{"id":2712,"date":"2026-10-10T09:55:37","date_gmt":"2026-10-10T01:55:37","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=2712"},"modified":"2026-10-14T09:17:13","modified_gmt":"2026-10-14T01:17:13","slug":"where-should-type-3-surge-protective-devices-be-installed-in-a-building","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/pt\/blog\/where-should-type-3-surge-protective-devices-be-installed-in-a-building\/","title":{"rendered":"Where Should Type 3 Surge Protective Devices Be Installed In A Building?"},"content":{"rendered":"<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">Type 3 surge protective devices are the final guard in a layered SPD strategy. While <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/pt\/product_category\/type-3-surge-protector\/\" target=\"_blank\" rel=\"noopener\">Type 3 surge protective devices<\/a> sit closest to the equipment they protect, their effectiveness depends on choosing the right building location and following a few installation rules. This guide explains where to install Type 3 SPDs in a building, why distance matters, and how to coordinate them with upstream protection.<\/p>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">Britec Electric manufactures DIN-rail surge protective devices for commercial, industrial and OEM projects. If you are specifying protection for sensitive electronics, the placement of a Type 3 SPD can be as important as the device rating itself.<\/p>\r\n\r\n<h2 style=\"font-size: 26px; color: #212121; margin: 28px 0 14px 0; border-bottom: 2px solid #009292; padding-bottom: 6px;\">Where Type 3 SPDs Fit in the Protection Hierarchy<\/h2>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">A complete building surge protection plan uses three coordinated levels. Each level is sized and located to handle a different source and magnitude of transient overvoltage.<\/p>\r\n\r\n<table style=\"width: 100%; border-collapse: collapse; margin: 18px 0; font-size: 15px; line-height: 1.6; color: #333333;\">\r\n<tbody>\r\n<tr style=\"background: #041e31; color: #ffffff;\">\r\n<th style=\"padding: 10px; border: 1px solid #e3e8ef; text-align: left;\">SPD Type<\/th>\r\n<th style=\"padding: 10px; border: 1px solid #e3e8ef; text-align: left;\">Localiza\u00e7\u00e3o T\u00edpica<\/th>\r\n<th style=\"padding: 10px; border: 1px solid #e3e8ef; text-align: left;\">Main Threat<\/th>\r\n<th style=\"padding: 10px; border: 1px solid #e3e8ef; text-align: left;\">Typical Rating<\/th>\r\n<\/tr>\r\n<tr style=\"background: #ffffff;\">\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Tipo 1<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Main switchboard \/ service entrance<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Direct lightning current<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Class I \/ up to 100 kA+<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f7f9fc;\">\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Tipo 2<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Distribution boards \/ sub-panels<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Switching transients<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Class II \/ 20\u201340 kA<\/td>\r\n<\/tr>\r\n<tr style=\"background: #ffffff;\">\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Tipo 3<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Point of use \/ final outlets<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Residual \/ local transients<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Class III \/ 6\u201320 kA<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">Type 3 SPDs are not designed to absorb a direct lightning strike. Their job is to clamp the residual overvoltage that may pass through a Type 2 SPD, or to suppress transients generated inside the building by motors, VFDs, switchgear and fluorescent ballasts. Install them as close as possible to the sensitive load for the lowest let-through voltage.<\/p>\r\n\r\n<div style=\"background: #009292; padding: 22px 26px; margin: 24px 0; border-radius: 4px;\">\r\n<h3 style=\"color: #ffffff; margin: 0 0 12px 0; font-size: 20px; line-height: 1.4;\">Need a Tailored Type 3 SPD Solution?<\/h3>\r\n<p style=\"color: #ffffff; margin: 0 0 18px 0; line-height: 1.7; font-size: 15px;\">Britec Electric supplies DIN-rail Type 3 surge protective devices for commercial, industrial and OEM projects. Send your system voltage, configuration and quantity for a fast, engineer-backed recommendation.<\/p>\r\n<p style=\"margin: 0;\"><a style=\"display: inline-block; background: #ffffff; color: #009292; padding: 12px 28px; text-decoration: none; border-radius: 3px; font-weight: bold; font-size: 15px;\" href=\"https:\/\/www.britecelectric.com\/pt\/contact-us\/\" target=\"_blank\" rel=\"noopener\">Request a Quote<\/a><\/p>\r\n\r\n<\/div>\r\n<h2 style=\"font-size: 26px; color: #212121; margin: 28px 0 14px 0; border-bottom: 2px solid #009292; padding-bottom: 6px;\">Where to Install Type 3 SPDs Inside a Building<\/h2>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">The guiding rule is simple: install a Type 3 SPD at the point of use, within a short cable run of the equipment that needs protection. Here are the most common and effective building locations.