{"id":2214,"date":"2025-09-29T15:19:40","date_gmt":"2025-09-29T07:19:40","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=2214"},"modified":"2025-09-29T15:19:40","modified_gmt":"2025-09-29T07:19:40","slug":"how-to-install-type-12-lightning-surge-arresters","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/sv\/blog\/how-to-install-type-12-lightning-surge-arresters\/","title":{"rendered":"Hur installerar man \u00e5skskydd av typ 1+2?"},"content":{"rendered":"<h2><strong><b>1. Inledning<\/b><\/strong><\/h2>\r\nBlixtnedslag och v\u00e4xlingsst\u00f6tar utg\u00f6r en allvarlig risk f\u00f6r moderna elsystem. Utan ordentligt skydd kan de skada k\u00e4nslig utrustning, st\u00f6ra verksamheten och till och med orsaka brandrisker. Installera en <a href=\"https:\/\/www.britecelectric.com\/sv\/product-category\/ac-power-surge-protection\/type-1-2-lightning-surge-arrester\/\" target=\"_blank\" rel=\"noopener\"><strong>\u00c5sk\u00f6versp\u00e4nningsavledare av typ 1+2<\/strong><\/a>\u00a0\u00e4r ett mycket effektivt s\u00e4tt att tillhandah\u00e5lla <strong>\u00d6versp\u00e4nningsskydd f\u00f6r v\u00e4xelstr\u00f6m<\/strong>, vilket s\u00e4kerst\u00e4ller b\u00e5de s\u00e4kerhet och systemtillf\u00f6rlitlighet. Den h\u00e4r guiden f\u00f6rklarar vad typ 1+2 \u00f6versp\u00e4nningsavledare \u00e4r, hur man installerar dem korrekt och b\u00e4sta praxis f\u00f6r l\u00e5ngsiktig prestanda.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/sv\/product-category\/ac-power-surge-protection\/type-1-2-lightning-surge-arrester\/\" target=\"_blank\" rel=\"noopener\"><img class=\"alignnone size-full wp-image-2215\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2025\/09\/How-to-Install-Type-12-Lightning-Surge-Arresters.png\" alt=\"\" width=\"510\" height=\"510\" \/><\/a>\r\n<h2><strong><b>2. Vad \u00e4r en blixtavledare av typ 1+2?<\/b><\/strong><\/h2>\r\n<h3><strong><b>2-1 Definition och arbetsprincip<\/b><\/strong><\/h3>\r\nA<a href=\"https:\/\/www.britecelectric.com\/sv\/product-category\/ac-power-surge-protection\/type-1-2-lightning-surge-arrester\/\" target=\"_blank\" rel=\"noopener\"> <strong>\u00c5sk\u00f6versp\u00e4nningsavledare av typ 1+2<\/strong>\u00a0<\/a>\u00e4r en skyddsanordning utformad f\u00f6r att skydda elektriska system fr\u00e5n blixtst\u00f6tar med h\u00f6g energi (typ 1) och kopplingsst\u00f6tar p\u00e5 l\u00e4gre niv\u00e5 (typ 2). Den absorberar eller avleder \u00f6verfl\u00f6dig \u00f6versp\u00e4nningsenergi ner i marken och h\u00e5ller ansluten utrustning s\u00e4ker.\r\n<h3><strong><b>2-2 Skillnad mellan <a href=\"https:\/\/www.britecelectric.com\/sv\/product-category\/ac-power-surge-protection\/type-1-2-lightning-surge-arrester\/\" target=\"_blank\" rel=\"noopener\">Typ 1 och Typ 2 skydd<\/a><\/b><\/strong><\/h3>\r\n<strong>\u00d6versp\u00e4nningsskydd typ 1<\/strong>: Installerad vid huvudentr\u00e9n, designad f\u00f6r att hantera direkta blixtstr\u00f6mmar.\r\n\r\n<strong>\u00d6versp\u00e4nningsskydd typ 2<\/strong>: Installerad nedstr\u00f6ms, skyddar mot v\u00e4xlingsst\u00f6tar och kvarvarande blixtenergi.\r\n\r\n<strong>Typ 1+2 kombination<\/strong>: Ger b\u00e5da skyddsniv\u00e5erna i en enda enhet, vilket s\u00e4kerst\u00e4ller full t\u00e4ckning.