated SPD system\r\n\r\n<strong>Externt \u00e5skskydd<\/strong>\r\n\r\nExternt \u00e5skskydd (fig. 15) syftar till att avleda nedslag som kommer n\u00e4ra objektet som ska skyddas och att \u00f6verf\u00f6ra blixtstr\u00f6mmen fr\u00e5n den punkt d\u00e4r den tr\u00e4ffar till marken. Som s\u00e5dan kan ingen skada orsakas av termiska, magnetiska eller elektriska effekter. Externt \u00e5skskydd \u00e4r systematiskt: det best\u00e5r av luftterminalen, avledaren och jordningssystemet.\r\n\r\n<strong><img class=\"aligncenter\" title=\"10\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/07\/2022082915121199ec989ea1544a65b3dcd6f5dc7aceb0.webp\" alt=\"10\" width=\"300\" height=\"338\" border=\"0\" vspace=\"0\" \/><\/strong>\r\n\r\n<strong>Internt \u00e5skskydd<\/strong>\r\n\r\nThe internal lightning protection system should prevent dangerous spark formation inside the system. Sparks can be caused by lightning current in the external lightning protection system or in other conductive parts of the structural system.\r\n\r\nThe internal lightning protection system consists of equipotential bonding and the electrical insulation of external lightning protection systems.\r\n\r\nLightning protection equipotential bonding is a combination of measures that prevent potential differences. They mainly connect the lightning protection system to metal installations, internal systems, as well as electrical and electronic systems within the system.\u00a0This occurs by means of equipotential bonding lines, surge protective devices or isolating spark gaps.\r\n\r\n<strong>Jordning och potentialutj\u00e4mning<\/strong>\r\n\r\nJordningssystemet syftar till att distribuera och ladda ur den f\u00e5ngade blixtstr\u00f6mmen till jord. H\u00e4r \u00e4r typen av jordsystem viktigare \u00e4n jordningsmotst\u00e5ndet. Blixtstr\u00f6mmen \u00e4r en mycket kort puls som beter sig som en h\u00f6gfrekvent str\u00f6m. Effektiv potentialutj\u00e4mning \u00e4r ocks\u00e5 viktig. Potentialutj\u00e4mning f\u00f6rbinder alla elektriskt ledande delar med varandra via ledare \u2013 aktiva ledare skyddas av \u00f6versp\u00e4nningsskydd. Genom att g\u00f6ra s\u00e5, detskyddar mot alla typer av kopplingar.\r\n\r\n<strong>Samordnat SPD-system<\/strong>\r\n\r\nA coordinated SPD system is understood to be a multi-level system of surge protective devices that are coordinated with each other.\r\n\r\nThe following steps are recommended in order to achieve a high-performance SPD system.\r\n\r\n\u2022\u00a0Divide the structural system into lightning protection zones\r\n\r\n\u2022 Incorporate all lines that cross between different zones into the local equipotential bonding using suitable SPDs\r\n\r\n\u2022 Coordinate different types of SPDs: the devices must address each other selectively in order to prevent individual components from overloading\r\n\r\n\u2022 Use short supply lines for the parallel connection of SPDs between active conductors and the equipotential bonding\r\n\r\n\u2022 Lay protected and unprotected lines separately\r\n\r\n\u2022 Only ground equipment via the respective SPD (recommended)\r\n\r\n<strong>\u00c5skskyddszoner<\/strong>\r\n\r\nDeciding where to install surge protective devices within a structural system is based on the lightning protection zone concept explained in Part 4 of the lightning protection standard IEC 62305 [4].\r\n\r\nIt divides structural systems into lightning protection zones (LPZ), and does so from outside to inside with decreasing lightning protection levels. In external zones only resistant equipment can be used. However, in internal zones, sensitive equipment can also be used. The individual zones are characterized and named as follows:\r\n\r\n<strong>LPZ 0A<\/strong>\r\n\r\nOskyddat omr\u00e5de utanf\u00f6r en byggnad d\u00e4r direkt blixtnedslag\u00a0\u00e4r\u00a0en m\u00f6jlighet. Direkt koppling av blixtstr\u00f6mmar i linjer, od\u00e4mpat magnetf\u00e4lt av blixtnedslaget\r\n\r\n<strong>LPZ 0B<\/strong>\r\n\r\nOmr\u00e5de utanf\u00f6r byggnaden som \u00e4r skyddat fr\u00e5n direkta blixtnedslag med hj\u00e4lp av en luftterminal. Od\u00e4mpat magnetf\u00e4lt fr\u00e5n blixtnedslaget inducerade endast \u00f6versp\u00e4nningsstr\u00f6mmar p\u00e5 linjer.\r\n\r\n<strong>LPZ 1<\/strong>\r\n\r\nOmr\u00e5de inuti byggnaden som fortfarande kan uts\u00e4ttas f\u00f6r h\u00f6genergi\u00f6versp\u00e4nningar eller \u00f6versp\u00e4nningsstr\u00f6mmar och starka elektromagnetiska f\u00e4lt\r\n\r\n<strong>LPZ 2<\/strong>\r\n\r\nOmr\u00e5de inuti en byggnad som fortfarande kan uts\u00e4ttas f\u00f6r \u00f6versp\u00e4nningar eller \u00f6versp\u00e4nningsstr\u00f6mmar och elektromagnetiska f\u00e4lt som redan har f\u00f6rsvagats avsev\u00e4rt.\r\n\r\n<strong>LPZ 3<\/strong>\r\n\r\nArea inside the building which may only be subjected to extremely low or hardly any surge voltages or surge currents and very weak or non-existent electromagnetic fields.