{"id":879,"date":"2025-04-19T10:48:37","date_gmt":"2025-04-19T02:48:37","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=879"},"modified":"2025-04-19T11:23:19","modified_gmt":"2025-04-19T03:23:19","slug":"surge-protection-for-solar-photovoltaic-systems","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/pl\/blog\/surge-protection-for-solar-photovoltaic-systems\/","title":{"rendered":"Ochrona przeciwprzepi\u0119ciowa dla system\u00f3w fotowoltaicznych"},"content":{"rendered":"<h2 data-start=\"52\" data-end=\"119\">Dlaczego urz\u0105dzenia przeciwprzepi\u0119ciowe s\u0105 niezb\u0119dne w systemach fotowoltaicznych<\/h2>\r\n<p class=\"\" data-start=\"121\" data-end=\"486\">Odleg\u0142e lokalizacje, rozleg\u0142e uk\u0142ady i ods\u0142oni\u0119te powierzchnie elektrowni fotowoltaicznych (PV) sprawiaj\u0105, \u017ce s\u0105 one bardzo podatne na zagro\u017cenia \u015brodowiskowe, zw\u0142aszcza burze z wy\u0142adowaniami elektrycznymi. Jednym z najwi\u0119kszych zagro\u017ce\u0144 s\u0105 szkody spowodowane bezpo\u015brednimi lub po\u015brednimi uderzeniami piorun\u00f3w, kt\u00f3re mog\u0105 prowadzi\u0107 do wyd\u0142u\u017conych przestoj\u00f3w systemu, awarii falownika i powa\u017cnych strat w przychodach.<\/p>\r\n<p class=\"\" data-start=\"488\" data-end=\"819\">To mitigate these risks, it's crucial to install surge protection devices (SPDs) for solar PV systems at strategic points, including the solar inverter and array junction boxes. These solar surge protection solutions act as a first line of defence, preventing destructive overvoltages from damaging sensitive equipment.<\/p>\r\n\r\n<h2 data-start=\"826\" data-end=\"893\">Jak wybra\u0107 i zainstalowa\u0107 odpowiednie urz\u0105dzenia przeciwprzepi\u0119ciowe w instalacjach fotowoltaicznych<\/h2>\r\n<p class=\"\" data-start=\"895\" data-end=\"1176\">Systemy fotowoltaiczne dzia\u0142aj\u0105 w specyficznych warunkach, kt\u00f3re wymagaj\u0105 urz\u0105dze\u0144 przeciwprzepi\u0119ciowych PV zaprojektowanych specjalnie do zastosowa\u0144 zwi\u0105zanych z wysokim napi\u0119ciem pr\u0105du sta\u0142ego \u2013 cz\u0119sto do 1500 V. W przeciwie\u0144stwie do system\u00f3w pr\u0105du przemiennego, \u015brodowisko pr\u0105du sta\u0142ego w panelach s\u0142onecznych ma charakter ci\u0105g\u0142y i stwarza wyj\u0105tkowe wyzwania.<\/p>\r\n<p class=\"\" data-start=\"1178\" data-end=\"1274\">Aby wybra\u0107 w\u0142a\u015bciwy SPD dla swojego systemu fotowoltaicznego, nale\u017cy wzi\u0105\u0107 pod uwag\u0119 nast\u0119puj\u0105ce krytyczne czynniki:<\/p>\r\n\r\n<ul data-start=\"1276\" data-end=\"1676\">\r\n \t<li class=\"\" data-start=\"1276\" data-end=\"1336\">\r\n<p class=\"\" data-start=\"1278\" data-end=\"1336\">G\u0119sto\u015b\u0107 wy\u0142adowa\u0144 atmosferycznych w obszarze instalacji<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1337\" data-end=\"1385\">\r\n<p class=\"\" data-start=\"1339\" data-end=\"1385\">Zakres temperatur pracy systemu<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1386\" data-end=\"1444\">\r\n<p class=\"\" data-start=\"1388\" data-end=\"1444\">Napi\u0119cie znamionowe systemu DC (cz\u0119sto do 1500 V)<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1445\" data-end=\"1500\">\r\n<p class=\"\" data-start=\"1447\" data-end=\"1500\">Pr\u0105d zwarciowy (Isc) uk\u0142adu fotowoltaicznego<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1501\" data-end=\"1583\">\r\n<p class=\"\" data-start=\"1503\" data-end=\"1583\">Rodzaj nara\u017cenia na przepi\u0119cie (przej\u015bciowe, bezpo\u015brednie lub po\u015brednie pioruny)<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1584\" data-end=\"1676\">\r\n<p class=\"\" data-start=\"1586\" data-end=\"1676\">Wymagany znamionowy pr\u0105d wy\u0142adowczy (In) i stopie\u0144 ochrony (np. typ 1+2 SPD)<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p class=\"\" data-start=\"1678\" data-end=\"1893\">Aby zapewni\u0107 skuteczn\u0105 ochron\u0119, poziom ochrony napi\u0119ciowej (Up) wybranego SPD musi by\u0107 co najmniej o 20% ni\u017cszy ni\u017c wytrzyma\u0142o\u015b\u0107 dielektryczna pod\u0142\u0105czonego sprz\u0119tu, takiego jak falownik lub skrzynka po\u0142\u0105czeniowa.<\/p>\r\n<p class=\"\" data-start=\"1895\" data-end=\"2114\">Wdro\u017cenie odpowiedniej ochrony odgromowej w fotowoltaice to nie tylko \u015brodek bezpiecze\u0144stwa \u2014 jest niezb\u0119dny do utrzymania czasu pracy systemu, wyd\u0142u\u017cenia \u017cywotno\u015bci sprz\u0119tu i ochrony inwestycji w energi\u0119 odnawialn\u0105.