\r\n<h2><strong><b>3. Planering f\u00f6r installation<\/b><\/strong><\/h2>\r\n<h3><strong><b>3-1 Utv\u00e4rdering av det elektriska systemet och \u00f6versp\u00e4nningsrisker<\/b><\/strong><\/h3>\r\nBed\u00f6m kraftdistributionssystemet, identifiera h\u00f6griskomr\u00e5den (t.ex. serviceing\u00e5ng, utomhusutrustning) och best\u00e4m erforderlig \u00f6versp\u00e4nningsstr\u00f6m.\r\n<h3><strong><b>3-2 V\u00e4lja r\u00e4tt sp\u00e4rrmodell<\/b><\/strong><\/h3>\r\nV\u00e4lj en avledare med l\u00e4mplig <strong>sp\u00e4nningsklass<\/strong>, <strong>\u00f6versp\u00e4nningsstr\u00f6mkapacitet<\/strong>, och \u00f6verensst\u00e4mmelse med IEC\/UL-standarder.\r\n<h3><strong><b>3-3 F\u00f6rbereda verktyg och s\u00e4kerhetsutrustning<\/b><\/strong><\/h3>\r\nF\u00f6re installation, samla isolerade verktyg, skyddshandskar och testutrustning. F\u00f6lj alltid elektriska s\u00e4kerhetsf\u00f6reskrifter.\r\n<h2><strong><b>4. Placering och placering av \u00f6versp\u00e4nningsavledare<\/b><\/strong><\/h2>\r\n<h3><strong><b>4-1 Rekommenderad installationsplats<\/b><\/strong><\/h3>\r\nDen b\u00e4sta platsen f\u00f6r en <strong>\u00c5sk\u00f6versp\u00e4nningsavledare av typ 1+2<\/strong>\u00a0\u00e4r vid <strong>huvuding\u00e5ng f\u00f6r service<\/strong>, d\u00e4r \u00f6versp\u00e4nningar f\u00f6rst kommer in i byggnaden.\r\n<h3><strong><b>4-2 Samordning med nedstr\u00f6ms SPD<\/b><\/strong><\/h3>\r\nF\u00f6r maximalt skydd, samordna med typ 3 SPD:er installerade n\u00e4ra k\u00e4nslig utrustning (datorer, servrar, medicinsk utrustning).\r\n<h3><strong><b>4-3 S\u00e4kerst\u00e4lla optimalt avst\u00e5nd fr\u00e5n k\u00e4nslig utrustning<\/b><\/strong><\/h3>\r\nKortare ledningar mellan avledaren och utrustningen minskar impedansen, vilket f\u00f6rb\u00e4ttrar skyddseffektiviteten.\r\n<h2><strong><b>5. Korrekt jordning f\u00f6r \u00f6versp\u00e4nningsavledare<\/b><\/strong><\/h2>\r\n<h3><strong><b>5-1 Vikten av ett l\u00e5gimpedansjordsystem<\/b><\/strong><\/h3>\r\nEffektivt \u00f6versp\u00e4nningsskydd beror p\u00e5 a <strong>solid och l\u00e5gresistans jordningsn\u00e4tverk<\/strong>. H\u00f6g impedans kan minska avledarens prestanda.\r\n<h3><strong><b>5-2 Metoder f\u00f6r att ansluta arresteraren<\/b><\/strong><\/h3>\r\nAnv\u00e4nd korta, tjocka ledare f\u00f6r att ansluta avledaren till jordskenan eller jordningselektroden. Undvik skarpa b\u00f6jar i kablar.\r\n<h3><strong><b>5-3 \u00d6verensst\u00e4mmelse med standarder<\/b><\/strong><\/h3>\r\nSe till att jordningsmetoderna st\u00e4mmer \u00f6verens <strong>lokala elf\u00f6reskrifter<\/strong>\u00a0(t.ex. IEC 62305, NEC).\r\n<h2><strong><b>6. Steg-f\u00f6r-steg installationsguide<\/b><\/strong><\/h2>\r\n<h3><strong><b>6-1 St\u00e4nga av str\u00f6mmen och s\u00e4kerhets\u00e5tg\u00e4rder<\/b><\/strong><\/h3>\r\nF\u00f6re installation, koppla bort str\u00f6mf\u00f6rs\u00f6rjningen och kontrollera att systemet \u00e4r str\u00f6ml\u00f6st.\r\n<h3><strong><b>6-2 Montering av <a href=\"https:\/\/www.britecelectric.com\/sv\/product-category\/ac-power-surge-protection\/type-1-2-lightning-surge-arrester\/\" target=\"_blank\" rel=\"noopener\">\u00d6versp\u00e4nningsavledare typ 1+2<\/a><\/b><\/strong><\/h3>\r\nF\u00e4st avledaren p\u00e5 en DIN-skena eller panelf\u00e4ste i f\u00f6rdelningspanelen.