\r\n\r\nAll lines that cross between zones must use coordinated surge protective devices. Their power values are based on the protection class to be achieved, which is determined according to legal specifications or by means of the risk analysis. When it comes to selecting surge protective devices, use the standard as a basis, assuming that 50% of the lightning current will be discharged to ground. The other 50% of the lightning current is directed to the electrical installation via the main equipotential bonding and from there must be conducted away from the SPD system.","protected":false},"featured_media":800,"parent":0,"menu_order":175,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-799","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"Effective surge protection is not just simply installed. It has to be individually coordinated \u2013 to the system that is to be protected and the ambient conditions that are prevalent on site.","txt":"Effective surge protection is not just simply installed. It has to be individually coordinated \u2013 to the system that is to be protected and the ambient conditions that are prevalent on site. For this reason, the design and concept must be consistent. This means many details must be taken into account, from considering the standards and stipulations right through to classification according to lightning protection zone.\r\n\r\n<strong>Lightning and surge protection standards<\/strong>\r\n\r\nNational and international standards provide a guide to establishing a lightning and surge protection concept as well as the design of the individual protective devices.\r\n\r\n<strong>Lightning protection according to IEC 62305<\/strong><strong>:<\/strong>\r\n\r\nPart 1: Characteristics of lightning strikes\r\n\r\nIn Part 1 of this standard [1], the characteristic properties of lightning strikes, the likelihood of occurrence, and the potential for hazard are taken into account.\r\n\r\nPart 2: Risk analysis\r\n\r\nThe risk analysis according to Part 2 of this standard [2] describes a process with which, first of all, the need for lightning protection for a physical system is analyzed. Various sources of damage, e.g., a direct lightning strike in the building, come into focus, as do the types of damage resulting from this:\r\n\r\n\u2022 Impact on health or loss of life\r\n\r\n\u2022 Loss of technical services for the public\r\n\r\n\u2022 Loss of irreplaceable objects of cultural significance\r\n\r\n\u2022 Financial losses\r\n\r\nThe financial benefits are determined as follows: how does the annual total cost for a lightning protection system compare to the costs of potential damage without a protection system? The cost evaluation is based on the outgoings for the planning, assembly, and maintenance of the lightning protection system.\r\n\r\nParts 3 and 4: Planning aids and specifications\r\n\r\nIf the risk assessment determines that lightning protection is required and cost-effective, then the type and scope of the specific measures for protection can be planned based on Parts 3 [3] and 4 [4] of this standard. The lightning protection level determined by risk management is decisive for determining the type and scope of the measures.\r\n\r\nFor physical structures that require an extremely high level of safety, almost all strikes must be captured and conducted away safely. For systems where a higher residual risk is acceptable, strikes with lower amplitudes are not captured.\r\n\r\n<strong>Surge protection according to IEC 60364-4-44<\/strong>\r\n\r\nThis standard [5] describes the conditions in which surge protective devices are to be used in low-voltage systems to protect the electrical installation against surge voltages. The area of application is thereby limited to surge voltages caused by atmospheric influences or as a consequence of switching procedures that are transmitted by the power supply system. Direct lightning strikes in a structural system are not considered, only strikes in or in the vicinity of supply lines.\r\n\r\nLikewise, structural systems with an explosion risk as well as structural applications that could cause damage to the environment (e.g., petrochemical systems or nuclear power plants) are not included in the application of the standard. For these processes, lightning strike standard IEC 62305 is to be used exclusively.\r\n\r\nSurge protective devices should be used if transient overvoltage could have effects on the following:\r\n\r\n\u2022 Human lives, e.g., safety systems, hospitals\r\n\r\n\u2022 Public and cultural institutions, e.g., loss of public services, IT centers, museums\r\n\r\n\u2022 Industrial or business activities, e.g., hotels, banks, production systems, farms.\r\n\r\n<strong>Basic protective measures and equipment<\/strong>\r\n\r\nIn order to consistently protect a structural system from lightning strikes and surge voltages, various protective measures or equipment that are tailored to one another are required. A broad division can be made as follows:\r\n\r\n\u2022 External lightning protection\r\n\r\n\u2022 Internal lightning protection\r\n\r\n\u2022 Grounding and equipotential bonding\r\n\r\n\u2022 Coordinated SPD system\r\n\r\n<strong>External lightning protection<\/strong>\r\n\r\nExternal lightning protection (Fig. 15) aims to divert strikes which come near to the object to be protected and to transmit the lightning current from the point where it hits to ground. As such, no damage can be caused by means of thermal, magnetic or electrical effects. External lightning protection is systematic: it consists of the air-terminal, the arresters, and the grounding system.