{"id":799,"date":"2023-12-19T16:33:42","date_gmt":"2023-12-19T08:33:42","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=799"},"modified":"2024-09-05T16:36:48","modified_gmt":"2024-09-05T08:36:48","slug":"799-2","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/pt\/blog\/799-2\/","title":{"rendered":"Prote\u00e7\u00e3o contra surtos: o que deve ser observado?"},"content":{"rendered":"A prote\u00e7\u00e3o eficaz contra surtos n\u00e3o \u00e9 simplesmente instalada. Tem que ser coordenado individualmente \u2013 ao sistema que deve ser protegido e \u00e0s condi\u00e7\u00f5es ambientais predominantes no local. Por esta raz\u00e3o, o design e o conceito devem ser consistentes. Isto significa que muitos detalhes devem ser levados em considera\u00e7\u00e3o, desde a considera\u00e7\u00e3o das normas e estipula\u00e7\u00f5es at\u00e9 a classifica\u00e7\u00e3o de acordo com a zona de prote\u00e7\u00e3o contra raios.\r\n\r\n<strong>Padr\u00f5es de prote\u00e7\u00e3o contra raios e surtos<\/strong>\r\n\r\nAs normas nacionais e internacionais fornecem um guia para estabelecer um conceito de prote\u00e7\u00e3o contra raios e sobretens\u00f5es, bem como o design dos dispositivos de prote\u00e7\u00e3o individuais.\r\n\r\n<strong>Prote\u00e7\u00e3o contra raios de acordo com IEC 62305<\/strong><strong>:<\/strong>\r\n\r\nPart 1: Characteristics of lightning strikes\r\n\r\nIn Part 1 of this standard [1], the characteristic properties of lightning strikes, the likelihood of occurrence, and the potential for hazard are taken into account.\r\n\r\nPart 2: Risk analysis\r\n\r\nThe risk analysis according to Part 2 of this standard [2] describes a process with which, first of all, the need for lightning protection for a physical system is analyzed. Various sources of damage, e.g., a direct lightning strike in the building, come into focus, as do the types of damage resulting from this:\r\n\r\n\u2022 Impact on health or loss of life\r\n\r\n\u2022 Loss of technical services for the public\r\n\r\n\u2022 Loss of irreplaceable objects of cultural significance\r\n\r\n\u2022 Financial losses\r\n\r\nThe financial benefits are determined as follows: how does the annual total cost for a lightning protection system compare to the costs of potential damage without a protection system? The cost evaluation is based on the outgoings for the planning, assembly, and maintenance of the lightning protection system.\r\n\r\nParts 3 and 4: Planning aids and specifications\r\n\r\nIf the risk assessment determines that lightning protection is required and cost-effective, then the type and scope of the specific measures for protection can be planned based on Parts 3 [3] and 4 [4] of this standard. The lightning protection level determined by risk management is decisive for determining the type and scope of the measures.\r\n\r\nFor physical structures that require an extremely high level of safety, almost all strikes must be captured and conducted away safely. For systems where a higher residual risk is acceptable, strikes with lower amplitudes are not captured.\r\n\r\n<strong>Prote\u00e7\u00e3o contra surtos de acordo com IEC 60364-4-44<\/strong>\r\n\r\nThis standard [5] describes the conditions in which surge protective devices are to be used in low-voltage systems to protect the electrical installation against surge voltages. The area of application is thereby limited to surge voltages caused by atmospheric influences or as a consequence of switching procedures that are transmitted by the power supply system. Direct lightning strikes in a structural system are not considered, only strikes in or in the vicinity of supply lines.\r\n\r\nLikewise, structural systems with an explosion risk as well as structural applications that could cause damage to the environment (e.g., petrochemical systems or nuclear power plants) are not included in the application of the standard. For these processes, lightning strike standard IEC 62305 is to be used exclusively.\r\n\r\nSurge protective devices should be used if transient overvoltage could have effects on the following:\r\n\r\n\u2022 Human lives, e.g., safety systems, hospitals\r\n\r\n\u2022 Public and cultural institutions, e.g., loss of public services, IT centers, museums\r\n\r\n\u2022 Industrial or business activities, e.g., hotels, banks, production systems, farms.\r\n\r\n<strong>Medidas e equipamentos b\u00e1sicos de prote\u00e7\u00e3o<\/strong>\r\n\r\nIn order to consistently protect a structural system from lightning strikes and surge voltages, various protective measures or equipment that are tailored to one another are required. A broad division can be made as follows:\r\n\r\n\u2022 External lightning protection\r\n\r\n\u2022 Internal lightning protection\r\n\r\n\u2022 Grounding and equipotential bonding\r\n\r\n\u2022 Coordinated SPD system\r\n\r\n<strong>Prote\u00e7\u00e3o externa contra raios<\/strong>\r\n\r\nA prote\u00e7\u00e3o externa contra raios (Fig. 15) tem como objetivo desviar os raios que se aproximam do objeto a ser protegido e transmitir a corrente do raio do ponto de impacto para a terra. Como tal, nenhum dano pode ser causado por efeitos t\u00e9rmicos, magn\u00e9ticos ou el\u00e9tricos. A prote\u00e7\u00e3o externa contra raios \u00e9 sistem\u00e1tica: consiste no p\u00e1ra-raios, nos p\u00e1ra-raios e no sistema de aterramento.