{"id":931,"date":"2024-09-04T11:05:07","date_gmt":"2024-09-04T03:05:07","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=product&#038;p=931"},"modified":"2026-03-05T15:29:46","modified_gmt":"2026-03-05T07:29:46","slug":"br-25gr-3p-type-1-25ka-surge-arrester-for-tn-c","status":"publish","type":"product","link":"https:\/\/www.britecelectric.com\/pl\/product\/br-25gr-3p-type-1-25ka-surge-arrester-for-tn-c\/","title":{"rendered":"BR-25GR 3P Typ 1 Ogranicznik przepi\u0119\u0107 25kA dla TN-C"},"content":{"rendered":"<h3>Opis<\/h3><p><strong>Charakterystyka produktu:<\/strong><\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td height=\"32\"><strong>Specyfikacja<\/strong><\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25GR 150 3P<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25GR 275 3P<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25GR 350 3P<\/strong><\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Klasyfikacja SPD zgodnie z EN61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Typ 1 + Typ 2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Typ 1 + Typ 2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Typ 1 + Typ 2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Klasyfikacja SPD zgodnie z IEC61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasa I + Klasa II<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasa I + Klasa II<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasa I + Klasa II<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Nominalne napi\u0119cie robocze<\/td>\n<td height=\"32\">Nie<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">120 V\/240 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">230 V\/400 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">250 V\/440 V (50\/60 Hz)<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Maks. praca ci\u0105g\u0142a AC wolta\u017c<\/td>\n<td height=\"32\">Uc<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">150 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">275 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">350 V (50\/60 Hz)<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Pr\u0105d udarowy piorunowy (10\/350\u03bcs)<\/td>\n<td height=\"32\">Iimp<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Nominalny pr\u0105d roz\u0142adowania (8\/20\u03bcs)<\/td>\n<td height=\"32\">W<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Maks. pr\u0105d roz\u0142adowania (8\/20\u03bcs)<\/td>\n<td height=\"32\">Imaks<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Ilo\u015b\u0107 \u0142adunku elektrycznego<\/td>\n<td height=\"32\">Q<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5As<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5As<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5As<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Konkretna energia<\/td>\n<td height=\"32\">Z\/R<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Poziom ochrony napi\u0119cia<\/td>\n<td height=\"32\">W g\u00f3r\u0119<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22642,0 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22642,0 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22642,0 kV<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Warto\u015b\u0107 znamionowa pr\u0105du zwarciowego a.c.<\/td>\n<td height=\"32\">Iskr<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA rms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA rms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA rms<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Maks. bezpiecznik zapasowy<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">315A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">315A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">315A gG<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tymczasowa odporno\u015b\u0107 na przepi\u0119cia TOV<\/td>\n<td height=\"32\">UT<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">230V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">440V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">580V\/120min.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Czas reakcji<\/td>\n<td height=\"32\">tA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100ns<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Zakres temperatur pracy<\/td>\n<td height=\"32\">Wt<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<\/tr>\n<tr>\n<td>Wskazanie stanu pracy\/usterki<\/td>\n<td><\/td>\n<td style=\"text-align: center;\">zielony\/czerwony<\/td>\n<td style=\"text-align: center;\">zielony\/czerwony<\/td>\n<td style=\"text-align: center;\">zielony\/czerwony<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Powierzchnia przekroju (min.