\r\n\r\n<strong><img class=\"aligncenter\" title=\"10\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/07\/2022082915121199ec989ea1544a65b3dcd6f5dc7aceb0.webp\" alt=\"10\" width=\"300\" height=\"338\" border=\"0\" vspace=\"0\" \/><\/strong>\r\n\r\n<strong>Internal lightning protection<\/strong>\r\n\r\nThe internal lightning protection system should prevent dangerous spark formation inside the system. Sparks can be caused by lightning current in the external lightning protection system or in other conductive parts of the structural system.\r\n\r\nThe internal lightning protection system consists of equipotential bonding and the electrical insulation of external lightning protection systems.\r\n\r\nLightning protection equipotential bonding is a combination of measures that prevent potential differences. They mainly connect the lightning protection system to metal installations, internal systems, as well as electrical and electronic systems within the system.\u00a0This occurs by means of equipotential bonding lines, surge protective devices or isolating spark gaps.\r\n\r\n<strong>Grounding and equipotential bonding<\/strong>\r\n\r\nThe grounding system aims to distribute and discharge the captured lightning current to ground. Here, the type of grounding system is more important than the grounding resistance. The lightning current is a very short pulse that behaves like a high-frequency current. Effective equipotential bonding is also important. Equipotential bonding connects all electrically conductive parts with each other via conductors \u2013 active conductors are protected by surge protective devices. By doing so, it protects against all types of couplings.\r\n\r\n<strong>Coordinated SPD system<\/strong>\r\n\r\nA coordinated SPD system is understood to be a multi-level system of surge protective devices that are coordinated with each other.\r\n\r\nThe following steps are recommended in order to achieve a high-performance SPD system.\r\n\r\n\u2022\u00a0Divide the structural system into lightning protection zones\r\n\r\n\u2022 Incorporate all lines that cross between different zones into the local equipotential bonding using suitable SPDs\r\n\r\n\u2022 Coordinate different types of SPDs: the devices must address each other selectively in order to prevent individual components from overloading\r\n\r\n\u2022 Use short supply lines for the parallel connection of SPDs between active conductors and the equipotential bonding\r\n\r\n\u2022 Lay protected and unprotected lines separately\r\n\r\n\u2022 Only ground equipment via the respective SPD (recommended)\r\n\r\n<strong>Lightning protection zones<\/strong>\r\n\r\nDeciding where to install surge protective devices within a structural system is based on the lightning protection zone concept explained in Part 4 of the lightning protection standard IEC 62305 [4].\r\n\r\nIt divides structural systems into lightning protection zones (LPZ), and does so from outside to inside with decreasing lightning protection levels. In external zones only resistant equipment can be used. However, in internal zones, sensitive equipment can also be used. The individual zones are characterized and named as follows:\r\n\r\n<strong>LPZ 0A<\/strong>\r\n\r\nUnprotected area outside a building in which direct lightning strikes\u00a0is\u00a0a possibility. Direct coupling of lightning currents in lines, unattenuated magnetic field of the lightning strike\r\n\r\n<strong>LPZ 0B<\/strong>\r\n\r\nArea outside the building that is protected from direct lightning strikes by means of an air-terminal. Unattenuated magnetic field of the lightning strike only induced surge currents on lines.\r\n\r\n<strong>LPZ 1<\/strong>\r\n\r\nArea inside the building which may still be subjected to high-energy surge voltages or surge currents and strong electromagnetic fields\r\n\r\n<strong>LPZ 2<\/strong>\r\n\r\nArea inside a building which may still be subjected to surge voltages or surge currents and electromagnetic fields that have already been significantly weakened.\r\n\r\n<strong>LPZ 3<\/strong>\r\n\r\nArea inside the building which may only be subjected to extremely low or hardly any surge voltages or surge currents and very weak or non-existent electromagnetic fields.\r\n\r\nAll lines that cross between zones must use coordinated surge protective devices. Their power values are based on the protection class to be achieved, which is determined according to legal specifications or by means of the risk analysis. When it comes to selecting surge protective devices, use the standard as a basis, assuming that 50% of the lightning current will be discharged to ground. The other 50% of the lightning current is directed to the electrical installation via the main equipotential bonding and from there must be conducted away from the SPD system."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/blog\/799","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/media\/800"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/media?parent=799"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/blog_category?post=799"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}