\r\n\r\n<strong><img class=\"aligncenter\" title=\"10\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/07\/2022082915121199ec989ea1544a65b3dcd6f5dc7aceb0.webp\" alt=\"10\" width=\"300\" height=\"338\" border=\"0\" vspace=\"0\" \/><\/strong>\r\n\r\n<strong>Prote\u00e7\u00e3o interna contra raios<\/strong>\r\n\r\nThe internal lightning protection system should prevent dangerous spark formation inside the system. Sparks can be caused by lightning current in the external lightning protection system or in other conductive parts of the structural system.\r\n\r\nThe internal lightning protection system consists of equipotential bonding and the electrical insulation of external lightning protection systems.\r\n\r\nLightning protection equipotential bonding is a combination of measures that prevent potential differences. They mainly connect the lightning protection system to metal installations, internal systems, as well as electrical and electronic systems within the system.\u00a0This occurs by means of equipotential bonding lines, surge protective devices or isolating spark gaps.\r\n\r\n<strong>Aterramento e liga\u00e7\u00e3o equipotencial<\/strong>\r\n\r\nO sistema de aterramento tem como objetivo distribuir e descarregar para a terra a corrente captada pelo raio. Aqui, o tipo de sistema de aterramento \u00e9 mais importante que a resist\u00eancia de aterramento. A corrente do raio \u00e9 um pulso muito curto que se comporta como uma corrente de alta frequ\u00eancia. Uma liga\u00e7\u00e3o equipotencial eficaz tamb\u00e9m \u00e9 importante. A liga\u00e7\u00e3o equipotencial conecta todas as partes eletricamente condutoras entre si atrav\u00e9s de condutores \u2013 os condutores ativos s\u00e3o protegidos por dispositivos de prote\u00e7\u00e3o contra surtos. Ao fazer isso,protege contra todos os tipos de acoplamentos.\r\n\r\n<strong>Sistema SPD coordenado<\/strong>\r\n\r\nA coordinated SPD system is understood to be a multi-level system of surge protective devices that are coordinated with each other.\r\n\r\nThe following steps are recommended in order to achieve a high-performance SPD system.\r\n\r\n\u2022\u00a0Divide the structural system into lightning protection zones\r\n\r\n\u2022 Incorporate all lines that cross between different zones into the local equipotential bonding using suitable SPDs\r\n\r\n\u2022 Coordinate different types of SPDs: the devices must address each other selectively in order to prevent individual components from overloading\r\n\r\n\u2022 Use short supply lines for the parallel connection of SPDs between active conductors and the equipotential bonding\r\n\r\n\u2022 Lay protected and unprotected lines separately\r\n\r\n\u2022 Only ground equipment via the respective SPD (recommended)\r\n\r\n<strong>Zonas de prote\u00e7\u00e3o contra raios<\/strong>\r\n\r\nDeciding where to install surge protective devices within a structural system is based on the lightning protection zone concept explained in Part 4 of the lightning protection standard IEC 62305 [4].\r\n\r\nIt divides structural systems into lightning protection zones (LPZ), and does so from outside to inside with decreasing lightning protection levels. In external zones only resistant equipment can be used. However, in internal zones, sensitive equipment can also be used. The individual zones are characterized and named as follows:\r\n\r\n<strong>ZLP 0A<\/strong>\r\n\r\nUma \u00e1rea desprotegida fora de um edif\u00edcio onde raios diretos\u00a0s\u00e3o\u00a0uma possibilidade. Acoplamento direto de correntes atmosf\u00e9ricas em linhas, campo magn\u00e9tico n\u00e3o atenuado do raio\r\n\r\n<strong>ZLP 0B<\/strong>\r\n\r\n\u00c1rea externa ao edif\u00edcio protegida da queda direta de raios por meio de um terminal a\u00e9reo. O campo magn\u00e9tico n\u00e3o atenuado do raio apenas induziu correntes de surto nas linhas.\r\n\r\n<strong>ZLP 1<\/strong>\r\n\r\n\u00c1rea dentro do edif\u00edcio que ainda pode estar sujeita a sobretens\u00f5es de alta energia ou correntes de sobretens\u00e3o e fortes campos eletromagn\u00e9ticos\r\n\r\n<strong>ZLP 2<\/strong>\r\n\r\n\u00c1rea dentro de um edif\u00edcio que ainda pode estar sujeita a sobretens\u00f5es ou correntes de sobretens\u00e3o e campos eletromagn\u00e9ticos que j\u00e1 foram significativamente enfraquecidos.\r\n\r\n<strong>ZLP 3<\/strong>\r\n\r\nArea inside the building which may only be subjected to extremely low or hardly any surge voltages or surge currents and very weak or non-existent electromagnetic fields.