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Server rooms and network racks<\/strong> \u2014 Install a Type 3 SPD on the DIN rail of the rack power distribution unit or inside a small sub-panel in the server room. Keep the connection length from the SPD to the server PSU well under 10 meters. For PoE switches and other rack-mounted gear, place the Type 3 SPD within the same cabinet.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Control panels and PLCs<\/strong> \u2014 Mount the Type 3 SPD inside the same panel as the controller, on the load side of the branch breaker. This stops surge current from travelling through long control wiring before it is clamped.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Medical and laboratory equipment<\/strong> \u2014 Protect diagnostic machines, analyzers and imaging systems with a dedicated Type 3 SPD installed at the equipment terminal strip or at a nearby dedicated outlet.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Office workstations and AV systems<\/strong> \u2014 Point-of-use surge protectors at the desk or conference-room outlet can act as Type 3 protection. For permanent installations, a DIN-rail Type 3 SPD behind the outlet gives cleaner wiring and better earthing.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Industrial sensors and instrumentation<\/strong> \u2014 Install Type 3 SPDs at the sensor power feed entry point, especially where cables run between buildings, along metal trays or near VFDs.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>LED drivers and emergency lighting<\/strong> \u2014 Protect LED drivers by mounting a Type 3 SPD directly adjacent to the driver terminal block. Britec offers <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/pt\/product_category\/type-3-surge-protector\/\" target=\"_blank\" rel=\"noopener\">10 kA and 20 kA Type 3 surge protectors<\/a> sized for LED street and tunnel lighting loads.<\/p>\r\n\r\n<h2 style=\"font-size: 26px; color: #212121; margin: 28px 0 14px 0; border-bottom: 2px solid #009292; padding-bottom: 6px;\">Wiring and Distance Rules for Type 3 SPDs<\/h2>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">A Type 3 SPD can only protect equipment if the connecting leads are short and the voltage protection level (Up) is low enough. Follow these rules from IEC 60364-5-53 and manufacturer best practice.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Keep lead length short<\/strong> \u2014 Install the SPD as close to the protected load as possible. Effective protection distance is typically considered to be less than 10 meters; beyond that, lead inductance can raise the voltage at the equipment terminals.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Bundle the conductors<\/strong> \u2014 Route the phase, neutral and protective conductors together and keep them straight. Separated or long loops increase the inductive voltage drop during a surge.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Use a common PE reference<\/strong> \u2014 Connect the SPD and the protected load to the same local protective conductor. Do not rely on a remote ground bar at a different potential.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Coordinate with upstream protection<\/strong> \u2014 The Type 3 SPD should have a lower Up than the upstream Type 2 SPD so that it clamps first at the point of use. If Up is higher, the Type 3 SPD may not operate before damage occurs.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Add a backup breaker when specified<\/strong> \u2014 Use a dedicated breaker or fuse for the SPD where the installation standard or manufacturer requires it. This also makes replacement easier at end of life.<\/p>\r\n\r\n<div style=\"background: #009292; padding: 22px 26px; margin: 24px 0; border-radius: 4px;\">\r\n<h3 style=\"color: #ffffff; margin: 0 0 12px 0; font-size: 20px; line-height: 1.4;\">Need a Tailored Type 3 SPD Solution?<\/h3>\r\n<p style=\"color: #ffffff; margin: 0 0 18px 0; line-height: 1.7; font-size: 15px;\">Britec Electric supplies DIN-rail Type 3 surge protective devices for commercial, industrial and OEM projects. Send your system voltage, configuration and quantity for a fast, engineer-backed recommendation.<\/p>\r\n<p style=\"margin: 0;\"><a style=\"display: inline-block; background: #ffffff; color: #009292; padding: 12px 28px; text-decoration: none; border-radius: 3px; font-weight: bold; font-size: 15px;\" href=\"https:\/\/www.britecelectric.com\/pt\/contact-us\/\" target=\"_blank\" rel=\"noopener\">Request a Quote<\/a><\/p>\r\n\r\n<\/div>\r\n<h2 style=\"font-size: 26px; color: #212121; margin: 28px 0 14px 0; border-bottom: 2px solid #009292; padding-bottom: 6px;\">Type 3 SPD Products for Building Installations<\/h2>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">Britec Electric supplies compact DIN-rail Type 3 SPDs for final distribution and point-of-use protection. The right model depends on the system configuration (TT, TN-S, TN-C-S), the number of poles and the discharge current required.