\r\n<h3><strong><b>6-3 Anslutnings-, neutral- och jordterminaler<\/b><\/strong><\/h3>\r\nAnsluta <strong>faslinjer<\/strong>\u00a0(L) to the arrester\u2019s line terminals.\r\n\r\nConnect <strong>neutral (N)<\/strong>\u00a0if required by the arrester design.\r\n\r\nConnect <strong>mark (PE)<\/strong>\u00a0direkt till jordningsn\u00e4tverket.\r\n<h3><strong><b>6-4 Verifiera och s\u00e4kra alla ledningar<\/b><\/strong><\/h3>\r\nDubbelkontrollera alla anslutningar, dra \u00e5t skruvarna enligt tillverkarens specifikationer och se till att jordningen \u00e4r t\u00e4t.\r\n<h2><strong><b>7. Koordinering av \u00f6versp\u00e4nningsskydd av typ 1+2 med andra SPD<\/b><\/strong><\/h2>\r\n<h3><strong><b>7-1 F\u00f6rst\u00e5 \u00f6versp\u00e4nningsskyddshierarkin<\/b><\/strong><\/h3>\r\n<strong>Typ 1<\/strong>: Serviceing\u00e5ng (blixtskydd).\r\n\r\n<strong>Typ 2<\/strong>: Underf\u00f6rdelningstavlor (brytarskydd).\r\n\r\n<strong>Typ 3<\/strong>: Anv\u00e4ndningspunkter (k\u00e4nslig elektronik).\r\n<h3><strong><b>7-2 S\u00e4kerst\u00e4lla kompatibilitet med typ 3-enheter<\/b><\/strong><\/h3>\r\nV\u00e4lj SPD:er med matchande sp\u00e4nningsklasser och samordna energihanteringsf\u00f6rm\u00e5ga.\r\n<h3><strong><b>7-3 Undvika vanliga misstag<\/b><\/strong><\/h3>\r\nOverlapping protection zones\r\n\r\nUsing incompatible SPD types\r\n\r\nNeglecting proper grounding coordination\r\n<h2><strong><b>8. Underh\u00e5ll av \u00e5skskydd av typ 1+2<\/b><\/strong><\/h2>\r\n<h3><strong><b>8-1 Regelbunden inspektion av indikatorer<\/b><\/strong><\/h3>\r\nDe flesta SPD:er har visuella indikatorer (gr\u00f6n\/r\u00f6d). Kontrollera regelbundet f\u00f6r att bekr\u00e4fta driftstatus.\r\n<h3><strong><b>8-2 Testa och byta ut felaktiga enheter<\/b><\/strong><\/h3>\r\nOm avledaren visar fel eller har absorberat en kraftig \u00f6versp\u00e4nning, byt ut den omedelbart f\u00f6r att \u00e5terst\u00e4lla fullt skydd.\r\n<h3><strong><b>8-3 F\u00f6rl\u00e4nga livsl\u00e4ngden<\/b><\/strong><\/h3>\r\nH\u00e5ll rena anslutningar, \u00f6vervaka systemets jordning och schemal\u00e4gg \u00e5rliga underh\u00e5llskontroller.\r\n<h2><strong><b>9. Vanliga fr\u00e5gor<\/b><\/strong><\/h2>\r\n<strong>F1: Kan jag installera en blixtavledare av typ 1+2 sj\u00e4lv?<\/strong>\r\nS: Nej. Installationen ska alltid utf\u00f6ras av en licensierad elektriker f\u00f6r att s\u00e4kerst\u00e4lla s\u00e4kerhet och efterlevnad.\r\n\r\n<strong>F2: Beh\u00f6ver jag fortfarande typ 3 SPD om jag har en typ 1+2 avledare?<\/strong>\r\nA: Ja. Typ 1+2 ger ett brett skydd, men typ 3 \u00e4r avg\u00f6rande f\u00f6r k\u00e4nslig elektronisk utrustning.\r\n\r\n<strong>F3: Hur l\u00e4nge h\u00e5ller en avledare av typ 1+2?<\/strong>\r\nS: Vanligtvis 5\u201310 \u00e5r, beroende p\u00e5 \u00f6versp\u00e4nningsexponering. Regelbunden inspektion rekommenderas.