{"id":2388,"date":"2026-03-26T09:03:47","date_gmt":"2026-03-26T01:03:47","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=2388"},"modified":"2026-03-24T10:25:00","modified_gmt":"2026-03-24T02:25:00","slug":"do-you-need-type-1-spd-in-lightning-prone-regions","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/ru\/blog\/do-you-need-type-1-spd-in-lightning-prone-regions\/","title":{"rendered":"Do You Need Type 1 SPD In Lightning-Prone Regions?"},"content":{"rendered":"In regions where thunderstorms are frequent, electrical systems face constant risk from surge events. <a href=\"https:\/\/www.britecelectric.com\/ru\/product-category\/ac-power-surge-protection\/type-1-lightning-surge-protection-device\/\"><strong><span style=\"color: #009292;\">\u0422\u0438\u043f 1 \u0421\u041f\u0414<\/span><\/strong><\/a> plays a critical role in protecting infrastructure from lightning-induced damage. Whether you are sourcing a <strong>type 1 SPD single phase<\/strong> or evaluating <strong>type 1 SPD 3 phase<\/strong> solutions, understanding their importance helps ensure system stability, safety, and long-term cost savings.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/ru\/product\/br-25vg-11-25ka-type-1-surge-protector\/\"><img class=\"alignnone size-full wp-image-1634\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-11-1.jpg\" alt=\"BR-25VG 1+1 25 \u043a\u0410 \u0422\u0438\u043f 1 \u0423\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f\" width=\"800\" \/><\/a>\r\n\r\n&nbsp;\r\n<h2>Do You Need Type 1 SPD In Lightning-Prone Regions?<\/h2>\r\n<h3>Impact Of Lightning Surge Voltage On Equipment<\/h3>\r\nLightning strikes generate extremely high transient voltages that can travel through power lines and distribution systems in milliseconds. These surges often exceed the insulation capacity of electrical equipment, leading to catastrophic failures. Without a properly installed <strong>type 1 SPD<\/strong>, sensitive devices such as PLC systems, inverters, and communication equipment are exposed to irreversible damage.\r\n\r\nIn industrial environments, even a short disruption can trigger a chain reaction\u2014equipment shutdown, data loss, and production delays. The role of a <strong>SPD single phase<\/strong> or three-phase system becomes essential in maintaining operational continuity.\r\n<h3>Statistics On High-Risk Areas\/Common Cases<\/h3>\r\nLightning-prone regions such as Southeast Asia, parts of Africa, and South America report millions of lightning strikes annually. Facilities located in open areas, near tall structures, or with poor grounding systems are especially vulnerable. Real-world data shows that companies without <strong>type 1 SPD 3 phase<\/strong> protection experience significantly higher maintenance costs and equipment replacement rates.\r\n\r\nA manufacturing client in Southeast Asia experienced repeated inverter failures during monsoon seasons. After installing a <strong>type 1 SPD single phase<\/strong> system at the service entrance, equipment failure rates dropped dramatically\u2014almost overnight.\r\n<h3>How Type 1 SPD Absorbs Surge Current And Protects The System<\/h3>\r\nT<strong>ype 1 SPD<\/strong> operates by diverting high-energy surge currents safely to ground. Installed at the main distribution board, it acts as the first barrier against lightning energy. The device responds within nanoseconds, limiting voltage spikes and preventing them from propagating downstream.\r\n\r\nThis process not only protects connected equipment but also stabilizes the entire electrical network. When coordinated with downstream devices, such as Type 2 SPDs, the protection becomes layered and far more effective.\r\n\r\n&nbsp;\r\n<h2>Key Benefits Of Type 1 SPD Single Phase<\/h2>\r\nFor many commercial and residential applications, a <strong>type 1 SPD single phase<\/strong> offers a practical and efficient solution. It ensures reliable protection for low-voltage systems while maintaining cost-effectiveness.\r\n\r\n<strong>Reliable first-line defense<\/strong> is one of the most significant advantages, as it intercepts high-energy surges before they enter the internal wiring system. <em>This early intervention is crucial<\/em> in preventing cascading failures.\r\n\r\nAnother important benefit is <strong>extended equipment lifespan<\/strong>. By minimizing repeated stress from transient voltages, electrical devices operate more consistently over time.