{"id":923,"date":"2024-09-04T10:59:46","date_gmt":"2024-09-04T02:59:46","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=product&#038;p=923"},"modified":"2026-04-09T16:39:24","modified_gmt":"2026-04-09T08:39:24","slug":"br-25m-11-type-1-25ka-surge-arrester-for-tt-and-tns","status":"publish","type":"product","link":"https:\/\/www.britecelectric.com\/pl\/product\/br-25m-11-type-1-25ka-surge-arrester-for-tt-and-tns\/","title":{"rendered":"BR-25M 1+1 Typ 1 25kA Ogranicznik przepi\u0119\u0107 dla TT i TNS"},"content":{"rendered":"<h3>Opis<\/h3><p><strong>Charakterystyka produktu:<\/strong><\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td height=\"32\"><strong>Specyfikacja<\/strong><\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25M 150 1+1<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25M 275 1+1<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25M 320 1+1<\/strong><\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Klasyfikacja SPD zgodnie z EN61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Wpisz 1 + 2 + 3<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Wpisz 1 + 2 + 3<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Wpisz 1 + 2 + 3<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Klasyfikacja SPD zgodnie z IEC61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasa I + II + III<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasa I + II + III<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasa I + II + III<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Nominalne napi\u0119cie robocze<\/td>\n<td height=\"32\">Nie<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">120 V\/240 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">230 V\/400 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">250 V\/440 V (50\/60 Hz)<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Maks. praca ci\u0105g\u0142a AC wolta\u017c<\/td>\n<td height=\"32\">Uc (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">150 V\/255 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">275 V\/255 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">320 V\/255 V (50\/60 Hz)<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Pr\u0105d udarowy piorunowy (10\/350\u03bcs)<\/td>\n<td height=\"32\">Iimp (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/50kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/50kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/50kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Ca\u0142kowity pr\u0105d roz\u0142adowania (10\/350\u03bcs)<\/td>\n<td height=\"32\">Razem<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">50kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">50kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">50kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Nominalny pr\u0105d roz\u0142adowania (8\/20\u03bcs)<\/td>\n<td height=\"32\">Wej\u015bcie (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/50kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/50kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/50kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Maks. pr\u0105d roz\u0142adowania (8\/20\u03bcs)<\/td>\n<td height=\"32\">Imax (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">120 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">120 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">120 kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Ilo\u015b\u0107 \u0142adunku elektrycznego (L-N, N-PE)<\/td>\n<td height=\"32\">Q<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5As, 25As<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5As, 25As<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5As, 25As<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Energia w\u0142a\u015bciwa (L-N, N-PE)<\/td>\n<td height=\"32\">Z\/R<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9, 625 kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9, 625 kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9, 625 kJ\/\u03a9<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Poziom ochrony napi\u0119cia<\/td>\n<td height=\"32\">W g\u00f3r\u0119 (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22640,8 kV\/\u22641,5 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,3 kV\/\u22641,5 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,3 kV\/\u22641,5 kV<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Warto\u015b\u0107 znamionowa pr\u0105du zwarciowego a.c.<\/td>\n<td height=\"32\">Iscr (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA rms\/100A rms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA rms\/100A rms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA rms\/100A rms<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Maks. bezpiecznik zapasowy<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">200A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">200A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">200A gG<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tymczasowa odporno\u015b\u0107 na przepi\u0119cia TOV<\/td>\n<td height=\"32\">UT(L-N)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">180 V\/5 sek.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">335 V\/5 sek.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">400 V\/5 sek.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tymczasowa awaria przepi\u0119ciowa bezpieczna dla TOV<\/td>\n<td height=\"32\">UT (L\u2013N)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">230V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">440V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">520V\/120min.