<\/p>\r\n<p style=\"margin: 0 0 18px 0; text-align: center;\"><a style=\"display: inline-block; text-decoration: none; color: #009292;\" href=\"https:\/\/www.britecelectric.com\/pt\/product\/br-230-type-3-surge-protector\/\" target=\"_blank\" rel=\"noopener\"><img style=\"max-width: 100%; height: auto; border: 1px solid #e3e8ef; display: block; margin: 0 auto 8px auto;\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2026\/10\/britec-br-230-type3.webp\" alt=\"Britec BR-230 Type 3 surge protector for point-of-use protection\" width=\"320\" height=\"320\" \/><span style=\"font-size: 14px; color: #009292; display: block; text-align: center; text-decoration: underline;\">BR-230 Type 3 surge protector<\/span><\/a><\/p>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">BR-230 Type 3 surge protector is a compact 1+NPE unit rated at Uc 275 V~, In 5 kA and Imax 10 kA, with a voltage protection level of 1.5 kV. It is suitable for final circuits protecting PLCs, control systems, office equipment and other sensitive loads.<\/p>\r\n<p style=\"margin: 0 0 18px 0; text-align: center;\"><a style=\"display: inline-block; text-decoration: none; color: #009292;\" href=\"https:\/\/www.britecelectric.com\/pt\/product\/br-20dp-2p-20ka-type-3-surge-protector\/\" target=\"_blank\" rel=\"noopener\"><img style=\"max-width: 100%; height: auto; border: 1px solid #e3e8ef; display: block; margin: 0 auto 8px auto;\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2026\/10\/britec-br-20dp-2p-type3.webp\" alt=\"Britec BR-20DP 2P 20kA Type 3 surge protector\" width=\"320\" height=\"320\" \/><span style=\"font-size: 14px; color: #009292; display: block; text-align: center; text-decoration: underline;\">BR-20DP 2P 20 kA Type 3 SPD<\/span><\/a><\/p>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">For higher-load branch circuits, BR-20DP 2P 20 kA Type 3 SPD provides Class III protection with Imax 20 kA and Up 1.2 kV. The 2-pole configuration fits TN-S and TT systems where a higher discharge capacity is needed close to the load.<\/p>\r\n<p style=\"margin: 0 0 18px 0; text-align: center;\"><a style=\"display: inline-block; text-decoration: none; color: #009292;\" href=\"https:\/\/www.britecelectric.com\/pt\/product\/br-20dp-11-20ka-type-3-surge-protector\/\" target=\"_blank\" rel=\"noopener\"><img style=\"max-width: 100%; height: auto; border: 1px solid #e3e8ef; display: block; margin: 0 auto 8px auto;\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2026\/10\/britec-br-20dp-1plus1-type3.webp\" alt=\"Britec BR-20DP 1+1 20kA Type 3 surge protector for TT and TNS systems\" width=\"320\" height=\"320\" \/><span style=\"font-size: 14px; color: #009292; display: block; text-align: center; text-decoration: underline;\">BR-20DP 1+1 20 kA Type 3 SPD<\/span><\/a><\/p>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">For TT and TNS networks, BR-20DP 1+1 20 kA Type 3 SPD combines line-to-neutral and N-to-PE protection paths. Match the maximum continuous operating voltage (Uc), nominal discharge current (In) and voltage protection level (Up) to the equipment being protected.<\/p>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">For more detail on choosing the correct rating, see our <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/pt\/blog\/type-3-surge-protective-device-selection-guide\/\" target=\"_blank\" rel=\"noopener\">Type 3 SPD selection guide<\/a>.<\/p>\r\n\r\n<h2 style=\"font-size: 26px; color: #212121; margin: 28px 0 14px 0; border-bottom: 2px solid #009292; padding-bottom: 6px;\">Common Installation Mistakes to Avoid<\/h2>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">Even a high-quality Type 3 SPD can fail to protect equipment if it is installed incorrectly. Avoid these common errors.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Mounting the SPD too far from the load<\/strong> \u2014 A Type 3 SPD installed in a central panel with long cable runs to the equipment loses much of its protective value.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Loose or unbundled connection leads<\/strong> \u2014 Long, separated phase and neutral conductors create extra inductance and raise the let-through voltage.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>No upstream Type 2 protection in high-risk sites<\/strong> \u2014 Type 3 SPDs are not substitutes for Type 2 SPDs in commercial or industrial buildings exposed to large transients.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Mismatched Uc values<\/strong> \u2014 The SPD must have a Uc rating equal to or higher than the continuous operating voltage of the circuit.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Ignoring end-of-life indicators<\/strong> \u2014 Most Type 3 SPDs have a status window. If the indicator turns red, replace the unit immediately. Read our guide on <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/pt\/blog\/how-to-know-if-a-type-3-spd-needs-replacement\/\" target=\"_blank\" rel=\"noopener\">how to know if a Type 3 SPD needs replacement<\/a>.<\/p>\r\n\r\n<h2 style=\"font-size: 26px; color: #212121; margin: 28px 0 14px 0; border-bottom: 2px solid #009292; padding-bottom: 6px;\">Perguntas frequentes<\/h2>\r\n<div style=\"border-left: 3px solid #009292; padding-left: 16px; margin: 18px 0;\">\r\n<p style=\"margin: 0 0 8px 0; line-height: 1.6; color: #212121;\"><strong style=\"color: #009292;\">Q: What is the difference between a Type 2 and a Type 3 surge protective device?