\r\n<h2><strong><b>10. Slutsats<\/b><\/strong><\/h2>\r\nInstallera en <a href=\"https:\/\/www.britecelectric.com\/sv\/product-category\/ac-power-surge-protection\/type-1-2-lightning-surge-arrester\/\" target=\"_blank\" rel=\"noopener\"><strong>\u00c5sk\u00f6versp\u00e4nningsavledare av typ 1+2<\/strong><\/a>\u00a0\u00e4r ett viktigt steg f\u00f6r att uppn\u00e5 komplett <strong>\u00d6versp\u00e4nningsskydd f\u00f6r v\u00e4xelstr\u00f6m<\/strong>. Genom att noggrant planera installationen, s\u00e4kerst\u00e4lla korrekt jordning och koordinera med nedstr\u00f6ms SPD:er kan du skydda elektriska system mot b\u00e5de blixtnedslag och str\u00f6mbrytare. Med regelbundet underh\u00e5ll och korrekta installationsmetoder ger \u00f6versp\u00e4nningsavledare tillf\u00f6rlitligt, l\u00e5ngsiktigt skydd \u2013 minskar stillest\u00e5ndstiden, f\u00f6rhindrar skador p\u00e5 utrustningen och f\u00f6rb\u00e4ttrar den elektriska s\u00e4kerheten.","protected":false},"featured_media":2215,"parent":0,"menu_order":112,"template":"","meta":{"_acf_changed":false},"blog_category":[9],"class_list":["post-2214","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-industry-news"],"acf":{"des":"A Type 1+2 Lightning Surge Arrester protects electrical systems from lightning and switching surges, ensuring safety, reliability, and long-term AC power protection.","txt":"<h2><strong><b>1. Introduction<\/b><\/strong><\/h2>\r\nLightning strikes and switching surges pose a serious risk to modern electrical systems. Without proper protection, they can damage sensitive equipment, disrupt operations, and even cause fire hazards. Installing a <a href=\"https:\/\/www.britecelectric.com\/product-category\/ac-power-surge-protection\/type-1-2-lightning-surge-arrester\/\" target=\"_blank\" rel=\"noopener\"><strong>Type 1+2 Lightning Surge Arrester<\/strong><\/a>\u00a0is a highly effective way to provide <strong>AC Power Surge Protection<\/strong>, ensuring both safety and system reliability. This guide explains what Type 1+2 surge arresters are, how to install them correctly, and best practices for long-term performance.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product-category\/ac-power-surge-protection\/type-1-2-lightning-surge-arrester\/\" target=\"_blank\" rel=\"noopener\"><img class=\"alignnone size-full wp-image-2215\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2025\/09\/How-to-Install-Type-12-Lightning-Surge-Arresters.png\" alt=\"\" width=\"510\" height=\"510\" \/><\/a>\r\n<h2><strong><b>2. What is a Type 1+2 Lightning Surge Arrester?<\/b><\/strong><\/h2>\r\n<h3><strong><b>2-1 Definition and Working Principle<\/b><\/strong><\/h3>\r\nA<a href=\"https:\/\/www.britecelectric.com\/product-category\/ac-power-surge-protection\/type-1-2-lightning-surge-arrester\/\" target=\"_blank\" rel=\"noopener\"> <strong>Type 1+2 Lightning Surge Arrester<\/strong>\u00a0<\/a>is a protective device designed to safeguard electrical systems from high-energy lightning surges (Type 1) and lower-level switching surges (Type 2). It absorbs or diverts excess surge energy into the ground, keeping connected equipment safe.\r\n<h3><strong><b>2-2 Difference Between <a href=\"https:\/\/www.britecelectric.com\/product-category\/ac-power-surge-protection\/type-1-2-lightning-surge-arrester\/\" target=\"_blank\" rel=\"noopener\">Type 1 and Type 2 Protection<\/a><\/b><\/strong><\/h3>\r\n<strong>Type 1 Surge Arrester<\/strong>: Installed at the main service entrance, designed to handle direct lightning currents.\r\n\r\n<strong>Type 2 Surge Arrester<\/strong>: Installed downstream, protecting against switching surges and residual lightning energy.