\r\n\r\nAll lines that cross between zones must use coordinated surge protective devices. Their power values are based on the protection class to be achieved, which is determined according to legal specifications or by means of the risk analysis. When it comes to selecting surge protective devices, use the standard as a basis, assuming that 50% of the lightning current will be discharged to ground. The other 50% of the lightning current is directed to the electrical installation via the main equipotential bonding and from there must be conducted away from the SPD system.","protected":false},"featured_media":800,"parent":0,"menu_order":175,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-799","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"Effective surge protection is not just simply installed. It has to be individually coordinated \u2013 to the system that is to be protected and the ambient conditions that are prevalent on site.","txt":"Effective surge protection is not just simply installed. It has to be individually coordinated \u2013 to the system that is to be protected and the ambient conditions that are prevalent on site. For this reason, the design and concept must be consistent. This means many details must be taken into account, from considering the standards and stipulations right through to classification according to lightning protection zone.\r\n\r\n<strong>Lightning and surge protection standards<\/strong>\r\n\r\nNational and international standards provide a guide to establishing a lightning and surge protection concept as well as the design of the individual protective devices.\r\n\r\n<strong>Lightning protection according to IEC 62305<\/strong><strong>:<\/strong>\r\n\r\nPart 1: Characteristics of lightning strikes\r\n\r\nIn Part 1 of this standard [1], the characteristic properties of lightning strikes, the likelihood of occurrence, and the potential for hazard are taken into account.\r\n\r\nPart 2: Risk analysis\r\n\r\nThe risk analysis according to Part 2 of this standard [2] describes a process with which, first of all, the need for lightning protection for a physical system is analyzed. Various sources of damage, e.g., a direct lightning strike in the building, come into focus, as do the types of damage resulting from this:\r\n\r\n\u2022 Impact on health or loss of life\r\n\r\n\u2022 Loss of technical services for the public\r\n\r\n\u2022 Loss of irreplaceable objects of cultural significance\r\n\r\n\u2022 Financial losses\r\n\r\nThe financial benefits are determined as follows: how does the annual total cost for a lightning protection system compare to the costs of potential damage without a protection system? The cost evaluation is based on the outgoings for the planning, assembly, and maintenance of the lightning protection system.\r\n\r\nParts 3 and 4: Planning aids and specifications\r\n\r\nIf the risk assessment determines that lightning protection is required and cost-effective, then the type and scope of the specific measures for protection can be planned based on Parts 3 [3] and 4 [4] of this standard. The lightning protection level determined by risk management is decisive for determining the type and scope of the measures.\r\n\r\nFor physical structures that require an extremely high level of safety, almost all strikes must be captured and conducted away safely. For systems where a higher residual risk is acceptable, strikes with lower amplitudes are not captured.\r\n\r\n<strong>Surge protection according to IEC 60364-4-44<\/strong>\r\n\r\nThis standard [5] describes the conditions in which surge protective devices are to be used in low-voltage systems to protect the electrical installation against surge voltages. The area of application is thereby limited to surge voltages caused by atmospheric influences or as a consequence of switching procedures that are transmitted by the power supply system. Direct lightning strikes in a structural system are not considered, only strikes in or in the vicinity of supply lines.\r\n\r\nLikewise, structural systems with an explosion risk as well as structural applications that could cause damage to the environment (e.g., petrochemical systems or nuclear power plants) are not included in the application of the standard. For these processes, lightning strike standard IEC 62305 is to be used exclusively.\r\n\r\nSurge protective devices should be used if transient overvoltage could have effects on the following:\r\n\r\n\u2022 Human lives, e.g., safety systems, hospitals\r\n\r\n\u2022 Public and cultural institutions, e.g., loss of public services, IT centers, museums\r\n\r\n\u2022 Industrial or business activities, e.g., hotels, banks, production systems, farms.\r\n\r\n<strong>Basic protective measures and equipment<\/strong>\r\n\r\nIn order to consistently protect a structural system from lightning strikes and surge voltages, various protective measures or equipment that are tailored to one another are required. A broad division can be made as follows:\r\n\r\n\u2022 External lightning protection\r\n\r\n\u2022 Internal lightning protection\r\n\r\n\u2022 Grounding and equipotential bonding\r\n\r\n\u2022 Coordinated SPD system\r\n\r\n<strong>External lightning protection<\/strong>\r\n\r\nExternal lightning protection (Fig. 15) aims to divert strikes which come near to the object to be protected and to transmit the lightning current from the point where it hits to ground. As such, no damage can be caused by means of thermal, magnetic or electrical effects. External lightning protection is systematic: it consists of the air-terminal, the arresters, and the grounding system.