<\/strong><\/p>\r\n<p style=\"margin: 0; line-height: 1.8; color: #333333;\">Type 2 SPDs are installed at distribution boards and protect against switching transients from within the building. Type 3 surge protective devices are point-of-use devices installed close to sensitive equipment to clamp residual transients. They are coordinated, not interchangeable.<\/p>\r\n\r\n<\/div>\r\n<div style=\"border-left: 3px solid #009292; padding-left: 16px; margin: 18px 0;\">\r\n<p style=\"margin: 0 0 8px 0; line-height: 1.6; color: #212121;\"><strong style=\"color: #009292;\">Q: How far can a Type 3 SPD be installed from the equipment?<\/strong><\/p>\r\n<p style=\"margin: 0; line-height: 1.8; color: #333333;\">Keep the connecting cable as short as possible. IEC 60364-5-53 guidance treats the effective protection distance as limited to roughly 10 meters. Beyond that, lead inductance can raise the voltage at the equipment terminals.<\/p>\r\n\r\n<\/div>\r\n<div style=\"border-left: 3px solid #009292; padding-left: 16px; margin: 18px 0;\">\r\n<p style=\"margin: 0 0 8px 0; line-height: 1.6; color: #212121;\"><strong style=\"color: #009292;\">Q: Can I use a Type 3 SPD without a Type 2 SPD?<\/strong><\/p>\r\n<p style=\"margin: 0; line-height: 1.8; color: #333333;\">In a low-risk domestic or small-office environment a Type 3 SPD at the outlet may be enough. In commercial, industrial or lightning-prone buildings a coordinated Type 2 + Type 3 cascade is strongly recommended, because Type 3 SPDs are not designed for direct lightning currents.<\/p>\r\n\r\n<\/div>\r\n<div style=\"border-left: 3px solid #009292; padding-left: 16px; margin: 18px 0;\">\r\n<p style=\"margin: 0 0 8px 0; line-height: 1.6; color: #212121;\"><strong style=\"color: #009292;\">Q: Where is the best place to install a Type 3 SPD in a server room?<\/strong><\/p>\r\n<p style=\"margin: 0; line-height: 1.8; color: #333333;\">Mount it on the DIN rail of the rack power distribution unit or in a small sub-panel inside the server room, within a few meters of the servers. Use a dedicated breaker and keep the PE connection short and direct.<\/p>\r\n\r\n<\/div>\r\n<div style=\"border-left: 3px solid #009292; padding-left: 16px; margin: 18px 0;\">\r\n<p style=\"margin: 0 0 8px 0; line-height: 1.6; color: #212121;\"><strong style=\"color: #009292;\">Q: Should Type 3 SPDs be installed in office buildings?<\/strong><\/p>\r\n<p style=\"margin: 0; line-height: 1.8; color: #333333;\">Yes. Office buildings contain computers, network switches, AV equipment, access control and fire-safety controllers. Installing Type 3 SPDs at the final outlets or equipment terminals adds the final level of protection against internally generated transients.<\/p>\r\n\r\n<\/div>\r\n<div style=\"border-left: 3px solid #009292; padding-left: 16px; margin: 18px 0;\">\r\n<p style=\"margin: 0 0 8px 0; line-height: 1.6; color: #212121;\"><strong style=\"color: #009292;\">Q: Do Type 3 SPDs need a dedicated circuit breaker?<\/strong><\/p>\r\n<p style=\"margin: 0; line-height: 1.8; color: #333333;\">A dedicated breaker or fuse is good practice. It allows safe isolation during maintenance and provides backup overcurrent protection. Size the backup protection according to the SPD manufacturer's recommendation.<\/p>\r\n\r\n<\/div>\r\n<h2 style=\"font-size: 26px; color: #212121; margin: 28px 0 14px 0; border-bottom: 2px solid #009292; padding-bottom: 6px;\">Related Resources<\/h2>\r\n<p style=\"margin: 0 0 10px 0; line-height: 1.8; color: #333333; font-size: 16px;\">Explore more Britec guides on Type 3 SPD selection, maintenance and comparison.<\/p>\r\n<p style=\"margin: 6px 0; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/pt\/blog\/type-3-surge-protective-device-selection-guide\/\" target=\"_blank\" rel=\"noopener\">Type 3 Surge Protective Device Selection Guide<\/a><\/p>\r\n<p style=\"margin: 6px 0; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/pt\/blog\/spd-type-3-vs-surge-protection-power-strip-key-differences-explained\/\" target=\"_blank\" rel=\"noopener\">SPD Type 3 vs Surge Protection Power Strip: Key Differences Explained<\/a><\/p>\r\n<p style=\"margin: 6px 0; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/pt\/blog\/what-happens-without-surge-protection-device-type-3\/\" target=\"_blank\" rel=\"noopener\">What Happens Without Surge Protection Device Type 3?