\r\n\r\nAdditionally, <strong>reduced downtime<\/strong> becomes a tangible business advantage. Facilities can maintain productivity even during adverse weather conditions.\r\n\r\nFinally, <strong>enhanced safety performance<\/strong> helps reduce risks of electrical fires and insulation breakdown, ensuring compliance with international safety standards.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/ru\/product\/br-25vg-31-25ka-class-i-type-1-spd-power-surge-protection-device\/\"><img class=\"alignnone size-full wp-image-1631\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-31-2.jpg\" alt=\"BR-25VG 3+1, 25 \u043a\u0410, \u0423\u0417\u0418\u041f \u043a\u043b\u0430\u0441\u0441\u0430 I, \u0442\u0438\u043f 1, \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u0441\u043a\u0430\u0447\u043a\u043e\u0432 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f\" width=\"800\" \/><\/a>\r\n\r\n&nbsp;\r\n<h2>How To Choose The Right Type 1 SPD<\/h2>\r\nSelecting the appropriate <strong>type 1 SPD<\/strong> requires a careful evaluation of technical parameters and application scenarios. Buyers should focus on aligning product specifications with real-world operating conditions.\r\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"8\">\r\n<tbody>\r\n<tr>\r\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\r\n<th>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/th>\r\n<th>Importance<\/th>\r\n<th>Single Phase<\/th>\r\n<th>3 Phase<\/th>\r\n<\/tr>\r\n<tr>\r\n<td>Imax<\/td>\r\n<td>\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u0440\u0430\u0437\u0440\u044f\u0434\u0430<\/td>\r\n<td>Determines surge handling capacity<\/td>\r\n<td>25\u201350kA<\/td>\r\n<td>50\u2013100kA<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>\u0412\u0432\u0435\u0440\u0445<\/td>\r\n<td>\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u0437\u0430\u0449\u0438\u0442\u044b \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f<\/td>\r\n<td>Lower value = better protection<\/td>\r\n<td>\u22642,5 \u043a\u0412<\/td>\r\n<td>\u22642,5 \u043a\u0412<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>System Type<\/td>\r\n<td>Electrical configuration<\/td>\r\n<td>Compatibility<\/td>\r\n<td>Single phase<\/td>\r\n<td>3 phase<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>\u0412\u0440\u0435\u043c\u044f \u043e\u0442\u0432\u0435\u0442\u0430<\/td>\r\n<td>Reaction speed<\/td>\r\n<td>Faster = safer<\/td>\r\n<td>&lt;25ns<\/td>\r\n<td>&lt;25ns<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\nA well-chosen <strong>type 1 SPD 3 phase<\/strong> is essential for industrial facilities with heavy machinery, while a <strong>SPD single phase<\/strong> is more suitable for smaller systems. Always verify compliance with IEC or UL standards to ensure product reliability.\r\n\r\n&nbsp;\r\n<h2>Type 1 SPD Installation<\/h2>\r\nCorrect installation is just as important as selecting the right device. A <strong>type 1 SPD<\/strong> should always be installed at the main service entrance to intercept surges before they enter the internal network.\r\n\r\nProper grounding is absolutely critical. Without an effective grounding system, even the best <strong>type 1 SPD single phase<\/strong> cannot perform optimally. Keeping connection leads short and straight further enhances performance by reducing inductive impedance.\r\n\r\nIn practice, many failures are not due to product quality but improper installation. Working with experienced electricians ensures that the SPD system delivers its full protective capability.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/ru\/product\/br-25vg-1p-25ka-type-123-surge-protection-devices\/\"><img class=\"alignnone size-full wp-image-1628\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-1P-1.jpg\" alt=\"\u0411\u0420-25\u0412\u0413 1\u041f 25\u043a\u0410 \u0422\u0438\u043f 1+2+3 \u0423\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f\" width=\"800\" \/><\/a>\r\n\r\n&nbsp;\r\n<h2>\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b<\/h2>\r\n<strong>Type 1 SPD 3 Phase\u200b Vs Type 1 SPD Single Phase\u200b<\/strong>\r\nThe main difference lies in application. A <strong>type 1 SPD 3 phase<\/strong> is designed for industrial and commercial systems, while a <strong>type 1 SPD single phase<\/strong> suits residential or small business use.