<\/p>\r\nIt is important to use an SPD with a short circuit withstand current greater than the short circuit current of the solar array string that the SPD is connected to. The SPD that is provided on the dc output must have a dc MCOV equal to or greater than the maximum photovoltaic system voltage of the panel.\r\n\r\nWhen a lightning strikes at point A (see Figure 1), the solar PV panel and the inverter are likely to be damaged. Only the inverter will be damaged if the lightning strikes at point B. However, the inverter is typically the most expensive component within a PV system, which is why it is essential to properly select and install the correct SPD on both the ac and dc lines. The closer the strike is to the inverter, the more damaged the inverter will be.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/pl\/product\/brpv3-600-type-2-surge-protection-device-for-pv-upto-600v\/\" rel=\"attachment wp-att-2054\"><img class=\"alignnone wp-image-2054 size-large\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/07\/Surge-Protection-Devices-For-Solar-PV-1024x1024.webp\" alt=\"Urz\u0105dzenia przeciwprzepi\u0119ciowe do fotowoltaiki\" width=\"1024\" height=\"1024\" \/><\/a>\r\n<h2><strong>Urz\u0105dzenia SPD po stronie DC i AC do skrzynek po\u0142\u0105czeniowych i falownik\u00f3w<\/strong><\/h2>\r\nSurge-protection devices are installed on the DC and AC sides of central and string inverters, in combiner boxes and to protect signal lines (measurements and communications). Depending on the atmospheric exposure of the PV plant to lightning, engineering, procurement and construction (EPC) contractors and designers may prescribe either standard type 2 IEC SPDs (indirect impact 8\/20 \u03bcs) or more robust type 1+2 SPDs (tested to withstand direct lightning impacts in 10\/350 \u03bcs waveform).\r\n\r\nDC side protection at combiner boxes and inverters typically has a Y-connection DIN-rail configuration in order to provide common and differential mode protection.\r\n\r\nOn the AC side, overvoltage protection of the inverter is likewise required. Whether at the inverter itself or at the AC combiner box, exposure to voltage surges is generally addressed by using standard DIN-rail type 2 SPDs in TN S, IT or even TT configurations.\r\n\r\nMoreover, depending on the PV installation, type 1+2 AC may be favored in some cases by EPC contractors and designers, in order to achieve a longer lifetime for SPDs and even protection where conditions are harsher in terms of the expected direct lightning impact. This will typically be the case in areas with a very high isoceraunic level, often associated with high altitudes.","protected":false},"featured_media":880,"parent":0,"menu_order":138,"template":"","meta":{"_acf_changed":false},"blog_category":[9],"class_list":["post-879","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-industry-news"],"acf":{"des":"The remote locations, exposed surface areas and extensive layouts of solar power plants put them at high risk of damage from the elements, particularly electrical storms.","txt":"<h2 data-start=\"52\" data-end=\"119\">Why Surge Protection Devices Are Essential for Solar PV Systems<\/h2>\r\n<p class=\"\" data-start=\"121\" data-end=\"486\">The remote locations, expansive layouts, and exposed surfaces of solar photovoltaic (PV) power plants make them highly vulnerable to environmental hazards \u2014 especially electrical storms. One of the biggest risks is damage caused by direct or indirect lightning strikes, which can lead to extended system downtime, inverter failure, and major revenue losses.<\/p>\r\n<p class=\"\" data-start=\"488\" data-end=\"819\">To mitigate these risks, it's crucial to install surge protection devices (SPDs) for solar PV systems at strategic points, including the solar inverter and array junction boxes. These solar surge protection solutions act as a first line of defence, preventing destructive overvoltages from damaging sensitive equipment.<\/p>\r\n\r\n<h2 data-start=\"826\" data-end=\"893\">How to Select and Install the Right PV Surge Protection Devices<\/h2>\r\n<p class=\"\" data-start=\"895\" data-end=\"1176\">Photovoltaic systems operate under specific conditions that require PV surge protection devices specifically engineered for high-voltage DC applications \u2014 often up to 1500V. Unlike AC systems, the DC environment in solar arrays is continuous and presents unique challenges.