<\/a><\/p>\r\n<p style=\"margin: 6px 0; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/pt\/blog\/how-to-know-if-a-type-3-spd-needs-replacement\/\" target=\"_blank\" rel=\"noopener\">How to Know If a Type 3 SPD Needs Replacement<\/a><\/p>\r\n<p style=\"margin: 6px 0; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/pt\/blog\/what-happens-when-type-3-surge-protection-device-reaches-end-of-life\/\" target=\"_blank\" rel=\"noopener\">What Happens When Type 3 Surge Protection Device Reaches End of Life<\/a><\/p>","protected":false},"featured_media":2317,"parent":0,"menu_order":7,"template":"","meta":{"_acf_changed":false},"blog_category":[9],"class_list":["post-2712","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-industry-news"],"acf":{"des":"Discover the right building locations for Type 3 surge protective devices, from point-of-use sockets to server rooms, plus installation rules and selection tips.","txt":"<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">Type 3 surge protective devices are the final guard in a layered SPD strategy. While <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/product_category\/type-3-surge-protector\/\" target=\"_blank\" rel=\"noopener\">Type 3 surge protective devices<\/a> sit closest to the equipment they protect, their effectiveness depends on choosing the right building location and following a few installation rules. This guide explains where to install Type 3 SPDs in a building, why distance matters, and how to coordinate them with upstream protection.<\/p>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">Britec Electric manufactures DIN-rail surge protective devices for commercial, industrial and OEM projects. If you are specifying protection for sensitive electronics, the placement of a Type 3 SPD can be as important as the device rating itself.<\/p>\r\n\r\n<h2 style=\"font-size: 26px; color: #212121; margin: 28px 0 14px 0; border-bottom: 2px solid #009292; padding-bottom: 6px;\">Where Type 3 SPDs Fit in the Protection Hierarchy<\/h2>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">A complete building surge protection plan uses three coordinated levels. Each level is sized and located to handle a different source and magnitude of transient overvoltage.<\/p>\r\n\r\n<table style=\"width: 100%; border-collapse: collapse; margin: 18px 0; font-size: 15px; line-height: 1.6; color: #333333;\">\r\n<tbody>\r\n<tr style=\"background: #041e31; color: #ffffff;\">\r\n<th style=\"padding: 10px; border: 1px solid #e3e8ef; text-align: left;\">SPD Type<\/th>\r\n<th style=\"padding: 10px; border: 1px solid #e3e8ef; text-align: left;\">Typical Location<\/th>\r\n<th style=\"padding: 10px; border: 1px solid #e3e8ef; text-align: left;\">Main Threat<\/th>\r\n<th style=\"padding: 10px; border: 1px solid #e3e8ef; text-align: left;\">Typical Rating<\/th>\r\n<\/tr>\r\n<tr style=\"background: #ffffff;\">\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Type 1<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Main switchboard \/ service entrance<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Direct lightning current<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Class I \/ up to 100 kA+<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f7f9fc;\">\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Type 2<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Distribution boards \/ sub-panels<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Switching transients<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Class II \/ 20\u201340 kA<\/td>\r\n<\/tr>\r\n<tr style=\"background: #ffffff;\">\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Type 3<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Point of use \/ final outlets<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Residual \/ local transients<\/td>\r\n<td style=\"padding: 10px; border: 1px solid #e3e8ef;\">Class III \/ 6\u201320 kA<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">Type 3 SPDs are not designed to absorb a direct lightning strike. Their job is to clamp the residual overvoltage that may pass through a Type 2 SPD, or to suppress transients generated inside the building by motors, VFDs, switchgear and fluorescent ballasts. Install them as close as possible to the sensitive load for the lowest let-through voltage.<\/p>\r\n\r\n<div style=\"background: #009292; padding: 22px 26px; margin: 24px 0; border-radius: 4px;\">\r\n<h3 style=\"color: #ffffff; margin: 0 0 12px 0; font-size: 20px; line-height: 1.4;\">Need a Tailored Type 3 SPD Solution?<\/h3>\r\n<p style=\"color: #ffffff; margin: 0 0 18px 0; line-height: 1.7; font-size: 15px;\">Britec Electric supplies DIN-rail Type 3 surge protective devices for commercial, industrial and OEM projects. Send your system voltage, configuration and quantity for a fast, engineer-backed recommendation.<\/p>\r\n<p style=\"margin: 0;\"><a style=\"display: inline-block; background: #ffffff; color: #009292; padding: 12px 28px; text-decoration: none; border-radius: 3px; font-weight: bold; font-size: 15px;\" href=\"https:\/\/www.britecelectric.com\/contact-us\/\" target=\"_blank\" rel=\"noopener\">Request a Quote<\/a><\/p>\r\n\r\n<\/div>\r\n<h2 style=\"font-size: 26px; color: #212121; margin: 28px 0 14px 0; border-bottom: 2px solid #009292; padding-bottom: 6px;\">Where to Install Type 3 SPDs Inside a Building<\/h2>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">The guiding rule is simple: install a Type 3 SPD at the point of use, within a short cable run of the equipment that needs protection. Here are the most common and effective building locations.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Server rooms and network racks<\/strong> \u2014 Install a Type 3 SPD on the DIN rail of the rack power distribution unit or inside a small sub-panel in the server room. Keep the connection length from the SPD to the server PSU well under 10 meters. For PoE switches and other rack-mounted gear, place the Type 3 SPD within the same cabinet.