{"id":840,"date":"2023-12-18T15:04:36","date_gmt":"2023-12-18T07:04:36","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=840"},"modified":"2024-09-05T16:32:14","modified_gmt":"2024-09-05T08:32:14","slug":"standards-related-to-surge-protection-devices","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/pt\/blog\/standards-related-to-surge-protection-devices\/","title":{"rendered":"Padr\u00f5es relacionados a dispositivos de prote\u00e7\u00e3o contra surtos"},"content":{"rendered":"<strong>CEI\/EN 61643-11:2011\u00a0<\/strong>\r\n<strong>Dispositivos de prote\u00e7\u00e3o contra surtos de baixa tens\u00e3o \u2013 Parte 11: Dispositivos de prote\u00e7\u00e3o contra surtos conectados a sistemas de energia de baixa tens\u00e3o \u2013 Requisitos e m\u00e9todos de teste<\/strong>\r\n\r\nA IEC 61643-11:2011 \u00e9 aplic\u00e1vel a dispositivos para prote\u00e7\u00e3o contra surtos contra efeitos indiretos e diretos de raios ou outras sobretens\u00f5es transit\u00f3rias. Esses dispositivos s\u00e3o embalados para serem conectados a 50\/60 Hz a.c. circuitos de energia e equipamentos com classifica\u00e7\u00e3o de at\u00e9 1.000 V r.m.s. Caracter\u00edsticas de desempenho, m\u00e9todos padr\u00e3o para testes e classifica\u00e7\u00f5es s\u00e3o estabelecidos. Esses dispositivos cont\u00eam pelo menos um componente n\u00e3o linear e destinam-se a limitar surtos de tens\u00e3o e desviar correntes de surto. Esta primeira edi\u00e7\u00e3o do IEC61643-11 cancela e substitui a segunda edi\u00e7\u00e3o da IEC 61643-1 publicada em 2005. As principais mudan\u00e7as em rela\u00e7\u00e3o \u00e0 segunda edi\u00e7\u00e3o da IEC 61643-1 s\u00e3o a reestrutura\u00e7\u00e3o completa e melhoria dos procedimentos e sequ\u00eancias de teste.\r\n\r\n<strong>IEC 61643-21:2000\/AMD2:2012\u00a0<\/strong>\r\n<strong>Dispositivos de prote\u00e7\u00e3o contra surtos de baixa tens\u00e3o \u2013 Parte 21: Dispositivos de prote\u00e7\u00e3o contra surtos conectados a redes de telecomunica\u00e7\u00f5es e sinaliza\u00e7\u00e3o \u2013 Requisitos de desempenho e m\u00e9todos de teste<\/strong>\r\n\r\n<strong>IEC 61643-12:2020\u00a0<\/strong>\r\n<strong>Dispositivos de prote\u00e7\u00e3o contra surtos de baixa tens\u00e3o \u2013 Parte 12: Dispositivos de prote\u00e7\u00e3o contra surtos conectados a sistemas de energia de baixa tens\u00e3o \u2013 Princ\u00edpios de sele\u00e7\u00e3o e aplica\u00e7\u00e3o<\/strong>\r\n\r\nIEC 61643-12:2020 describes the principles for the selection, operation, location and coordination of SPDs to be connected to 50\/60 Hz AC power circuits, and equipment rated up to 1 000 V RMS. These devices contain at least one non-linear component and are intended to limit surge voltages and divert surge currents.\r\nNOTE 1 Additional requirements for special applications are also applicable, If required.\r\nNOTE 2 IEC 60364 and IEC 62305-4 are also applicable.\r\nNOTE 3 This standard deal only with SPDs and not with surge protection components\r\n\r\n<strong>CEI 61643-22:2015\u00a0<\/strong>\r\n<strong>Dispositivos de prote\u00e7\u00e3o contra surtos de baixa tens\u00e3o \u2013 Parte 22: Dispositivos de prote\u00e7\u00e3o contra surtos conectados a redes de telecomunica\u00e7\u00f5es e sinaliza\u00e7\u00e3o \u2013 Princ\u00edpios de sele\u00e7\u00e3o e aplica\u00e7\u00e3o<\/strong>\r\n\r\nIEC 61643-22:2015 describes the principles for the selection, operation, location and coordination of SPDs connected to telecommunication and signalling networks with nominal system voltages up to 1 000 V r.m.s. a.c. and 1 500 V d.c. This standard also addresses SPDs that incorporate protection for signalling lines and power lines in the same enclosure (so called multiservice SPDs). This second edition cancels and replaces the first edition published in 2004. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:\r\n\u2013 Update the use of multiservice SPDs (Article 8);\r\n\u2013 Comparison between SPD classification of IEC 61643-11 and IEC 61643-21 (7.3.3);\r\n\u2013 Consideration of new transmission systems as PoE (Annex F);\r\n\u2013 EMC requirements of SPDs (Annex G);\r\n\u2013 Maintenance cycles of SPDs (Annex I). Keywords: SPD, surge protective devices\r\n\r\n<strong>IEC 61643-31:2018\u00a0<\/strong>\r\n<strong>Dispositivos de prote\u00e7\u00e3o contra surtos de baixa tens\u00e3o \u2013 Parte 31: Requisitos e m\u00e9todos de teste para SPDs para instala\u00e7\u00f5es fotovoltaicas<\/strong>\r\n\r\nA IEC 61643-31:2018 \u00e9 aplic\u00e1vel a dispositivos de prote\u00e7\u00e3o contra surtos (SPDs), destinados \u00e0 prote\u00e7\u00e3o contra surtos contra efeitos indiretos e diretos de raios ou outras sobretens\u00f5es transit\u00f3rias. Esses dispositivos s\u00e3o projetados para serem conectados ao lado CC de instala\u00e7\u00f5es fotovoltaicas com tens\u00e3o nominal de at\u00e9 1.500 V CC. Esses dispositivos cont\u00eam pelo menos um componente n\u00e3o linear e destinam-se a limitar sobretens\u00f5es e desviar correntes de sobretens\u00e3o. Caracter\u00edsticas de desempenho, requisitos de seguran\u00e7a, m\u00e9todos padr\u00e3o para testes eclassifica\u00e7\u00f5es s\u00e3o estabelecidas. Os SPDs que atendem a esta norma s\u00e3o exclusivamente dedicados \u00e0 instala\u00e7\u00e3o no lado CC dos geradores fotovoltaicos e no lado CC dos inversores. Os SPD para sistemas fotovoltaicos com armazenamento de energia (por exemplo, baterias, bancos de condensadores) n\u00e3o s\u00e3o abrangidos. Os SPDs com terminais de entrada e sa\u00edda separados que cont\u00eam imped\u00e2ncia em s\u00e9rie espec\u00edfica entre esses terminais (os chamados SPDs de duas portas de acordo com a IEC 61643-11:2011) n\u00e3o s\u00e3o cobertos. Os SPDs compat\u00edveis com esta norma s\u00e3o projetados paraestar permanentemente conectado onde a conex\u00e3o e desconex\u00e3o de SPDs fixos s\u00f3 podem ser feitas por meio de uma ferramenta. Esta norma n\u00e3o se aplica a SPDs port\u00e1teis.\r\n\r\n<strong>IEC 61643-32:2017\u00a0<\/strong>\r\n<strong>Dispositivos de prote\u00e7\u00e3o contra surtos de baixa tens\u00e3o \u2013 Parte 32: Dispositivos de prote\u00e7\u00e3o contra surtos conectados \u00e0 rede CC. lado das instala\u00e7\u00f5es fotovoltaicas \u2013 Princ\u00edpios de sele\u00e7\u00e3o e aplica\u00e7\u00e3o<\/strong>\r\n\r\nA IEC 61643-32:2017 descreve os princ\u00edpios para sele\u00e7\u00e3o, instala\u00e7\u00e3o e coordena\u00e7\u00e3o de SPDs destinados ao uso em sistemas fotovoltaicos (PV) de at\u00e9 1.500 V CC e para o lado CA do sistema fotovoltaico classificado at\u00e9 1.000 V rms 50\/60 Hz. A instala\u00e7\u00e3o fotovoltaica estende-se desde um conjunto fotovoltaico ou um conjunto de m\u00f3dulos fotovoltaicos interconectados para incluir o cabeamento associado e os dispositivos de prote\u00e7\u00e3o e o inversor at\u00e9 o ponto de conex\u00e3o no quadro de distribui\u00e7\u00e3o ou no ponto de alimenta\u00e7\u00e3o da rede el\u00e9trica. Esta parte da IEC 61643considera SPDs usados \u200b\u200bem diferentes locais e em diferentes tipos de sistemas fotovoltaicos: Sistemas fotovoltaicos localizados no topo de um edif\u00edcio. Sistemas fotovoltaicos localizados no solo, como usinas de campo livre, caracterizados por m\u00faltiplos aterramentos e um sistema de aterramento em malha. O termo instala\u00e7\u00e3o fotovoltaica \u00e9 usado para se referir a ambos os tipos de sistemas fotovoltaicos. O termo usina fotovoltaica \u00e9 usado apenas para sistemas de energia multiaterrados de campo livre estendidos localizados no solo. Para instala\u00e7\u00f5es fotovoltaicas incluindo requisitos adicionais de bateriaspode ser necess\u00e1rio.\r\n\r\n<strong>IEC 62561-1:2017 RLV\u00a0<\/strong>\r\n<strong>Vers\u00e3o redline<\/strong>\r\n<strong>Componentes do sistema de prote\u00e7\u00e3o contra raios (LPSC) \u2013 Parte 1: Requisitos para componentes de conex\u00e3o<\/strong>\r\n\r\nIEC 62561-1:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is not an official document, it is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.\r\n\r\nIEC 62561-1:2017 specifies the requirements and tests for metallic connection components that form part of a lightning protection system (LPS). Typically, these can be connectors, clamps, bonding and bridging components, expansion pieces and test joints.\r\nFor the purposes of this document the following connection types are considered as connection components: exothermic, brazing, welding, clamping, crimping, seaming, screwing or bolting. Testing of components for an explosive atmosphere is not covered by this document.