{"id":864,"date":"2023-12-14T15:36:02","date_gmt":"2023-12-14T07:36:02","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=864"},"modified":"2024-09-05T16:40:57","modified_gmt":"2024-09-05T08:40:57","slug":"how-does-spd-surge-protection-device-work","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/pl\/blog\/how-does-spd-surge-protection-device-work\/","title":{"rendered":"Jak dzia\u0142a SPD (urz\u0105dzenie przeciwprzepi\u0119ciowe)?"},"content":{"rendered":"Surge protective devices (SPDs) are essential devices that protect electrical equipment from damage caused by voltage spikes or surges. These surges, which can be caused by lightning or power outages, can interfere with and even destroy sensitive electronic devices.\r\n\r\nSPDs work by diverting the excess voltage that is generated during a surge away from the devices that are being protected. They do this by moving the excess energy through a path that leads to the ground, away from the equipment. SPDs can be installed at the point where electrical power enters a building or even on individual devices to protect them from the voltage spikes.\r\n\r\nThe two major components of SPDs are metal oxide varistors (MOVs) and gas discharge tubes (GDTs). MOVs are made of a metal oxide and are designed to conduct electricity when a voltage surge occurs. When the voltage exceeds a certain threshold, the MOV conducts electricity, shunting the excess voltage away from the equipment it\u2019s protecting. GDTs work in a similar way, by breaking down and conducting excess voltage away from the device.\r\n\r\nIn addition to MOVs and GDTs, SPDs also usually include a fuse called a transient voltage suppressor (TVS). The TVS helps protect the SPD and the equipment it\u2019s connected to from any short circuits that may occur.\r\n\r\nIn summary, SPDs are critical devices that help protect electronic equipment from potentially harmful voltage surges. Without them, devices could be easily destroyed by surges caused by lightning, power outages, or other voltage fluctuations. With the right use of SPDs in place, you can have peace of mind and protect your valuable electronic devices from unexpected surges and outages.\r\n\r\n<strong>Kategorie lub typy SPD<\/strong>\r\n\r\nThe two main types of SPDs are voltage limiting and voltage switching components. Voltage limiting components change in impedance as the voltages rise, resulting in clamping the transient voltage. Voltage switching components \u201cturn on\u201d once a threshold voltage is exceeded and immediately drop to low impedance. Most systems today incorporate both component types together to aggregate the strengths and limit the weaknesses of each individual part.\r\n\r\nExamples of voltage limiting components are metal oxide varistors (MOVs) and transient voltage suppression (TVS) diodes. Voltage switching components include gas discharge tubes (GDTs) and spark gaps.\r\n\r\n<strong>Zasada dzia\u0142ania<\/strong>\r\n\r\nSPDs can vary in types but they have a common working principle: At normal voltage, it doesn\u2019t affect the operation of the circuit. Once the high spike voltage is generated, the impedance of the surge protection device will decrease very quickly. Thus, the surge current will flow into the ground through the surge protector instead of entering the equipment to protect the circuits and other equipment connected to it.\r\n\r\nTypes of SPD\r\n\r\n<img class=\"aligncenter wp-image-17913 size-full\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/24.png\" sizes=\"(max-width: 806px) 100vw, 806px\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/24.png 806w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/24-400x211.png 400w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/24-768x406.png 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/24-600x317.png 600w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/24-150x79.png 150w\" alt=\"\" width=\"806\" height=\"426\" \/>\r\n\r\nTypes of SPD depend on the location, at which it is installed,\r\n\r\nType 1 SPDs \u2013 Main Distribution Panel\r\n\r\nType 2 SPDs \u2013 Sub-Distribution Panel\r\n\r\nType 3 SPDs \u2013 Load Protection Panel\r\n\r\nBy technology, there are two types of SPDs, Namely,\r\n<ul>\r\n \t<li>Rura wy\u0142adowcza gazowa (GDT) \u2013 wykorzystuje iskiernik umieszczony na elektrodach umieszczonych w szczelnym szkle wype\u0142nionym gazami szlachetnymi, kt\u00f3re s\u0105 zaprojektowane tak, aby rozk\u0142ada\u0107 si\u0119 przy napi\u0119ciu wy\u017cszym ni\u017c napi\u0119cie robocze, powoduj\u0105c przewodzenie. Jest to uk\u0142ad prze\u0142\u0105czaj\u0105cy napi\u0119cie (dzia\u0142a wolniej ni\u017c MOV).<\/li>\r\n \t<li>Warystor z tlenku metalu (MOV) \u2013 MOV to okr\u0105g\u0142y\/prostok\u0105tny korpus ze spiekanego tlenku cynku i innych tlenk\u00f3w w postaci jedno- lub wielowarstwowej kanapki. Kiedy pojawia si\u0119 przepi\u0119cie, rezystancja w MOV gwa\u0142townie maleje, powoduj\u0105c du\u017cy przep\u0142yw pr\u0105du. MOV to system ograniczania napi\u0119cia (dzia\u0142a szybciej ni\u017c GDT).<\/li>\r\n \t<li>Dioda przebicia lawinowego (ABD) \u2013 dioda z\u0142\u0105czowa P-N zaprojektowana tak, aby ulega\u0142a przebiciu lawinowemu (zjawisku elektrycznemu w p\u00f3\u0142przewodniku, kt\u00f3re umo\u017cliwia przep\u0142yw du\u017cych ilo\u015bci pr\u0105du) po przy\u0142o\u017ceniu napi\u0119cia wi\u0119kszego ni\u017c napi\u0119cie znamionowe.