{"id":983,"date":"2024-09-04T14:10:56","date_gmt":"2024-09-04T06:10:56","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=product&#038;p=983"},"modified":"2025-07-16T16:02:40","modified_gmt":"2025-07-16T08:02:40","slug":"br-25grs-31-type-1-25ka-surge-arrester-for-tt-and-tns","status":"publish","type":"product","link":"https:\/\/www.britecelectric.com\/pl\/product\/br-25gs-31-type-1-2-25ka-surge-arrester-for-tt-and-tns\/","title":{"rendered":"BR-25GS 3P+N Typ 1+2 25kA Ogranicznik przepi\u0119\u0107 dla TT i TNS"},"content":{"rendered":"<h3>Opis<\/h3><p><strong>Charakterystyka produktu:<\/strong><\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td height=\"32\"><strong>Specyfikacja<\/strong><\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25GS 150 3P+N<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25GS 275 3P+N<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25GS 320 3P+N<\/strong><\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Klasyfikacja SPD zgodnie z EN61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Typ 1 + Typ 2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Typ 1 + Typ 2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Typ 1 + Typ 2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Klasyfikacja SPD zgodnie z IEC61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasa I + Klasa II<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasa I + Klasa II<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasa I + Klasa II<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Nominalna praca AC wolta\u017c<\/td>\n<td style=\"text-align: left;\" height=\"32\">Nie<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">120 V\/240 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">230 V\/400 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">240 V\/415 V (50\/60 Hz)<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Maks. praca ci\u0105g\u0142a AC wolta\u017c<\/td>\n<td style=\"text-align: left;\" height=\"32\">Uc (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">150 V\/255 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">275 V\/255 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">320 V\/255 V (50\/60 Hz)<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Pr\u0105d udarowy piorunowy (10\/350\u03bcs)<\/td>\n<td style=\"text-align: left;\" height=\"32\">Iimp (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/100kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Nominalny pr\u0105d roz\u0142adowania (8\/20\u03bcs)<\/td>\n<td style=\"text-align: left;\" height=\"32\">Wej\u015bcie (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/100kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Maks. pr\u0105d roz\u0142adowania (8\/20\u03bcs)<\/td>\n<td style=\"text-align: left;\" height=\"32\">Imax (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA\/150kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA\/150kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA\/150kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Ilo\u015b\u0107 \u0142adunku elektrycznego (L-N, N-PE)<\/td>\n<td style=\"text-align: left;\" height=\"32\">Q (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5A\/50A<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5A\/50A<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5A\/50A<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Energia w\u0142a\u015bciwa (L-N, N-PE)<\/td>\n<td style=\"text-align: left;\" height=\"32\">Z\/R (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9, 2500 kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9, 2500 kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9, 2500 kJ\/\u03a9<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Poziom ochrony napi\u0119cia<\/td>\n<td style=\"text-align: left;\" height=\"32\">W g\u00f3r\u0119 (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,5 kV\/\u22641,5 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,5 kV\/\u22641,5 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,5 kV\/\u22641,5 kV<\/td>\n<\/tr>\n<tr>\n<td>Maks. bezpiecznik zapasowy<\/td>\n<td><\/td>\n<td style=\"text-align: center;\">200A gG<\/td>\n<td style=\"text-align: center;\">200A gG<\/td>\n<td style=\"text-align: center;\">200A gG<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Warto\u015b\u0107 znamionowa pr\u0105du zwarciowego a.c.<\/td>\n<td style=\"text-align: left;\" height=\"32\">Iskr<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">\u015aledzenie aktualnej zdolno\u015bci ga\u015bniczej a.c.<\/td>\n<td style=\"text-align: left;\" height=\"32\">Ifi (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/100A<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/100A<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/100A<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tymczasowa odporno\u015b\u0107 na przepi\u0119cia TOV<\/td>\n<td style=\"text-align: left;\" height=\"32\">UT (L\u2013N)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">230V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">440V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">580V\/120min.