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Control panels and PLCs<\/strong> \u2014 Mount the Type 3 SPD inside the same panel as the controller, on the load side of the branch breaker. This stops surge current from travelling through long control wiring before it is clamped.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Medical and laboratory equipment<\/strong> \u2014 Protect diagnostic machines, analyzers and imaging systems with a dedicated Type 3 SPD installed at the equipment terminal strip or at a nearby dedicated outlet.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Office workstations and AV systems<\/strong> \u2014 Point-of-use surge protectors at the desk or conference-room outlet can act as Type 3 protection. For permanent installations, a DIN-rail Type 3 SPD behind the outlet gives cleaner wiring and better earthing.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Industrial sensors and instrumentation<\/strong> \u2014 Install Type 3 SPDs at the sensor power feed entry point, especially where cables run between buildings, along metal trays or near VFDs.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>LED drivers and emergency lighting<\/strong> \u2014 Protect LED drivers by mounting a Type 3 SPD directly adjacent to the driver terminal block. Britec offers <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/product_category\/type-3-surge-protector\/\" target=\"_blank\" rel=\"noopener\">10 kA and 20 kA Type 3 surge protectors<\/a> sized for LED street and tunnel lighting loads.<\/p>\r\n\r\n<h2 style=\"font-size: 26px; color: #212121; margin: 28px 0 14px 0; border-bottom: 2px solid #009292; padding-bottom: 6px;\">Wiring and Distance Rules for Type 3 SPDs<\/h2>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">A Type 3 SPD can only protect equipment if the connecting leads are short and the voltage protection level (Up) is low enough. Follow these rules from IEC 60364-5-53 and manufacturer best practice.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Keep lead length short<\/strong> \u2014 Install the SPD as close to the protected load as possible. Effective protection distance is typically considered to be less than 10 meters; beyond that, lead inductance can raise the voltage at the equipment terminals.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Bundle the conductors<\/strong> \u2014 Route the phase, neutral and protective conductors together and keep them straight. Separated or long loops increase the inductive voltage drop during a surge.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Use a common PE reference<\/strong> \u2014 Connect the SPD and the protected load to the same local protective conductor. Do not rely on a remote ground bar at a different potential.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Coordinate with upstream protection<\/strong> \u2014 The Type 3 SPD should have a lower Up than the upstream Type 2 SPD so that it clamps first at the point of use. If Up is higher, the Type 3 SPD may not operate before damage occurs.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Add a backup breaker when specified<\/strong> \u2014 Use a dedicated breaker or fuse for the SPD where the installation standard or manufacturer requires it. This also makes replacement easier at end of life.<\/p>\r\n\r\n<div style=\"background: #009292; padding: 22px 26px; margin: 24px 0; border-radius: 4px;\">\r\n<h3 style=\"color: #ffffff; margin: 0 0 12px 0; font-size: 20px; line-height: 1.4;\">Need a Tailored Type 3 SPD Solution?<\/h3>\r\n<p style=\"color: #ffffff; margin: 0 0 18px 0; line-height: 1.7; font-size: 15px;\">Britec Electric supplies DIN-rail Type 3 surge protective devices for commercial, industrial and OEM projects. Send your system voltage, configuration and quantity for a fast, engineer-backed recommendation.<\/p>\r\n<p style=\"margin: 0;\"><a style=\"display: inline-block; background: #ffffff; color: #009292; padding: 12px 28px; text-decoration: none; border-radius: 3px; font-weight: bold; font-size: 15px;\" href=\"https:\/\/www.britecelectric.com\/contact-us\/\" target=\"_blank\" rel=\"noopener\">Request a Quote<\/a><\/p>\r\n\r\n<\/div>\r\n<h2 style=\"font-size: 26px; color: #212121; margin: 28px 0 14px 0; border-bottom: 2px solid #009292; padding-bottom: 6px;\">Type 3 SPD Products for Building Installations<\/h2>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">Britec Electric supplies compact DIN-rail Type 3 SPDs for final distribution and point-of-use protection. The right model depends on the system configuration (TT, TN-S, TN-C-S), the number of poles and the discharge current required.