{"id":730,"date":"2024-08-28T14:14:32","date_gmt":"2024-08-28T06:14:32","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=product&#038;p=730"},"modified":"2025-12-29T09:40:09","modified_gmt":"2025-12-29T01:40:09","slug":"br-25m-4p-type-1-25ka-surge-arrester-for-tns","status":"publish","type":"product","link":"https:\/\/www.britecelectric.com\/pl\/product\/br-25m-4p-type-1-25ka-surge-arrester-for-tns\/","title":{"rendered":"BR-25M 4P Typ 1 25kA Ogranicznik przepi\u0119\u0107 dla TNS"},"content":{"rendered":"<h3>Opis<\/h3><p><strong>Charakterystyka produktu:<\/strong><\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td height=\"32\"><strong>Specyfikacja<\/strong><\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25M 150 4P<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25M 275 4P<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25M 320 4P<\/strong><\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Klasyfikacja SPD zgodnie z EN61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Typ 1 + Typ 2 + Typ 3<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Typ 1 + Typ 2 + Typ 3<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Typ 1 + Typ 2 + Typ 3<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Klasyfikacja SPD zgodnie z IEC61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasa I + Klasa II + Klasa III<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasa I + Klasa II + Klasa III<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasa I + Klasa II + Klasa III<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Nominalne napi\u0119cie robocze<\/td>\n<td height=\"32\">Nie<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">120 V\/240 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">230 V\/400 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">250 V\/440 V (50\/60 Hz)<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Maks. praca ci\u0105g\u0142a AC wolta\u017c<\/td>\n<td height=\"32\">Uc<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">150 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">275 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">320 V (50\/60 Hz)<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Pr\u0105d udarowy piorunowy (10\/350\u03bcs)<\/td>\n<td height=\"32\">Iimp<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Ca\u0142kowity pr\u0105d roz\u0142adowania (10\/350\u03bcs)<\/td>\n<td height=\"32\">Razem<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Nominalny pr\u0105d roz\u0142adowania (8\/20\u03bcs)<\/td>\n<td height=\"32\">W<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Maks. pr\u0105d roz\u0142adowania (8\/20\u03bcs)<\/td>\n<td height=\"32\">Imaks<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">120 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">120 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">120 kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Ilo\u015b\u0107 \u0142adunku elektrycznego<\/td>\n<td height=\"32\">Q<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5As<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5As<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5As<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Konkretna energia<\/td>\n<td height=\"32\">Z\/R<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Poziom ochrony napi\u0119cia<\/td>\n<td height=\"32\">W g\u00f3r\u0119<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22640,8 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,3 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,3 kV<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Warto\u015b\u0107 znamionowa pr\u0105du zwarciowego a.c.<\/td>\n<td height=\"32\">Iskr<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA rms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA rms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA rms<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Maks. bezpiecznik zapasowy<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">200A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">200A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">200A gG<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tymczasowa odporno\u015b\u0107 na przepi\u0119cia TOV<\/td>\n<td height=\"32\">UT<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">180 V\/5 sek.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">335 V\/5 sek.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">400 V\/5 sek.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tymczasowa awaria przepi\u0119ciowa bezpieczna dla TOV<\/td>\n<td height=\"32\">UT<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">230V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">440V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">520V\/120min.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Pr\u0105d up\u0142ywowy<\/td>\n<td height=\"32\">Ipe<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">&lt;0,5 mA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">&lt;0,5 mA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">&lt;0,5 mA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Czas reakcji<\/td>\n<td height=\"32\">tA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Zakres temperatur pracy<\/td>\n<td height=\"32\">Wt<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<\/tr>\n<tr>\n<td>Wskazanie stanu pracy\/usterki<\/td>\n<td><\/td>\n<td style=\"text-align: center;\">zielony\/czerwony<\/td>\n<td style=\"text-align: center;\">zielony\/czerwony<\/td>\n<td style=\"text-align: center;\">zielony\/czerwony<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Powierzchnia przekroju (min.