\r\n\r\n<strong>Type 1 Vs Type 2 SPD<\/strong>\r\nA <strong>type 1 SPD<\/strong> handles direct lightning surges at the service entrance, whereas Type 2 protects downstream circuits from residual surges.\r\n\r\n<strong>Where Can I Buy Certified Type 1 SPD Devices?<\/strong>\r\nYou can source certified products directly from manufacturers like Britec Electric, ensuring compliance with IEC and UL standards.\r\n\r\n<strong>Are There International Standards For Type 1 SPD?<\/strong>\r\nYes, the most common standards include IEC 61643-11 and UL 1449.\r\n\r\n<strong>Do I Need Type 1 SPD If I Already Have Type 2 SPD?<\/strong>\r\nYes, Type 1 provides primary protection, while Type 2 offers secondary protection.\r\n\r\n<strong>How Do I Choose The Right Type 1 SPD For My Region?<\/strong>\r\nConsider lightning frequency, grid stability, and required discharge capacity.\r\n\r\n<strong>Is Grounding Important For Type 1 SPD Effectiveness?<\/strong>\r\nAbsolutely, grounding is essential for proper surge dissipation.\r\n\r\n<strong>Can Type 1 SPD Protect Sensitive Electrical Equipment?<\/strong>\r\nYes, it significantly reduces voltage spikes reaching sensitive devices.\r\n\r\n<strong>Can Type 1 SPD Reduce Downtime After A Lightning Strike?<\/strong>\r\nYes, it minimizes damage and speeds up system recovery.\r\n\r\n<strong>What Is The Maximum Discharge Current (Imax) In Type 1 SPD?<\/strong>\r\nIt represents the highest surge current the SPD can safely handle.\r\n\r\n&nbsp;\r\n<h2>\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h2>\r\nIn lightning-prone regions, investing in a <strong>type 1 SPD<\/strong> is not just a precaution\u2014it is a strategic decision. From protecting critical infrastructure to reducing costly downtime, the benefits are clear and measurable. Whether you require a <strong>type 1 SPD single phase<\/strong> for small-scale applications or a <strong>type 1 SPD 3 phase<\/strong> for industrial systems, choosing the right solution ensures long-term reliability.\r\n\r\nAt Britec Electric, we understand the real challenges faced by global buyers. Our surge protection solutions are designed to meet international standards while delivering consistent performance in demanding environments. If you are looking to enhance system safety and reliability, now is the time to act. Contact Britec Electric today to explore tailored solutions and request a competitive quote.","protected":false},"featured_media":1634,"parent":0,"menu_order":68,"template":"","meta":{"_acf_changed":false},"blog_category":[9],"class_list":["post-2388","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-industry-news"],"acf":{"des":"In regions where thunderstorms are frequent, electrical systems face constant risk from surge events. Type 1 SPD plays a critical role in protecting infrastructure from lightning-induced damage.","txt":"In regions where thunderstorms are frequent, electrical systems face constant risk from surge events. <a href=\"https:\/\/www.britecelectric.com\/product-category\/ac-power-surge-protection\/type-1-lightning-surge-protection-device\/\"><strong><span style=\"color: #009292;\">Type 1 SPD<\/span><\/strong><\/a> plays a critical role in protecting infrastructure from lightning-induced damage. Whether you are sourcing a <strong>type 1 SPD single phase<\/strong> or evaluating <strong>type 1 SPD 3 phase<\/strong> solutions, understanding their importance helps ensure system stability, safety, and long-term cost savings.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-25vg-11-25ka-type-1-surge-protector\/\"><img class=\"alignnone size-full wp-image-1634\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-11-1.jpg\" alt=\"BR-25VG 1+1 25kA Type 1 Surge Protector\" width=\"800\" \/><\/a>\r\n\r\n&nbsp;\r\n<h2>Do You Need Type 1 SPD In Lightning-Prone Regions?<\/h2>\r\n<h3>Impact Of Lightning Surge Voltage On Equipment<\/h3>\r\nLightning strikes generate extremely high transient voltages that can travel through power lines and distribution systems in milliseconds. These surges often exceed the insulation capacity of electrical equipment, leading to catastrophic failures. Without a properly installed <strong>type 1 SPD<\/strong>, sensitive devices such as PLC systems, inverters, and communication equipment are exposed to irreversible damage.