<\/p>\r\n<p style=\"margin: 0 0 18px 0; text-align: center;\"><a style=\"display: inline-block; text-decoration: none; color: #009292;\" href=\"https:\/\/www.britecelectric.com\/product\/br-230-type-3-surge-protector\/\" target=\"_blank\" rel=\"noopener\"><img style=\"max-width: 100%; height: auto; border: 1px solid #e3e8ef; display: block; margin: 0 auto 8px auto;\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2026\/10\/britec-br-230-type3.webp\" alt=\"Britec BR-230 Type 3 surge protector for point-of-use protection\" width=\"320\" height=\"320\" \/><span style=\"font-size: 14px; color: #009292; display: block; text-align: center; text-decoration: underline;\">BR-230 Type 3 surge protector<\/span><\/a><\/p>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">BR-230 Type 3 surge protector is a compact 1+NPE unit rated at Uc 275 V~, In 5 kA and Imax 10 kA, with a voltage protection level of 1.5 kV. It is suitable for final circuits protecting PLCs, control systems, office equipment and other sensitive loads.<\/p>\r\n<p style=\"margin: 0 0 18px 0; text-align: center;\"><a style=\"display: inline-block; text-decoration: none; color: #009292;\" href=\"https:\/\/www.britecelectric.com\/product\/br-20dp-2p-20ka-type-3-surge-protector\/\" target=\"_blank\" rel=\"noopener\"><img style=\"max-width: 100%; height: auto; border: 1px solid #e3e8ef; display: block; margin: 0 auto 8px auto;\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2026\/10\/britec-br-20dp-2p-type3.webp\" alt=\"Britec BR-20DP 2P 20kA Type 3 surge protector\" width=\"320\" height=\"320\" \/><span style=\"font-size: 14px; color: #009292; display: block; text-align: center; text-decoration: underline;\">BR-20DP 2P 20 kA Type 3 SPD<\/span><\/a><\/p>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">For higher-load branch circuits, BR-20DP 2P 20 kA Type 3 SPD provides Class III protection with Imax 20 kA and Up 1.2 kV. The 2-pole configuration fits TN-S and TT systems where a higher discharge capacity is needed close to the load.<\/p>\r\n<p style=\"margin: 0 0 18px 0; text-align: center;\"><a style=\"display: inline-block; text-decoration: none; color: #009292;\" href=\"https:\/\/www.britecelectric.com\/product\/br-20dp-11-20ka-type-3-surge-protector\/\" target=\"_blank\" rel=\"noopener\"><img style=\"max-width: 100%; height: auto; border: 1px solid #e3e8ef; display: block; margin: 0 auto 8px auto;\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2026\/10\/britec-br-20dp-1plus1-type3.webp\" alt=\"Britec BR-20DP 1+1 20kA Type 3 surge protector for TT and TNS systems\" width=\"320\" height=\"320\" \/><span style=\"font-size: 14px; color: #009292; display: block; text-align: center; text-decoration: underline;\">BR-20DP 1+1 20 kA Type 3 SPD<\/span><\/a><\/p>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">For TT and TNS networks, BR-20DP 1+1 20 kA Type 3 SPD combines line-to-neutral and N-to-PE protection paths. Match the maximum continuous operating voltage (Uc), nominal discharge current (In) and voltage protection level (Up) to the equipment being protected.<\/p>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">For more detail on choosing the correct rating, see our <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/blog\/type-3-surge-protective-device-selection-guide\/\" target=\"_blank\" rel=\"noopener\">Type 3 SPD selection guide<\/a>.<\/p>\r\n\r\n<h2 style=\"font-size: 26px; color: #212121; margin: 28px 0 14px 0; border-bottom: 2px solid #009292; padding-bottom: 6px;\">Common Installation Mistakes to Avoid<\/h2>\r\n<p style=\"margin: 0 0 18px 0; line-height: 1.8; color: #333333; font-size: 16px;\">Even a high-quality Type 3 SPD can fail to protect equipment if it is installed incorrectly. Avoid these common errors.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Mounting the SPD too far from the load<\/strong> \u2014 A Type 3 SPD installed in a central panel with long cable runs to the equipment loses much of its protective value.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Loose or unbundled connection leads<\/strong> \u2014 Long, separated phase and neutral conductors create extra inductance and raise the let-through voltage.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>No upstream Type 2 protection in high-risk sites<\/strong> \u2014 Type 3 SPDs are not substitutes for Type 2 SPDs in commercial or industrial buildings exposed to large transients.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Mismatched Uc values<\/strong> \u2014 The SPD must have a Uc rating equal to or higher than the continuous operating voltage of the circuit.<\/p>\r\n<p style=\"margin: 6px 0 10px; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <strong>Ignoring end-of-life indicators<\/strong> \u2014 Most Type 3 SPDs have a status window. If the indicator turns red, replace the unit immediately. Read our guide on <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/blog\/how-to-know-if-a-type-3-spd-needs-replacement\/\" target=\"_blank\" rel=\"noopener\">how to know if a Type 3 SPD needs replacement<\/a>.<\/p>\r\n\r\n<h2 style=\"font-size: 26px; color: #212121; margin: 28px 0 14px 0; border-bottom: 2px solid #009292; padding-bottom: 6px;\">Frequently Asked Questions<\/h2>\r\n<div style=\"border-left: 3px solid #009292; padding-left: 16px; margin: 18px 0;\">\r\n<p style=\"margin: 0 0 8px 0; line-height: 1.6; color: #212121;\"><strong style=\"color: #009292;\">Q: What is the difference between a Type 2 and a Type 3 surge protective device?