<\/li>\r\n<\/ul>","protected":false},"featured_media":865,"parent":0,"menu_order":145,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-864","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"Surge protective devices (SPDs) are essential devices that protect electrical equipment from damage caused by voltage spikes or surges. These surges, which can be caused by lightning or power outages, can interfere with and even destroy sensitive electronic devices.","txt":"Surge protective devices (SPDs) are essential devices that protect electrical equipment from damage caused by voltage spikes or surges. These surges, which can be caused by lightning or power outages, can interfere with and even destroy sensitive electronic devices.\r\n\r\nSPDs work by diverting the excess voltage that is generated during a surge away from the devices that are being protected. They do this by moving the excess energy through a path that leads to the ground, away from the equipment. SPDs can be installed at the point where electrical power enters a building or even on individual devices to protect them from the voltage spikes.\r\n\r\nThe two major components of SPDs are metal oxide varistors (MOVs) and gas discharge tubes (GDTs). MOVs are made of a metal oxide and are designed to conduct electricity when a voltage surge occurs. When the voltage exceeds a certain threshold, the MOV conducts electricity, shunting the excess voltage away from the equipment it\u2019s protecting. GDTs work in a similar way, by breaking down and conducting excess voltage away from the device.\r\n\r\nIn addition to MOVs and GDTs, SPDs also usually include a fuse called a transient voltage suppressor (TVS). The TVS helps protect the SPD and the equipment it\u2019s connected to from any short circuits that may occur.\r\n\r\nIn summary, SPDs are critical devices that help protect electronic equipment from potentially harmful voltage surges. Without them, devices could be easily destroyed by surges caused by lightning, power outages, or other voltage fluctuations. With the right use of SPDs in place, you can have peace of mind and protect your valuable electronic devices from unexpected surges and outages.\r\n\r\n<strong>SPD Categories or Types<\/strong>\r\n\r\nThe two main types of SPDs are voltage limiting and voltage switching components. Voltage limiting components change in impedance as the voltages rise, resulting in clamping the transient voltage. Voltage switching components \u201cturn on\u201d once a threshold voltage is exceeded and immediately drop to low impedance. Most systems today incorporate both component types together to aggregate the strengths and limit the weaknesses of each individual part.\r\n\r\nExamples of voltage limiting components are metal oxide varistors (MOVs) and transient voltage suppression (TVS) diodes. Voltage switching components include gas discharge tubes (GDTs) and spark gaps.\r\n\r\n<strong>Working Principle<\/strong>\r\n\r\nSPDs can vary in types but they have a common working principle: At normal voltage, it doesn\u2019t affect the operation of the circuit. Once the high spike voltage is generated, the impedance of the surge protection device will decrease very quickly. Thus, the surge current will flow into the ground through the surge protector instead of entering the equipment to protect the circuits and other equipment connected to it.\r\n\r\nTypes of SPD\r\n\r\n<img class=\"aligncenter wp-image-17913 size-full\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/24.png\" sizes=\"(max-width: 806px) 100vw, 806px\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/24.png 806w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/24-400x211.png 400w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/24-768x406.png 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/24-600x317.png 600w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/24-150x79.png 150w\" alt=\"\" width=\"806\" height=\"426\" \/>\r\n\r\nTypes of SPD depend on the location, at which it is installed,\r\n\r\nType 1 SPDs \u2013 Main Distribution Panel\r\n\r\nType 2 SPDs \u2013 Sub-Distribution Panel\r\n\r\nType 3 SPDs \u2013 Load Protection Panel\r\n\r\nBy technology, there are two types of SPDs, Namely,\r\n<ul>\r\n \t<li>Gas Discharge Tube (GDT) \u2013 Uses a spark gap across electrodes placed in a sealed glass filled with noble gases which are designed to break down at a voltage higher than the operating voltage causing it to conduct. This is a voltage-switching system (acts slower than MOV).<\/li>\r\n \t<li>Metal Oxide Varistor (MOV) \u2013 An MOV is a circular\/rectangular-shaped body of sintered Zinc Oxide &amp; other oxides of a single\/multilayer sandwich of the same. When a surge occurs, the resistance across the MOV rapidly decreases causing a large current flow. MOVs are Voltage limiting system (acts quicker than GDT).<\/li>\r\n \t<li>Avalanche Breakdown Diode (ABD) \u2013 A P-N Junction diode designed to experience an avalanche breakdown (an electrical phenomenon in a semiconductor that allows large amounts of current to flow) when a voltage is applied that is greater than the rated voltage.<\/li>\r\n<\/ul>"},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/blog\/864","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/media\/865"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/media?parent=864"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/blog_category?post=864"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}