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Powierzchnia przekroju (maks.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Do monta\u017cu<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">Szyna DIN 35mm<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Materia\u0142 obudowy<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">Termoplastyczny UL94-V0<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Stopie\u0144 ochrony<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Kod zam\u00f3wienia<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17122<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17135<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17148<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Kod zam\u00f3wienia (ze zdaln\u0105 sygnalizacj\u0105)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17123<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17136<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17149<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Cechy:<\/strong><\/p>\n<p>Wskazuj\u0105ce okno.<\/p>\n<p>Zaprojektowane zgodnie z norm\u0105 IEC 61643-11.<\/p>\n<p>Urz\u0105dzenie zabezpieczaj\u0105ce, kt\u00f3re zapobiega przedostawaniu si\u0119 przepi\u0119\u0107 piorunowych i przej\u015bciowych przet\u0119\u017ce\u0144 do linii zasilaj\u0105cej, zak\u0142\u00f3caj\u0105c normalne dzia\u0142anie systemu zasilania i urz\u0105dze\u0144 elektrycznych.<\/p>\n<p>Warystor o wysokiej wydajno\u015bci z wyzwalaczem termicznym<\/p>\n<p>Tr\u00f3jfazowy ogranicznik przepi\u0119\u0107 pr\u0105du przemiennego<\/p>\n<p>Klasa ochrony: Typ 1, Klasa I<\/p>\n<p>R\u00f3wnoleg\u0142e urz\u0105dzenie przeciwprzepi\u0119ciowe<\/p>\n<p>Obszar przepi\u0119\u0107 u\u017cywany do ochrony wra\u017cliwych urz\u0105dze\u0144 przed skokami napi\u0119cia.<\/p>\n<p>Z du\u017c\u0105 zdolno\u015bci\u0105 roz\u0142adowania pr\u0105du piorunowego<\/p>\n<p>Pr\u0105d roz\u0142adowania udarowego pojedynczego modu\u0142u osi\u0105ga 25 kA (10\/350)<\/p>\n<p>Ograniczniki typu 1 \u0142\u0105cz\u0105 w jednym urz\u0105dzeniu wysok\u0105 wydajno\u015b\u0107 i \u0142atwo\u015b\u0107 obs\u0142ugi. Ich parametry elektryczne zosta\u0142y przystosowane do najbardziej rygorystycznych wymaga\u0144 stawianych systemom ochrony odgromowej i przeciwprzepi\u0119ciowej.<\/p>\n<p>Imaks.: 100 KA(8\/20)<\/p>\n<p><strong>Aplikacja:<\/strong><\/p>\n<p>\u2022 Ma zastosowanie do ochrony odgromowej sieci elektroenergetycznej na terenach o du\u017cym ryzyku piorunowym (LPZ0B lub z\u0142\u0105cze pomi\u0119dzy LPZ0B i LPZ1).<\/p>\n<p>\u2022\u00a0Nadaje si\u0119 do tr\u00f3jfazowych system\u00f3w zasilania TN-C o cz\u0119stotliwo\u015bci pr\u0105du przemiennego od 50 do 60 Hz<\/p>\n<p>\u2022 U\u017cywany g\u0142\u00f3wnie do ochrony przeciwprzepi\u0119ciowej na poziomie systemu zasilania TN-C (B).<\/p>\n<p>\u2022 Zwykle instalowany w budynku w g\u0142\u00f3wnej szafie rozdzielczej niskiego napi\u0119cia lub g\u0142\u00f3wnym wy\u0142\u0105czniku niskiego napi\u0119cia.<\/p>\n<p><strong>Instalacja:<\/strong><\/p>\n<p>Jest instalowany r\u00f3wnolegle w g\u0142\u00f3wnym panelu wlotowym rozdzielnicy po wej\u015bciu niskiego napi\u0119cia do transformatora, skrzynce rozdzielczej z wej\u015bciem napowietrznym w budynku, zewn\u0119trznej szafie rozdzielczej\/skrzynce rozdzielczej i w innych miejscach.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1877\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GR-3P-\u539f\u7406\u56fe.jpg\" alt=\"\" width=\"1839\" height=\"459\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GR-3P-\u539f\u7406\u56fe.jpg 1839w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GR-3P-\u539f\u7406\u56fe-300x75.jpg 300w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GR-3P-\u539f\u7406\u56fe-1024x256.jpg 1024w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GR-3P-\u539f\u7406\u56fe-768x192.jpg 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GR-3P-\u539f\u7406\u56fe-1536x383.jpg 1536w\" sizes=\"auto, (max-width: 1839px) 100vw, 1839px\" \/><\/p>\n<p>&nbsp;<\/p>","protected":false},"parent":0,"menu_order":80,"template":"","meta":{"_acf_changed":false},"product_category":[20],"class_list":["post-931","product","type-product","status-publish","hentry","product_category-type-1-lightning-surge-protection-device"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/product\/931","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/types\/product"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/media?parent=931"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/product_category?post=931"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}