\r\nThis second edition cancels and replaces the first edition, published in 2012. This edition constitutes a technical revision.\r\nThis edition includes the following significant technical changes with respect to the previous edition:\r\na. classification of connection components in permanent and non-permanent connection;\r\nb. requirements and corresponding tests for permanent connection components such as exothermic, brazing, welding, crimping, seaming;\r\nc. flow chart of tests for connection components.","protected":false},"featured_media":841,"parent":0,"menu_order":157,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-840","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"Low-voltage surge protective devices\u2013Part11: Surge protective devices connected to low-voltage power systems\u2013Requirements and test methods","txt":"<strong>IEC\/EN 61643-11:2011\u00a0<\/strong>\r\n<strong>Low-voltage surge protective devices\u2013Part11: Surge protective devices connected to low-voltage power systems\u2013Requirements and test methods<\/strong>\r\n\r\nIEC 61643-11:2011 is applicable to devices for surge protection against indirect and direct effects of lightning or other transient overvoltages. These devices are packaged to be connected to 50\/60 Hz a.c. power circuits, and equipment rated up to 1 000 V r.m.s. Performance characteristics, standard methods for testing and ratings are established. These devices contain at least one nonlinear component and are intended to limit surge voltages and divert surge currents. This first edition of IEC 61643-11 cancels and replaces the second edition of IEC 61643-1 published in 2005. The main changes with respect of the second edition of IEC 61643-1 are the complete restructuring and improvement of the test procedures and test sequences.\r\n\r\n<strong>IEC 61643-21:2000\/AMD2:2012\u00a0<\/strong>\r\n<strong>Low voltage surge protective devices \u2013 Part 21: Surge protective devices connected to telecommunications and signalling networks \u2013 Performance requirements and testing methods<\/strong>\r\n\r\n<strong>IEC 61643-12:2020\u00a0<\/strong>\r\n<strong>Low-voltage surge protective devices \u2013 Part 12: Surge protective devices connected to low-voltage power systems \u2013 Selection and application principles<\/strong>\r\n\r\nIEC 61643-12:2020 describes the principles for the selection, operation, location and coordination of SPDs to be connected to 50\/60 Hz AC power circuits, and equipment rated up to 1 000 V RMS. These devices contain at least one non-linear component and are intended to limit surge voltages and divert surge currents.\r\nNOTE 1 Additional requirements for special applications are also applicable, If required.\r\nNOTE 2 IEC 60364 and IEC 62305-4 are also applicable.\r\nNOTE 3 This standard deal only with SPDs and not with surge protection components\r\n\r\n<strong>IEC 61643-22:2015\u00a0<\/strong>\r\n<strong>Low-voltage surge protective devices \u2013 Part 22: Surge protective devices connected to telecommunications and signalling networks \u2013 Selection and application principles<\/strong>\r\n\r\nIEC 61643-22:2015 describes the principles for the selection, operation, location and coordination of SPDs connected to telecommunication and signalling networks with nominal system voltages up to 1 000 V r.m.s. a.c. and 1 500 V d.c. This standard also addresses SPDs that incorporate protection for signalling lines and power lines in the same enclosure (so called multiservice SPDs). This second edition cancels and replaces the first edition published in 2004. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:\r\n\u2013 Update the use of multiservice SPDs (Article 8);\r\n\u2013 Comparison between SPD classification of IEC 61643-11 and IEC 61643-21 (7.3.3);\r\n\u2013 Consideration of new transmission systems as PoE (Annex F);\r\n\u2013 EMC requirements of SPDs (Annex G);\r\n\u2013 Maintenance cycles of SPDs (Annex I). Keywords: SPD, surge protective devices\r\n\r\n<strong>IEC 61643-31:2018\u00a0<\/strong>\r\n<strong>Low-voltage surge protective devices \u2013 Part 31: Requirements and test methods for SPDs for photovoltaic installations<\/strong>\r\n\r\nIEC 61643-31:2018 is applicable to Surge Protective Devices (SPDs), intended for surge protection against indirect and direct effects of lightning or other transient overvoltages. These devices are designed to be connected to the DC side of photovoltaic installations rated up to 1 500 V DC. These devices contain at least one non-linear component and are intended to limit surge voltages and divert surge currents. Performance characteristics, safety requirements, standard methods for testing and ratings are established.\u00a0 SPDs complying with this standard are exclusively dedicated to be installed on the DC side of photovoltaic generators and the DC side of inverters. SPDs for PV systems with energy storage (e.g. batteries, capacitor banks) are not covered. SPDs with separate input and output terminals that contain specific series impedance between these terminal(s) (so called two-port SPDs according to IEC 61643-11:2011) are not covered. SPDs compliant with this standard are designed to be permanently connected where connection and disconnection of fixed SPDs can only be done using a tool. This standard does not apply to portable SPDs.\r\n\r\n<strong>IEC 61643-32:2017\u00a0<\/strong>\r\n<strong>Low-voltage surge protective devices \u2013 Part 32: Surge protective devices connected to the d.c. side of photovoltaic installations \u2013 Selection and application principles<\/strong>\r\n\r\nIEC 61643-32:2017 describes the principles for selection, installation and coordination of SPDs intended for use in Photovoltaic (PV) systems up to 1 500 V DC and for the AC side of the PV system rated up to 1 000 V rms 50\/60 Hz. The photovoltaic installation extends from a PV array or a set of interconnected PV-modules to include the associated cabling and protective devices and the inverter up to the connection point in the distribution board or the utility supply point. This part of IEC 61643 considers SPDs used in different locations and in different kinds of PV systems:PV systems located on the top of a building. PV systems located on the ground like free field power plants characterized by multiple earthing and a meshed earthing system. The term PV installation is used to refer to both kinds of PV systems. The term PV power plant is only used for extended free-field multi-earthed power systems located on the ground. For PV installations including batteries additional requirements may be necessary.\r\n\r\n<strong>IEC 62561-1:2017 RLV\u00a0<\/strong>\r\n<strong>Redline version<\/strong>\r\n<strong>Lightning protection system components (LPSC) \u2013 Part 1: Requirements for connection components<\/strong>\r\n\r\nIEC 62561-1:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is not an official document, it is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.\r\n\r\nIEC 62561-1:2017 specifies the requirements and tests for metallic connection components that form part of a lightning protection system (LPS). Typically, these can be connectors, clamps, bonding and bridging components, expansion pieces and test joints.\r\nFor the purposes of this document the following connection types are considered as connection components: exothermic, brazing, welding, clamping, crimping, seaming, screwing or bolting. Testing of components for an explosive atmosphere is not covered by this document.\r\nThis second edition cancels and replaces the first edition, published in 2012. This edition constitutes a technical revision.\r\nThis edition includes the following significant technical changes with respect to the previous edition:\r\na. classification of connection components in permanent and non-permanent connection;\r\nb. requirements and corresponding tests for permanent connection components such as exothermic, brazing, welding, crimping, seaming;\r\nc. flow chart of tests for connection components."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/blog\/840","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/media\/841"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/media?parent=840"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/blog_category?post=840"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}