{"id":1174,"date":"2024-09-04T22:44:53","date_gmt":"2024-09-04T14:44:53","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=product&#038;p=1174"},"modified":"2024-12-25T15:32:46","modified_gmt":"2024-12-25T07:32:46","slug":"br-110-11-type-2-110ka-surge-protective-device-for-tt-and-tns","status":"publish","type":"product","link":"https:\/\/www.britecelectric.com\/pl\/product\/br-110-11-type-2-110ka-surge-protective-device-for-tt-and-tns\/","title":{"rendered":"BR-110 1+1 Typ 2 110kA Urz\u0105dzenie przeciwprzepi\u0119ciowe dla TT i TNS"},"content":{"rendered":"<h3>Opis<\/h3><p><strong>Charakterystyka produktu:<\/strong><\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td height=\"32\"><strong>Specyfikacja<\/strong><\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-110 275 1+1<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-110 320 1+1<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-110 385 1+1<\/strong><\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Klasyfikacja SPD zgodnie z EN61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Typ 2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Typ 2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Typ 2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Klasyfikacja SPD zgodnie z IEC61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasa II<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasa II<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasa II<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Maks. praca ci\u0105g\u0142a AC napi\u0119cie (L-N)<\/td>\n<td height=\"32\">Uc<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">275 V<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">320 V<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">385 V<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Maks. praca ci\u0105g\u0142a AC napi\u0119cie (N-PE)<\/td>\n<td height=\"32\">Uc<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">255 V<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">255 V<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">255 V<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Nominalny pr\u0105d roz\u0142adowania (8\/20\u03bcs)<\/td>\n<td height=\"32\">W<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">50kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">50kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">50kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Maks. pr\u0105d roz\u0142adowania (8\/20\u03bcs)<\/td>\n<td height=\"32\">Imaks<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">110kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">110kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">110kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Poziom ochrony napi\u0119cia (L-N)<\/td>\n<td height=\"32\">W g\u00f3r\u0119<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,8 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22642,0 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22642,5 kV<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Poziom ochrony napi\u0119ciowej 5kA (L-N)<\/td>\n<td height=\"32\">W g\u00f3r\u0119<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,0 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,1 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,2 kV<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Poziom ochrony napi\u0119cia (N-PE)<\/td>\n<td height=\"32\">W g\u00f3r\u0119<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,5 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,5 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,5 kV<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Maks. bezpiecznik zapasowy<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">160A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">160A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">160A gG<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Wytrzyma\u0142o\u015b\u0107 zwarciowa<\/td>\n<td height=\"32\">Iskr<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tymczasowa odporno\u015b\u0107 na przepi\u0119cia TOV (L-N)<\/td>\n<td height=\"32\">UT<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">335 V\/5 sek.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">400 V\/5 sek.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">500 V\/5 sek.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tymczasowe przepi\u0119cie, awaria bezpieczna dla TOV (L-N)<\/td>\n<td height=\"32\">UT<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">440V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">520V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">650V\/120min.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tymczasowa odporno\u015b\u0107 na przepi\u0119cia TOV (N-PE)<\/td>\n<td height=\"32\">UT<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1200 V\/200 ms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1200 V\/200 ms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1200 V\/200 ms<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Czas reakcji (L-N)<\/td>\n<td height=\"32\">tA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Czas reakcji (N-PE)<\/td>\n<td height=\"32\">tA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100ns<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Zakres temperatur pracy<\/td>\n<td height=\"32\">Wt<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Wskazanie stanu pracy\/usterki<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">zielony\/czerwony<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">zielony\/czerwony<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">zielony\/czerwony<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Powierzchnia przekroju (min.