\r\n\r\nIn industrial environments, even a short disruption can trigger a chain reaction\u2014equipment shutdown, data loss, and production delays. The role of a <strong>SPD single phase<\/strong> or three-phase system becomes essential in maintaining operational continuity.\r\n<h3>Statistics On High-Risk Areas\/Common Cases<\/h3>\r\nLightning-prone regions such as Southeast Asia, parts of Africa, and South America report millions of lightning strikes annually. Facilities located in open areas, near tall structures, or with poor grounding systems are especially vulnerable. Real-world data shows that companies without <strong>type 1 SPD 3 phase<\/strong> protection experience significantly higher maintenance costs and equipment replacement rates.\r\n\r\nA manufacturing client in Southeast Asia experienced repeated inverter failures during monsoon seasons. After installing a <strong>type 1 SPD single phase<\/strong> system at the service entrance, equipment failure rates dropped dramatically\u2014almost overnight.\r\n<h3>How Type 1 SPD Absorbs Surge Current And Protects The System<\/h3>\r\nT<strong>ype 1 SPD<\/strong> operates by diverting high-energy surge currents safely to ground. Installed at the main distribution board, it acts as the first barrier against lightning energy. The device responds within nanoseconds, limiting voltage spikes and preventing them from propagating downstream.\r\n\r\nThis process not only protects connected equipment but also stabilizes the entire electrical network. When coordinated with downstream devices, such as Type 2 SPDs, the protection becomes layered and far more effective.\r\n\r\n&nbsp;\r\n<h2>Key Benefits Of Type 1 SPD Single Phase<\/h2>\r\nFor many commercial and residential applications, a <strong>type 1 SPD single phase<\/strong> offers a practical and efficient solution. It ensures reliable protection for low-voltage systems while maintaining cost-effectiveness.\r\n\r\n<strong>Reliable first-line defense<\/strong> is one of the most significant advantages, as it intercepts high-energy surges before they enter the internal wiring system. <em>This early intervention is crucial<\/em> in preventing cascading failures.\r\n\r\nAnother important benefit is <strong>extended equipment lifespan<\/strong>. By minimizing repeated stress from transient voltages, electrical devices operate more consistently over time.\r\n\r\nAdditionally, <strong>reduced downtime<\/strong> becomes a tangible business advantage. Facilities can maintain productivity even during adverse weather conditions.\r\n\r\nFinally, <strong>enhanced safety performance<\/strong> helps reduce risks of electrical fires and insulation breakdown, ensuring compliance with international safety standards.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-25vg-31-25ka-class-i-type-1-spd-power-surge-protection-device\/\"><img class=\"alignnone size-full wp-image-1631\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-31-2.jpg\" alt=\"BR-25VG 3+1 25kA Class I Type 1 SPD Power Surge Protection Device\" width=\"800\" \/><\/a>\r\n\r\n&nbsp;\r\n<h2>How To Choose The Right Type 1 SPD<\/h2>\r\nSelecting the appropriate <strong>type 1 SPD<\/strong> requires a careful evaluation of technical parameters and application scenarios. Buyers should focus on aligning product specifications with real-world operating conditions.\r\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"8\">\r\n<tbody>\r\n<tr>\r\n<th>Parameter<\/th>\r\n<th>Description<\/th>\r\n<th>Importance<\/th>\r\n<th>Single Phase<\/th>\r\n<th>3 Phase<\/th>\r\n<\/tr>\r\n<tr>\r\n<td>Imax<\/td>\r\n<td>Maximum discharge current<\/td>\r\n<td>Determines surge handling capacity<\/td>\r\n<td>25\u201350kA<\/td>\r\n<td>50\u2013100kA<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Up<\/td>\r\n<td>Voltage protection level<\/td>\r\n<td>Lower value = better protection<\/td>\r\n<td>\u22642.5kV<\/td>\r\n<td>\u22642.5kV<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>System Type<\/td>\r\n<td>Electrical configuration<\/td>\r\n<td>Compatibility<\/td>\r\n<td>Single phase<\/td>\r\n<td>3 phase<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Response Time<\/td>\r\n<td>Reaction speed<\/td>\r\n<td>Faster = safer<\/td>\r\n<td>&lt;25ns<\/td>\r\n<td>&lt;25ns<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\nA well-chosen <strong>type 1 SPD 3 phase<\/strong> is essential for industrial facilities with heavy machinery, while a <strong>SPD single phase<\/strong> is more suitable for smaller systems. Always verify compliance with IEC or UL standards to ensure product reliability.