<\/p>\r\n<p class=\"\" data-start=\"1178\" data-end=\"1274\">To choose the correct SPD for your solar PV system, consider the following critical factors:<\/p>\r\n\r\n<ul data-start=\"1276\" data-end=\"1676\">\r\n \t<li class=\"\" data-start=\"1276\" data-end=\"1336\">\r\n<p class=\"\" data-start=\"1278\" data-end=\"1336\">The lightning flash density in the installation area<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1337\" data-end=\"1385\">\r\n<p class=\"\" data-start=\"1339\" data-end=\"1385\">The system\u2019s operating temperature range<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1386\" data-end=\"1444\">\r\n<p class=\"\" data-start=\"1388\" data-end=\"1444\">The system\u2019s DC voltage rating (often up to 1500V)<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1445\" data-end=\"1500\">\r\n<p class=\"\" data-start=\"1447\" data-end=\"1500\">The short-circuit current (Isc) of the PV array<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1501\" data-end=\"1583\">\r\n<p class=\"\" data-start=\"1503\" data-end=\"1583\">The type of overvoltage exposure (transient, direct or indirect lightning)<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1584\" data-end=\"1676\">\r\n<p class=\"\" data-start=\"1586\" data-end=\"1676\">The required nominal discharge current (In) and protection class (e.g. Type 1+2 SPD)<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p class=\"\" data-start=\"1678\" data-end=\"1893\">To ensure effective protection, the voltage protection level (Up) of the selected SPD must be at least 20% lower than the dielectric strength of the connected equipment, such as the inverter or combiner box.<\/p>\r\n<p class=\"\" data-start=\"1895\" data-end=\"2114\">Implementing the right lightning protection for solar PV is not just a safety measure \u2014 it\u2019s essential for maintaining system uptime, extending equipment lifespan, and protecting your investment in renewable energy.<\/p>\r\nIt is important to use an SPD with a short circuit withstand current greater than the short circuit current of the solar array string that the SPD is connected to. The SPD that is provided on the dc output must have a dc MCOV equal to or greater than the maximum photovoltaic system voltage of the panel.\r\n\r\nWhen a lightning strikes at point A (see Figure 1), the solar PV panel and the inverter are likely to be damaged. Only the inverter will be damaged if the lightning strikes at point B. However, the inverter is typically the most expensive component within a PV system, which is why it is essential to properly select and install the correct SPD on both the ac and dc lines. The closer the strike is to the inverter, the more damaged the inverter will be.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/brpv3-600-type-2-surge-protection-device-for-pv-upto-600v\/\" rel=\"attachment wp-att-2054\"><img class=\"alignnone wp-image-2054 size-large\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/07\/Surge-Protection-Devices-For-Solar-PV-1024x1024.webp\" alt=\"Surge Protection Devices For Solar PV\" width=\"1024\" height=\"1024\" \/><\/a>\r\n<h2><strong>DC &amp; AC Side SPDs for combiner boxes and inverters<\/strong><\/h2>\r\nSurge-protection devices are installed on the DC and AC sides of central and string inverters, in combiner boxes and to protect signal lines (measurements and communications). Depending on the atmospheric exposure of the PV plant to lightning, engineering, procurement and construction (EPC) contractors and designers may prescribe either standard type 2 IEC SPDs (indirect impact 8\/20 \u03bcs) or more robust type 1+2 SPDs (tested to withstand direct lightning impacts in 10\/350 \u03bcs waveform).\r\n\r\nDC side protection at combiner boxes and inverters typically has a Y-connection DIN-rail configuration in order to provide common and differential mode protection.\r\n\r\nOn the AC side, overvoltage protection of the inverter is likewise required. Whether at the inverter itself or at the AC combiner box, exposure to voltage surges is generally addressed by using standard DIN-rail type 2 SPDs in TN S, IT or even TT configurations.\r\n\r\nMoreover, depending on the PV installation, type 1+2 AC may be favored in some cases by EPC contractors and designers, in order to achieve a longer lifetime for SPDs and even protection where conditions are harsher in terms of the expected direct lightning impact. This will typically be the case in areas with a very high isoceraunic level, often associated with high altitudes."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/blog\/879","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/media\/880"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/media?parent=879"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/blog_category?post=879"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}