\r\n\r\n<strong>Type 1+2 Combination<\/strong>: Provides both levels of protection in a single device, ensuring full coverage.\r\n<h2><strong><b>3. Planning for Installation<\/b><\/strong><\/h2>\r\n<h3><strong><b>3-1 Evaluating the Electrical System and Surge Risks<\/b><\/strong><\/h3>\r\nAssess the power distribution system, identify high-risk areas (e.g., service entrance, outdoor equipment), and determine required surge current ratings.\r\n<h3><strong><b>3-2 Selecting the Correct Arrester Model<\/b><\/strong><\/h3>\r\nChoose an arrester with appropriate <strong>voltage rating<\/strong>, <strong>surge current capacity<\/strong>, and compliance with IEC\/UL standards.\r\n<h3><strong><b>3-3 Preparing Tools and Safety Equipment<\/b><\/strong><\/h3>\r\nBefore installation, gather insulated tools, protective gloves, and testing equipment. Always follow electrical safety regulations.\r\n<h2><strong><b>4. Placement and Positioning of Surge Arresters<\/b><\/strong><\/h2>\r\n<h3><strong><b>4-1 Recommended Installation Location<\/b><\/strong><\/h3>\r\nThe best location for a <strong>Type 1+2 Lightning Surge Arrester<\/strong>\u00a0is at the <strong>main service entrance<\/strong>, where surges first enter the building.\r\n<h3><strong><b>4-2 Coordination with Downstream SPDs<\/b><\/strong><\/h3>\r\nFor maximum protection, coordinate with Type 3 SPDs installed close to sensitive equipment (computers, servers, medical devices).\r\n<h3><strong><b>4-3 Ensuring Optimal Distance from Sensitive Equipment<\/b><\/strong><\/h3>\r\nShorter wiring between arrester and equipment reduces impedance, improving protection efficiency.\r\n<h2><strong><b>5. Proper Grounding for Surge Arresters<\/b><\/strong><\/h2>\r\n<h3><strong><b>5-1 Importance of a Low-Impedance Grounding System<\/b><\/strong><\/h3>\r\nEffective surge protection depends on a <strong>solid and low-resistance grounding network<\/strong>. High impedance can reduce arrester performance.\r\n<h3><strong><b>5-2 Methods for Connecting the Arrester<\/b><\/strong><\/h3>\r\nUse short, thick conductors to connect the arrester to the ground busbar or grounding electrode. Avoid sharp bends in cables.\r\n<h3><strong><b>5-3 Compliance with Standards<\/b><\/strong><\/h3>\r\nEnsure grounding practices meet <strong>local electrical codes<\/strong>\u00a0(e.g., IEC 62305, NEC).\r\n<h2><strong><b>6. Step-by-Step Installation Guide<\/b><\/strong><\/h2>\r\n<h3><strong><b>6-1 Turning Off Power and Safety Precautions<\/b><\/strong><\/h3>\r\nBefore installation, disconnect power supply and verify system is de-energized.\r\n<h3><strong><b>6-2 Mounting the <a href=\"https:\/\/www.britecelectric.com\/product-category\/ac-power-surge-protection\/type-1-2-lightning-surge-arrester\/\" target=\"_blank\" rel=\"noopener\">Type 1+2 Surge Arrester<\/a><\/b><\/strong><\/h3>\r\nSecure the arrester on a DIN rail or panel mount in the distribution board.\r\n<h3><strong><b>6-3 Connecting Line, Neutral, and Grounding Terminals<\/b><\/strong><\/h3>\r\nConnect <strong>phase lines<\/strong>\u00a0(L) to the arrester\u2019s line terminals.\r\n\r\nConnect <strong>neutral (N)<\/strong>\u00a0if required by the arrester design.\r\n\r\nConnect <strong>ground (PE)<\/strong>\u00a0directly to the grounding network.