\r\n\r\n&nbsp;\r\n<h2>Type 1 SPD Installation<\/h2>\r\nCorrect installation is just as important as selecting the right device. A <strong>type 1 SPD<\/strong> should always be installed at the main service entrance to intercept surges before they enter the internal network.\r\n\r\nProper grounding is absolutely critical. Without an effective grounding system, even the best <strong>type 1 SPD single phase<\/strong> cannot perform optimally. Keeping connection leads short and straight further enhances performance by reducing inductive impedance.\r\n\r\nIn practice, many failures are not due to product quality but improper installation. Working with experienced electricians ensures that the SPD system delivers its full protective capability.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-25vg-1p-25ka-type-123-surge-protection-devices\/\"><img class=\"alignnone size-full wp-image-1628\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-1P-1.jpg\" alt=\"BR-25VG 1P 25kA Type 1+2+3 Surge Protection Devices\" width=\"800\" \/><\/a>\r\n\r\n&nbsp;\r\n<h2>FAQ<\/h2>\r\n<strong>Type 1 SPD 3 Phase\u200b Vs Type 1 SPD Single Phase\u200b<\/strong>\r\nThe main difference lies in application. A <strong>type 1 SPD 3 phase<\/strong> is designed for industrial and commercial systems, while a <strong>type 1 SPD single phase<\/strong> suits residential or small business use.\r\n\r\n<strong>Type 1 Vs Type 2 SPD<\/strong>\r\nA <strong>type 1 SPD<\/strong> handles direct lightning surges at the service entrance, whereas Type 2 protects downstream circuits from residual surges.\r\n\r\n<strong>Where Can I Buy Certified Type 1 SPD Devices?<\/strong>\r\nYou can source certified products directly from manufacturers like Britec Electric, ensuring compliance with IEC and UL standards.\r\n\r\n<strong>Are There International Standards For Type 1 SPD?<\/strong>\r\nYes, the most common standards include IEC 61643-11 and UL 1449.\r\n\r\n<strong>Do I Need Type 1 SPD If I Already Have Type 2 SPD?<\/strong>\r\nYes, Type 1 provides primary protection, while Type 2 offers secondary protection.\r\n\r\n<strong>How Do I Choose The Right Type 1 SPD For My Region?<\/strong>\r\nConsider lightning frequency, grid stability, and required discharge capacity.\r\n\r\n<strong>Is Grounding Important For Type 1 SPD Effectiveness?<\/strong>\r\nAbsolutely, grounding is essential for proper surge dissipation.\r\n\r\n<strong>Can Type 1 SPD Protect Sensitive Electrical Equipment?<\/strong>\r\nYes, it significantly reduces voltage spikes reaching sensitive devices.\r\n\r\n<strong>Can Type 1 SPD Reduce Downtime After A Lightning Strike?<\/strong>\r\nYes, it minimizes damage and speeds up system recovery.\r\n\r\n<strong>What Is The Maximum Discharge Current (Imax) In Type 1 SPD?<\/strong>\r\nIt represents the highest surge current the SPD can safely handle.\r\n\r\n&nbsp;\r\n<h2>Conclusion<\/h2>\r\nIn lightning-prone regions, investing in a <strong>type 1 SPD<\/strong> is not just a precaution\u2014it is a strategic decision. From protecting critical infrastructure to reducing costly downtime, the benefits are clear and measurable. Whether you require a <strong>type 1 SPD single phase<\/strong> for small-scale applications or a <strong>type 1 SPD 3 phase<\/strong> for industrial systems, choosing the right solution ensures long-term reliability.\r\n\r\nAt Britec Electric, we understand the real challenges faced by global buyers. Our surge protection solutions are designed to meet international standards while delivering consistent performance in demanding environments. If you are looking to enhance system safety and reliability, now is the time to act. Contact Britec Electric today to explore tailored solutions and request a competitive quote."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/ru\/wp-json\/wp\/v2\/blog\/2388","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/ru\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/ru\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/ru\/wp-json\/wp\/v2\/media\/1634"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/ru\/wp-json\/wp\/v2\/media?parent=2388"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/ru\/wp-json\/wp\/v2\/blog_category?post=2388"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}