<\/strong><\/p>\r\n<p style=\"margin: 0; line-height: 1.8; color: #333333;\">Type 2 SPDs are installed at distribution boards and protect against switching transients from within the building. Type 3 surge protective devices are point-of-use devices installed close to sensitive equipment to clamp residual transients. They are coordinated, not interchangeable.<\/p>\r\n\r\n<\/div>\r\n<div style=\"border-left: 3px solid #009292; padding-left: 16px; margin: 18px 0;\">\r\n<p style=\"margin: 0 0 8px 0; line-height: 1.6; color: #212121;\"><strong style=\"color: #009292;\">Q: How far can a Type 3 SPD be installed from the equipment?<\/strong><\/p>\r\n<p style=\"margin: 0; line-height: 1.8; color: #333333;\">Keep the connecting cable as short as possible. IEC 60364-5-53 guidance treats the effective protection distance as limited to roughly 10 meters. Beyond that, lead inductance can raise the voltage at the equipment terminals.<\/p>\r\n\r\n<\/div>\r\n<div style=\"border-left: 3px solid #009292; padding-left: 16px; margin: 18px 0;\">\r\n<p style=\"margin: 0 0 8px 0; line-height: 1.6; color: #212121;\"><strong style=\"color: #009292;\">Q: Can I use a Type 3 SPD without a Type 2 SPD?<\/strong><\/p>\r\n<p style=\"margin: 0; line-height: 1.8; color: #333333;\">In a low-risk domestic or small-office environment a Type 3 SPD at the outlet may be enough. In commercial, industrial or lightning-prone buildings a coordinated Type 2 + Type 3 cascade is strongly recommended, because Type 3 SPDs are not designed for direct lightning currents.<\/p>\r\n\r\n<\/div>\r\n<div style=\"border-left: 3px solid #009292; padding-left: 16px; margin: 18px 0;\">\r\n<p style=\"margin: 0 0 8px 0; line-height: 1.6; color: #212121;\"><strong style=\"color: #009292;\">Q: Where is the best place to install a Type 3 SPD in a server room?<\/strong><\/p>\r\n<p style=\"margin: 0; line-height: 1.8; color: #333333;\">Mount it on the DIN rail of the rack power distribution unit or in a small sub-panel inside the server room, within a few meters of the servers. Use a dedicated breaker and keep the PE connection short and direct.<\/p>\r\n\r\n<\/div>\r\n<div style=\"border-left: 3px solid #009292; padding-left: 16px; margin: 18px 0;\">\r\n<p style=\"margin: 0 0 8px 0; line-height: 1.6; color: #212121;\"><strong style=\"color: #009292;\">Q: Should Type 3 SPDs be installed in office buildings?<\/strong><\/p>\r\n<p style=\"margin: 0; line-height: 1.8; color: #333333;\">Yes. Office buildings contain computers, network switches, AV equipment, access control and fire-safety controllers. Installing Type 3 SPDs at the final outlets or equipment terminals adds the final level of protection against internally generated transients.<\/p>\r\n\r\n<\/div>\r\n<div style=\"border-left: 3px solid #009292; padding-left: 16px; margin: 18px 0;\">\r\n<p style=\"margin: 0 0 8px 0; line-height: 1.6; color: #212121;\"><strong style=\"color: #009292;\">Q: Do Type 3 SPDs need a dedicated circuit breaker?<\/strong><\/p>\r\n<p style=\"margin: 0; line-height: 1.8; color: #333333;\">A dedicated breaker or fuse is good practice. It allows safe isolation during maintenance and provides backup overcurrent protection. Size the backup protection according to the SPD manufacturer's recommendation.<\/p>\r\n\r\n<\/div>\r\n<h2 style=\"font-size: 26px; color: #212121; margin: 28px 0 14px 0; border-bottom: 2px solid #009292; padding-bottom: 6px;\">Related Resources<\/h2>\r\n<p style=\"margin: 0 0 10px 0; line-height: 1.8; color: #333333; font-size: 16px;\">Explore more Britec guides on Type 3 SPD selection, maintenance and comparison.<\/p>\r\n<p style=\"margin: 6px 0; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/blog\/type-3-surge-protective-device-selection-guide\/\" target=\"_blank\" rel=\"noopener\">Type 3 Surge Protective Device Selection Guide<\/a><\/p>\r\n<p style=\"margin: 6px 0; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/blog\/spd-type-3-vs-surge-protection-power-strip-key-differences-explained\/\" target=\"_blank\" rel=\"noopener\">SPD Type 3 vs Surge Protection Power Strip: Key Differences Explained<\/a><\/p>\r\n<p style=\"margin: 6px 0; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/blog\/what-happens-without-surge-protection-device-type-3\/\" target=\"_blank\" rel=\"noopener\">What Happens Without Surge Protection Device Type 3?<\/a><\/p>\r\n<p style=\"margin: 6px 0; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/blog\/how-to-know-if-a-type-3-spd-needs-replacement\/\" target=\"_blank\" rel=\"noopener\">How to Know If a Type 3 SPD Needs Replacement<\/a><\/p>\r\n<p style=\"margin: 6px 0; padding-left: 22px; text-indent: -16px; line-height: 1.8; color: #333333;\">\u25cf <a style=\"color: #009292; text-decoration: underline;\" href=\"https:\/\/www.britecelectric.com\/blog\/what-happens-when-type-3-surge-protection-device-reaches-end-of-life\/\" target=\"_blank\" rel=\"noopener\">What Happens When Type 3 Surge Protection Device Reaches End of Life<\/a><\/p>"},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/blog\/2712","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/media\/2317"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/media?parent=2712"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/pt\/wp-json\/wp\/v2\/blog_category?post=2712"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}