\r\n\r\n<strong><img class=\"aligncenter\" title=\"10\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/07\/2022082915121199ec989ea1544a65b3dcd6f5dc7aceb0.webp\" alt=\"10\" width=\"300\" height=\"338\" border=\"0\" vspace=\"0\" \/><\/strong>\r\n\r\n<strong>Internal lightning protection<\/strong>\r\n\r\nThe internal lightning protection system should prevent dangerous spark formation inside the system. Sparks can be caused by lightning current in the external lightning protection system or in other conductive parts of the structural system.\r\n\r\nThe internal lightning protection system consists of equipotential bonding and the electrical insulation of external lightning protection systems.\r\n\r\nLightning protection equipotential bonding is a combination of measures that prevent potential differences. They mainly connect the lightning protection system to metal installations, internal systems, as well as electrical and electronic systems within the system.\u00a0This occurs by means of equipotential bonding lines, surge protective devices or isolating spark gaps.\r\n\r\n<strong>Grounding and equipotential bonding<\/strong>\r\n\r\nThe grounding system aims to distribute and discharge the captured lightning current to ground. Here, the type of grounding system is more important than the grounding resistance. The lightning current is a very short pulse that behaves like a high-frequency current. Effective equipotential bonding is also important. Equipotential bonding connects all electrically conductive parts with each other via conductors \u2013 active conductors are protected by surge protective devices. By doing so, it protects against all types of couplings.\r\n\r\n<strong>Coordinated SPD system<\/strong>\r\n\r\nA coordinated SPD system is understood to be a multi-level system of surge protective devices that are coordinated with each other.\r\n\r\nThe following steps are recommended in order to achieve a high-performance SPD system.\r\n\r\n\u2022\u00a0Divide the structural system into lightning protection zones\r\n\r\n\u2022 Incorporate all lines that cross between different zones into the local equipotential bonding using suitable SPDs\r\n\r\n\u2022 Coordinate different types of SPDs: the devices must address each other selectively in order to prevent individual components from overloading\r\n\r\n\u2022 Use short supply lines for the parallel connection of SPDs between active conductors and the equipotential bonding\r\n\r\n\u2022 Lay protected and unprotected lines separately\r\n\r\n\u2022 Only ground equipment via the respective SPD (recommended)\r\n\r\n<strong>Lightning protection zones<\/strong>\r\n\r\nDeciding where to install surge protective devices within a structural system is based on the lightning protection zone concept explained in Part 4 of the lightning protection standard IEC 62305 [4].\r\n\r\nIt divides structural systems into lightning protection zones (LPZ), and does so from outside to inside with decreasing lightning protection levels. In external zones only resistant equipment can be used. However, in internal zones, sensitive equipment can also be used. The individual zones are characterized and named as follows:\r\n\r\n<strong>LPZ 0A<\/strong>\r\n\r\nUnprotected area outside a building in which direct lightning strikes\u00a0is\u00a0a possibility. Direct coupling of lightning currents in lines, unattenuated magnetic field of the lightning strike\r\n\r\n<strong>LPZ 0B<\/strong>\r\n\r\nArea outside the building that is protected from direct lightning strikes by means of an air-terminal. Unattenuated magnetic field of the lightning strike only induced surge currents on lines.\r\n\r\n<strong>LPZ 1<\/strong>\r\n\r\nArea inside the building which may still be subjected to high-energy surge voltages or surge currents and strong electromagnetic fields\r\n\r\n<strong>LPZ 2<\/strong>\r\n\r\nArea inside a building which may still be subjected to surge voltages or surge currents and electromagnetic fields that have already been significantly weakened.\r\n\r\n<strong>LPZ 3<\/strong>\r\n\r\nArea inside the building which may only be subjected to extremely low or hardly any surge voltages or surge currents and very weak or non-existent electromagnetic fields.\r\n\r\nAll lines that cross between zones must use coordinated surge protective devices. Their power values are based on the protection class to be achieved, which is determined according to legal specifications or by means of the risk analysis. When it comes to selecting surge protective devices, use the standard as a basis, assuming that 50% of the lightning current will be discharged to ground. The other 50% of the lightning current is directed to the electrical installation via the main equipotential bonding and from there must be conducted away from the SPD system."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/blog\/799","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/media\/800"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/media?parent=799"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/blog_category?post=799"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}