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tymczasowa odporno\u015b\u0107 na przepi\u0119cia TOV<\/td>\n<td height=\"32\">UT(N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1200 V\/200 ms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1200 V\/200 ms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1200 V\/200 ms<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Pr\u0105d up\u0142ywowy<\/td>\n<td height=\"32\">Ipe<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Nic<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Nic<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Nic<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Czas reakcji<\/td>\n<td height=\"32\">tA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns\/\u2264100ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns\/\u2264100ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns\/\u2264100ns<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Zakres temperatur pracy<\/td>\n<td height=\"32\">Wt<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<\/tr>\n<tr>\n<td>Wskazanie stanu pracy\/usterki<\/td>\n<td><\/td>\n<td style=\"text-align: center;\">zielony\/czerwony<\/td>\n<td style=\"text-align: center;\">zielony\/czerwony<\/td>\n<td style=\"text-align: center;\">zielony\/czerwony<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Powierzchnia przekroju (min.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Powierzchnia przekroju (maks.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Do monta\u017cu<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">Szyna DIN 35mm<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Materia\u0142 obudowy<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">Termoplastyczny UL94-V0<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Stopie\u0144 ochrony<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Kod zam\u00f3wienia<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17210<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18153<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17223<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Kod zam\u00f3wienia (ze zdaln\u0105 sygnalizacj\u0105)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17211<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18154<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17224<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Cechy:<\/strong><\/p>\n<p>Czas reakcji: \u226425ns\/\u2264100ns<\/p>\n<p>Nominalny pr\u0105d roz\u0142adowania (8\/20us): 25kA<\/p>\n<p>Zakres temperatur: -40 \u2103\u201380 \u2103<\/p>\n<p>Ochrona przeciwprzepi\u0119ciowa klasy I+II \/ typu 1+2.<\/p>\n<p>Numer katalogowy: BR-25M 1P+N<\/p>\n<p>Sk\u0142ada si\u0119 z wysokowydajnego warystora z wyzwalaczem termicznym.<\/p>\n<p>Liczba biegun\u00f3w: 1P+N<\/p>\n<p>Dzi\u0119ki wy\u0142\u0105cznikowi automatycznemu kontroli temperatury i wbudowanemu obwodowi zabezpieczaj\u0105cemu przed przet\u0119\u017ceniem, modu\u0142owy SPD mo\u017ce zosta\u0107 automatycznie zwolniony, aby unikn\u0105\u0107 zagro\u017cenia po\u017carowego w przypadku awarii.<\/p>\n<p>Wsparcie OEM<\/p>\n<p>Urz\u0105dzenie przeciwprzepi\u0119ciowe (SPD) jest niezb\u0119dnym urz\u0105dzeniem do ochrony odgromowej sprz\u0119tu elektronicznego.<\/p>\n<p>S\u0142u\u017cy do ograniczenia chwilowego przepi\u0119cia linii energetycznej do zakresu napi\u0119cia, jaki mo\u017ce wytrzyma\u0107 sprz\u0119t lub system, lub do silnego pr\u0105du piorunowego sp\u0142ywaj\u0105cego do ziemi w celu ochrony chronionego sprz\u0119tu lub systemu przed uderzeniami i uszkodzeniami.<\/p>\n<p>Materia\u0142 obudowy: tworzywo termoplastyczne UL94-V0<\/p>\n<div>\n<p><strong>Aplikacja:<\/strong><\/p>\n<p>Stosowany w klasie SPD \u2160 (klasa B) dla r\u00f3\u017cnych system\u00f3w zasilania ochrony przeciwprzepi\u0119ciowej.<\/p>\n<p>SPD zwykle instaluje si\u0119 w skrzynce rozdzielczej budynku, centrum komputerowym, pomieszczeniu telekomunikacyjnym, sterowni wind, pomieszczeniu z okablowaniem telewizyjnym, sterowni budynku, centrum monitorowania bezpiecze\u0144stwa, centrum kontroli przeciwpo\u017carowej, sterowni przemys\u0142owej, sterowni sprz\u0119tu przetwornicy cz\u0119stotliwo\u015bci, sali operacyjnej szpitala, pomieszczeniu monitorowania i skrzynce rozdzielczej, w kt\u00f3rej znajduj\u0105 si\u0119 elektroniczne urz\u0105dzenia mechaniczne.<\/p>\n<\/div>\n<p>Ochronnik przeciwprzepi\u0119ciowy typu 1 jest zwykle instalowany na styku LPZ0B i LPZ1<\/p>\n<p>Mo\u017cna go zainstalowa\u0107 w szafie rozdzielczej\/skrzynce rozdzielczej niskiego napi\u0119cia w budynku.<\/p>\n<p>Nadaje si\u0119 do szaf rozdzielczych i skrzynek rozdzielczych z zewn\u0119trznymi liniami dost\u0119powymi w budynkach.<\/p>\n<p>Potrafi wytrzyma\u0107 pr\u0105dy piorunowe i chroni\u0107 wra\u017cliwy sprz\u0119t elektroniczny.<\/p>\n<p>Szeroko stosowane w sprz\u0119cie komunikacyjnym, energetyce, bezpiecze\u0144stwie, ruchu, kontroli przemys\u0142owej i innych dziedzinach ochrony zasilania.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1617\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-11-\u539f\u7406\u56fe.jpg\" alt=\"\" width=\"1799\" height=\"451\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-11-\u539f\u7406\u56fe.jpg 1799w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-11-\u539f\u7406\u56fe-300x75.jpg 300w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-11-\u539f\u7406\u56fe-1024x257.jpg 1024w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-11-\u539f\u7406\u56fe-768x193.jpg 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-11-\u539f\u7406\u56fe-1536x385.jpg 1536w\" sizes=\"auto, (max-width: 1799px) 100vw, 1799px\" \/><\/p>\n<p>&nbsp;<\/p>","protected":false},"parent":0,"menu_order":78,"template":"","meta":{"_acf_changed":false},"product_category":[20],"class_list":["post-923","product","type-product","status-publish","hentry","product_category-type-1-lightning-surge-protection-device"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/product\/923","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/types\/product"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/media?parent=923"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/product_category?post=923"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}