\r\n<h3><strong><b>6-4 Verifying and Securing All Wiring<\/b><\/strong><\/h3>\r\nDouble-check all connections, torque screws to manufacturer specifications, and ensure tight grounding.\r\n<h2><strong><b>7. Coordinating Type 1+2 Surge Arresters with Other SPDs<\/b><\/strong><\/h2>\r\n<h3><strong><b>7-1 Understanding Surge Protection Hierarchy<\/b><\/strong><\/h3>\r\n<strong>Type 1<\/strong>: Service entrance (lightning protection).\r\n\r\n<strong>Type 2<\/strong>: Sub-distribution boards (switching protection).\r\n\r\n<strong>Type 3<\/strong>: Point-of-use devices (sensitive electronics).\r\n<h3><strong><b>7-2 Ensuring Compatibility with Type 3 Devices<\/b><\/strong><\/h3>\r\nSelect SPDs with matching voltage ratings and coordinate energy-handling capabilities.\r\n<h3><strong><b>7-3 Avoiding Common Mistakes<\/b><\/strong><\/h3>\r\nOverlapping protection zones\r\n\r\nUsing incompatible SPD types\r\n\r\nNeglecting proper grounding coordination\r\n<h2><strong><b>8. Maintaining Type 1+2 Lightning Surge Arresters<\/b><\/strong><\/h2>\r\n<h3><strong><b>8-1 Periodic Inspection of Indicators<\/b><\/strong><\/h3>\r\nMost SPDs have visual indicators (green\/red). Check regularly to confirm operational status.\r\n<h3><strong><b>8-2 Testing and Replacing Faulty Units<\/b><\/strong><\/h3>\r\nIf the arrester shows failure or has absorbed a major surge, replace it immediately to restore full protection.\r\n<h3><strong><b>8-3 Extending Service Life<\/b><\/strong><\/h3>\r\nMaintain clean connections, monitor system grounding, and schedule annual maintenance checks.\r\n<h2><strong><b>9. FAQ<\/b><\/strong><\/h2>\r\n<strong>Q1: Can I install a Type 1+2 Lightning Surge Arrester by myself?<\/strong>\r\nA: No. Installation should always be performed by a licensed electrician to ensure safety and compliance.\r\n\r\n<strong>Q2: Do I still need Type 3 SPDs if I have a Type 1+2 arrester?<\/strong>\r\nA: Yes. Type 1+2 provides broad protection, but Type 3 is essential for sensitive electronic equipment.\r\n\r\n<strong>Q3: How long does a Type 1+2 arrester last?<\/strong>\r\nA: Typically 5\u201310 years, depending on surge exposure. Regular inspection is recommended.\r\n<h2><strong><b>10. Conclusion<\/b><\/strong><\/h2>\r\nInstalling a <a href=\"https:\/\/www.britecelectric.com\/product-category\/ac-power-surge-protection\/type-1-2-lightning-surge-arrester\/\" target=\"_blank\" rel=\"noopener\"><strong>Type 1+2 Lightning Surge Arrester<\/strong><\/a>\u00a0is a vital step in achieving complete <strong>AC Power Surge Protection<\/strong>. By carefully planning the installation, ensuring proper grounding, and coordinating with downstream SPDs, you can safeguard electrical systems against both lightning strikes and switching surges. With regular maintenance and correct installation practices, surge arresters provide reliable, long-term protection\u2014reducing downtime, preventing equipment damage, and enhancing electrical safety."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/blog\/2214","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/media\/2215"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/media?parent=2214"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/sv\/wp-json\/wp\/v2\/blog_category?post=2214"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}