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tymczasowa odporno\u015b\u0107 na przepi\u0119cia TOV<\/td>\n<td style=\"text-align: left;\" height=\"32\">UT (N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1200 V\/200 ms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1200 V\/200 ms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1200 V\/200 ms<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Czas reakcji<\/td>\n<td style=\"text-align: left;\" height=\"32\">tA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100ns<\/td>\n<\/tr>\n<tr>\n<td>Pr\u0105d up\u0142ywowy<\/td>\n<td style=\"text-align: left;\">Ipe<\/td>\n<td style=\"text-align: center;\">&lt;0,1 mA<\/td>\n<td style=\"text-align: center;\">&lt;0,1 mA<\/td>\n<td style=\"text-align: center;\">&lt;0,1 mA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Zakres temperatur pracy<\/td>\n<td style=\"text-align: left;\" height=\"32\">Wt<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-85 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-85 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-85 \u2103<\/td>\n<\/tr>\n<tr>\n<td>Wskazanie stanu pracy\/usterki<\/td>\n<td><\/td>\n<td style=\"text-align: center;\">zielony\/czerwony<\/td>\n<td style=\"text-align: center;\">zielony\/czerwony<\/td>\n<td style=\"text-align: center;\">zielony\/czerwony<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Powierzchnia przekroju (min.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Powierzchnia przekroju (maks.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Do monta\u017cu<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">Szyna DIN 35mm<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Materia\u0142 obudowy<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">Termoplastyczny UL94-V0<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Stopie\u0144 ochrony<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Kod zam\u00f3wienia<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17058<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17071<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17096<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Kod zam\u00f3wienia (ze zdaln\u0105 sygnalizacj\u0105)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17059<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17072<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17097<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">Przyrostki: Dodaj przyrostek \u201cRS\u201d dla wersji zdalnej sygnalizacji ze stykiem bezpotencja\u0142owym. Przyk\u0142ad: BR-25GS 275 3P+N RS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Cechy:<\/strong><\/p>\n<p>Typ:\u00a0Ochronnik przeciwprzepi\u0119ciowy T1+T2<\/p>\n<p>Czas reakcji: \u2264100ns<\/p>\n<p>Oznaczone po\u0142\u0105czenia.<\/p>\n<p>Typ kompozytu: 3P+N.<\/p>\n<p>Monta\u017c: standardowa szyna 35mm.<\/p>\n<p>Zaprojektowane do ochrony instalacji elektrycznych niskiego napi\u0119cia przed przepi\u0119ciami elektrycznymi powodowanymi przez prze\u0142\u0105czanie, uderzenia pioruna i impulsy elektromagnetyczne.<\/p>\n<p>Zgodnie z IEC61643-11.<\/p>\n<p>Urz\u0105dzenie do roz\u0142\u0105czania termicznego.<\/p>\n<p>Z\u0142\u0105cze \u015brubowe.<\/p>\n<div>\n<p><strong>Aplikacja:<\/strong><\/p>\n<p>Chroni instalacje elektryczne przed bezpo\u015brednimi uderzeniami pioruna oraz odprowadza pr\u0105d wsteczny powsta\u0142y w wyniku przedostania si\u0119 pioruna od przewodu uziemiaj\u0105cego do przewod\u00f3w sieciowych.<\/p>\n<p>Urz\u0105dzenie jest przeznaczone do stosowania pomi\u0119dzy Stref\u0105 O i Stref\u0105 1 (zgodnie z definicj\u0105 obszaru ochrony odgromowej IEC 62305-4).<\/p>\n<p>Mo\u017ce by\u0107 stosowany do ochrony tr\u00f3jfazowego systemu zasilania.<\/p>\n<p><strong>Sprawy wymagaj\u0105 uwagi podczas instalacji SPD:<\/strong><\/p>\n<p>Okre\u015bl \u015bcie\u017ck\u0119 pr\u0105du roz\u0142adowania.<\/p>\n<p>Zaznacz przewody powoduj\u0105ce dodatkowy spadek napi\u0119cia na zacisku urz\u0105dzenia.<\/p>\n<p>Oznacz przew\u00f3d PE ka\u017cdego urz\u0105dzenia, aby unikn\u0105\u0107 niepotrzebnych p\u0119tli indukcyjnych.<\/p>\n<p>Pomi\u0119dzy urz\u0105dzeniem a SPD tworzone jest po\u0142\u0105czenie ekwipotencjalne.<\/p>\n<p>Podczas instalacji urz\u0105dzenie nale\u017cy pod\u0142\u0105czy\u0107 zgodnie ze schematem instalacji, gdzie L to linia fazowa, N to linia neutralna, a PE to linia uziemiaj\u0105ca. Nie nale\u017cy b\u0142\u0119dnie pod\u0142\u0105cza\u0107 urz\u0105dzenia.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2065\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GS-31-\u5c3a\u5bf8\u56fe.jpg\" alt=\"\" width=\"1941\" height=\"568\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GS-31-\u5c3a\u5bf8\u56fe.jpg 1941w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GS-31-\u5c3a\u5bf8\u56fe-300x88.jpg 300w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GS-31-\u5c3a\u5bf8\u56fe-1024x300.jpg 1024w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GS-31-\u5c3a\u5bf8\u56fe-768x225.jpg 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GS-31-\u5c3a\u5bf8\u56fe-1536x449.jpg 1536w\" sizes=\"auto, (max-width: 1941px) 100vw, 1941px\" \/><\/p>\n<\/div>","protected":false},"parent":0,"menu_order":109,"template":"","meta":{"_acf_changed":false},"product_category":[21],"class_list":["post-983","product","type-product","status-publish","hentry","product_category-type-1-2-lightning-surge-arrester"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/product\/983","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/types\/product"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/media?parent=983"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/product_category?post=983"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}