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Powierzchnia przekroju (maks.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Do monta\u017cu<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"5\" align=\"center\" valign=\"middle\" height=\"32\">Szyna DIN 35mm<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Materia\u0142 obudowy<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"5\" align=\"center\" valign=\"middle\" height=\"32\">Tworzywo termoplastyczne UL94-V0<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Stopie\u0144 ochrony<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Kod zam\u00f3wienia<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18873<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18875<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18877<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Kod zam\u00f3wienia (ze zdaln\u0105 sygnalizacj\u0105)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18874<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18876<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18878<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Cechy:<\/strong><\/p>\n<p>1) Du\u017ca pojemno\u015b\u0107 pr\u0105dowa roz\u0142adowania, niskie napi\u0119cie szcz\u0105tkowe, szybka reakcja<\/p>\n<p>2) IP20, UL94 V0<\/p>\n<p>3) Niski pr\u0105d up\u0142ywowy i szybko\u015b\u0107 zmian<\/p>\n<p>4) Urz\u0105dzenia przeciwprzepi\u0119ciowe klasy II \/ typu 2.<\/p>\n<p>5) Technika izolacji cieplnej, brak katastrofy po\u017carowej<\/p>\n<p>6) Cz\u0119\u015bci rdzenia to warystory z tlenku metalu o du\u017cej zdolno\u015bci roz\u0142adowania.<\/p>\n<p>7) Zastosuj specjalne bezpieczniki udarowe o wysokiej niezawodno\u015bci<\/p>\n<p>8) Zgodno\u015b\u0107 z normami: IEC61643-11, EN61643-11<\/p>\n<p>9) Ze wska\u017anikiem zasilania wskazuj\u0105cym stan pracy<\/p>\n<p>10) Ochrona urz\u0105dze\u0144 niskiego napi\u0119cia przed przepi\u0119ciami w uk\u0142adach zasilania TN-S (lub TT 1+1 na zam\u00f3wienie).<\/p>\n<p>11) Obw\u00f3d ochronny kontroli temperatury, wbudowana ochrona przed przegrzaniem, automatyczny modu\u0142 zwalniaj\u0105cy<\/p>\n<p>12) Zamontuj na szynie DIN 35mm.<\/p>\n<p>13) Model ochrony 1+1 (L-N, N-PE), odpowiedni dla s\u0142abego obszaru sieci energetycznej<\/p>\n<p>14) Nominalny pr\u0105d roz\u0142adowania: 50 kA<\/p>\n<p>15) Maks. Pr\u0105d roz\u0142adowania: 110 kA<\/p>\n<p>16) Znakomity proces, mo\u017ce pracowa\u0107 przez d\u0142ugi czas w nieprzyjaznym \u015brodowisku, takim jak kwas, zasady, kurz, mg\u0142a solna, wilgo\u0107 itp.<\/p>\n<p><strong>Aplikacja:<\/strong><\/p>\n<p>1) Tr\u00f3jfazowy SPD zasilania nadaje si\u0119 do ochrony zasilania systemu, takiego jak rozdzielnia, szafa rozdzielcza zasilania, szafa rozdzielcza, tablica rozdzielcza pr\u0105du przemiennego itp.<\/p>\n<p>2) Do stosowania w koncepcji stref ochrony odgromowej na granicy 1-2.<\/p>\n<p>3) Skrzynka rozdzielcza z wej\u015bciem zewn\u0119trznym w budynku i na ka\u017cdym pi\u0119trze<\/p>\n<p>4) Linia energetyczna pr\u0105du przemiennego domu, banku, wie\u017cy telekomunikacyjnej i tak dalej.<\/p>\n<p>5) Urz\u0105dzenie zabezpieczaj\u0105ce przed przepi\u0119ciami pr\u0105du przemiennego jest stosowane w systemie zasilania pr\u0105dem przemiennym (50\/60 Hz) i systemie sterowania niskim napi\u0119ciem w celu ochrony przed uderzeniem pioruna i przej\u015bciowym przepi\u0119ciem.<\/p>\n<p>6) Maszynownia automatyki, panel zasilania g\u0142\u00f3wnej sterowni stacji konwertorowej<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1655\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-11-\u539f\u7406\u56fe.jpg\" alt=\"\" width=\"1799\" height=\"451\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-11-\u539f\u7406\u56fe.jpg 1799w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-11-\u539f\u7406\u56fe-300x75.jpg 300w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-11-\u539f\u7406\u56fe-1024x257.jpg 1024w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-11-\u539f\u7406\u56fe-768x193.jpg 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-11-\u539f\u7406\u56fe-1536x385.jpg 1536w\" sizes=\"auto, (max-width: 1799px) 100vw, 1799px\" \/><\/p>\n<p>&nbsp;<\/p>","protected":false},"parent":0,"menu_order":154,"template":"","meta":{"_acf_changed":false},"product_category":[22],"class_list":["post-1174","product","type-product","status-publish","hentry","product_category-type-2-surge-protective-device"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/product\/1174","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/types\/product"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/media?parent=1174"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/product_category?post=1174"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}