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Powierzchnia przekroju (maks.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Do monta\u017cu<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">Szyna DIN 35mm<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Materia\u0142 obudowy<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">Termoplastyczny UL94-V0<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Stopie\u0144 ochrony<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Kod zam\u00f3wienia<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17200<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18143<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17213<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Kod zam\u00f3wienia (ze zdaln\u0105 sygnalizacj\u0105)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17201<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18144<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17214<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Cechy:<\/strong><\/p>\n<p>Numer bieguna: 1P,2P,3P,4P,1+1NPE,3+1NPE<\/p>\n<p>Mocne komponenty, odpowiednie do wszystkich rodzaj\u00f3w popularnych system\u00f3w zasilania.<\/p>\n<p>Mo\u017ce by\u0107 stosowany w systemach TN-S<\/p>\n<p>Ogranicznik przepi\u0119\u0107 spe\u0142nia wymagania normy IEC61643-11<\/p>\n<p>Urz\u0105dzenie zosta\u0142o zaprojektowane do u\u017cytku pomi\u0119dzy Stref\u0105 O i Stref\u0105 1 (zgodnie z definicj\u0105 obszaru ochrony odgromowej IEC62305-4).<\/p>\n<p>Produkt stosowany jest g\u0142\u00f3wnie do ochrony klasy I systemu elektroenergetycznego.<\/p>\n<p>Produkt ma g\u0142\u00f3wnie przebieg 10\/350, do 25KA<\/p>\n<p>Zainstalowany w g\u0142\u00f3wnej dystrybucji zasilania<\/p>\n<p><strong>Aplikacja:<\/strong><\/p>\n<p>\u2022 Produkt stosowany g\u0142\u00f3wnie do podstawowego zabezpieczenia systemu elektroenergetycznego.<\/p>\n<p>\u2022 Zoptymalizowany pod k\u0105tem zastosowania i okablowany kombinowany ogranicznik przepi\u0119\u0107 i przepi\u0119\u0107 dla sieci TN-S.<\/p>\n<p>\u2022 Zainstalowany w g\u0142\u00f3wnej skrzynce rozdzielczej zasilania.<\/p>\n<p>\u2022 Stosowany w przemy\u015ble i automatyce, instalacjach komercyjnych i mieszkaniowych, telekomunikacji, IT i centrach danych, uzdatnianiu wody, inteligentnych sieciach i pomiarach niskiego napi\u0119cia, fotowoltaice i elektrowniach wiatrowych itp.<\/p>\n<p><strong>Instalacja:<\/strong><\/p>\n<p>\u2022 Przed instalacj\u0105 nale\u017cy od\u0142\u0105czy\u0107 zasilanie. Praca pod napi\u0119ciem jest zabroniona.<\/p>\n<p>\u2022 Zaleca si\u0119, aby bezpiecznik lub wy\u0142\u0105cznik automatyczny by\u0142 pod\u0142\u0105czony szeregowo na przednim ko\u0144cu zabezpieczenia przeciwprzepi\u0119ciowego.<\/p>\n<p>\u2022 SPD jest instalowany r\u00f3wnolegle na ko\u0144cu wlotu zasilania w skrzynce rozdzielczej budynku lub w pomieszczeniu technicznym. Produkt montowany jest w wersji szynowej. Je\u015bli warunki na to pozwalaj\u0105, mo\u017cna zastosowa\u0107 tryb po\u0142\u0105czenia Kevina.<\/p>\n<p>\u2022 Podczas instalacji urz\u0105dzenie nale\u017cy pod\u0142\u0105czy\u0107 zgodnie ze schematem instalacji, gdzie L to linia fazowa, N to linia neutralna, a PE to linia uziemiaj\u0105ca. Nie nale\u017cy b\u0142\u0119dnie pod\u0142\u0105cza\u0107 urz\u0105dzenia. Po zako\u0144czeniu instalacji w\u0142\u0105cz automatyczny wy\u0142\u0105cznik i sprawd\u017a, czy stan pracy jest normalny.<\/p>\n<p>\u2022 Gdy u\u017cywany jest SPD, regularnie sprawdzaj stan okna wy\u015bwietlania usterek. Je\u015bli okno wy\u015bwietlania usterek jest czerwone lub zdalny terminal wysy\u0142a sygna\u0142 alarmowy, oznacza to, \u017ce SPD jest uszkodzony i nale\u017cy go naprawi\u0107 lub wymieni\u0107 na czas.<\/p>\n<p>\u2022 Nadaje si\u0119 do u\u017cytku w pomieszczeniach, np. instalowany na zewn\u0105trz, musi by\u0107 wyposa\u017cony w wodoodporn\u0105 obudow\u0119.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1602\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/BR-25M-4P-\u539f\u7406\u56fe.jpg\" alt=\"\" width=\"1749\" height=\"451\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/BR-25M-4P-\u539f\u7406\u56fe.jpg 1749w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/BR-25M-4P-\u539f\u7406\u56fe-300x77.jpg 300w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/BR-25M-4P-\u539f\u7406\u56fe-1024x264.jpg 1024w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/BR-25M-4P-\u539f\u7406\u56fe-768x198.jpg 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/BR-25M-4P-\u539f\u7406\u56fe-1536x396.jpg 1536w\" sizes=\"auto, (max-width: 1749px) 100vw, 1749px\" \/><\/p>\n<p>&nbsp;<\/p>","protected":false},"parent":0,"menu_order":1,"template":"","meta":{"_acf_changed":false},"product_category":[20],"class_list":["post-730","product","type-product","status-publish","hentry","product_category-type-1-lightning-surge-protection-device"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/product\/730","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/types\/product"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/media?parent=730"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/product_category?post=730"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}