{"id":858,"date":"2023-12-17T15:26:05","date_gmt":"2023-12-17T07:26:05","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=858"},"modified":"2024-09-05T16:40:33","modified_gmt":"2024-09-05T08:40:33","slug":"surge-protective-devices-spd","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/pl\/blog\/surge-protective-devices-spd\/","title":{"rendered":"Urz\u0105dzenia przeciwprzepi\u0119ciowe (SPD)"},"content":{"rendered":"Surge Protective Devices (SPD) are used to protect the electrical installation, which consists of the consumer unit, wiring and accessories, from electrical power surges known as transient overvoltage.\r\n\r\nEvery piece of electronic equipment found in an industrial environment is subjected to power surges generated on the utility grid are transmitted to the equipment via incoming power lines. Users are installing surge protection devices to protect their equipment from surges.\r\n\r\nThere are three different types of Surge Protective Devices:\r\n<ol>\r\n \t<li>SPD typu 1 instalowany na pocz\u0105tku, np. g\u0142\u00f3wna tablica rozdzielcza.<\/li>\r\n \t<li>SPD typu 2 instalowane w podrozdzielniach (dost\u0119pne s\u0105 kombinowane SPD typu 1 i 2, kt\u00f3re s\u0105 zwykle instalowane w jednostkach konsumenckich).<\/li>\r\n \t<li>SPD typu 3 zainstalowany w pobli\u017cu chronionego obci\u0105\u017cenia. Mo\u017cna je instalowa\u0107 wy\u0142\u0105cznie jako uzupe\u0142nienie SPD typu 2.<\/li>\r\n<\/ol>\r\nJe\u017celi do ochrony instalacji wymaganych jest wiele urz\u0105dze\u0144, nale\u017cy je skoordynowa\u0107, aby zapewni\u0107 prawid\u0142owe dzia\u0142anie. Elementy dostarczane przez r\u00f3\u017cnych producent\u00f3w powinny zosta\u0107 potwierdzone pod k\u0105tem zgodno\u015bci. Instalator i producenci urz\u0105dze\u0144 s\u0105 najlepiej przygotowani, aby udzieli\u0107 wskaz\u00f3wek w tym zakresie.\r\n\r\n<strong>SPD typu 1<\/strong>\r\n\r\nSPD Type 1 must be connected upstream of the system, at the point of delivery of power energy. SPD protects buildings and people from the risk of direct lightning (fire and death) and is characterized by:\r\n\r\nIimp 10\/350 Impulse current: Iimp corresponds to the peak value of a 10\/350 \u03bcs current impulse waveform.\r\n\r\n<strong>SPD typu 2<\/strong>\r\n\r\nSPD Type 2 devices are designed to remove all the overvoltage from supply circuits that are not likely to be directly hit by lightning. SPD Type 2 is connected downstream SPD Type 1 or SPD Type 1+2, (minimum distance 1 m) and they protect machines and tools connected to the ground and reduce the risk of economic loss.\r\n\r\nSPD Type 2 is characterized by:\r\n\r\nIn 8\/20 Nominal discharge current: The peak current (and waveform shape) through the SPD under conditions prescribed by EN 62305 to represent the surge current as a consequence of a lightning strike to the electric supply line.\r\n\r\nImax 8\/20 Maximum discharge current: Peak value of the highest current of an 8\/20 \u03bcs waveform that an SPD can discharge at least once without breaking.\r\n\r\n<strong>SPD typu 3<\/strong>\r\n\r\nSPD type 3 devices are used to protect the end user from overvoltage. They may be installed in supply networks where SDP types 1 and\/or 2 already exist. They can be installed in fixed or mobile sockets and have the following characteristic parameters:\r\n\r\nUoc: test voltage. This is the peak value of the no-load voltage of the combined test-generator; this has a waveform of 1.2\/50 \u03bcs and can supply at the same time current with waveform 8\/20 \u03bcs\r\n\r\n<strong>Co to jest przepi\u0119cie przej\u015bciowe?<\/strong>\r\n\r\nPrzej\u015bciowe przepi\u0119cie definiuje si\u0119 jako kr\u00f3tkotrwa\u0142e przepi\u0119cia pr\u0105du, kt\u00f3re powstaj\u0105 w wyniku nag\u0142ego uwolnienia energii uprzednio zmagazynowanej lub indukowanej w inny spos\u00f3b. Przej\u015bciowe przepi\u0119cie mo\u017ce by\u0107 naturalne lub spowodowane przez cz\u0142owieka.\r\n\r\n<strong>\u0179r\u00f3d\u0142a przepi\u0119\u0107 mog\u0105 by\u0107 zewn\u0119trzne lub wewn\u0119trzne.<\/strong>\r\n\r\nExternal transient overvoltage is:\r\n\r\nLightning (most damaging)\r\n\r\nSwitching of capacitor banks\r\n\r\nSwitching of large electrical loads\r\n\r\nPower line disconnection and reconnection\r\n\r\nTransformer switching\r\n\r\nElectrostatic discharges\r\n\r\nPoor power transmission and distribution grid quality\r\n\r\nInternal transient overvoltage is:\r\n\r\nFuse and circuit breaker (MCCB, ACB, etc.)\r\n\r\nElectrical motors and motor starters\r\n\r\nHVAC devices\r\n\r\nVariable frequency drives\r\n\r\nHousehold devices such as microwave oven, computer, refrigerator\r\n\r\nElectronic ballasts\r\n\r\n<strong>Technologie urz\u0105dze\u0144 przeciwprzepi\u0119ciowych<\/strong>\r\n\r\nVaristor:\r\n\r\nThis can be considered as a variable resistance that at nominal voltage has a very high ohmic value. But the resistance rapidly falls to near zero as the voltage surges. In this way, the varistor applies a near short circuit that clamps the surge voltage. The varistor is however subject to progressive degradation due to the small leakage current that occurs at the nominal voltage, and with the number of interventions. With every overvoltage that occurs the leakage current rises and accelerates the end of life for the device \u2013 which is ultimately indicated by the change from green to red in the signal window.\r\n\r\nSpark gap:\r\n\r\nThis comprises two electrodes separated by air or gas. When a surge voltage occurs electrical arc bridges the gap and a surge current flow to limit the surge voltage to a low and constant level. The arc extinguishes only when the surge current falls below about 10 amperes. The gas guarantees a constant level of breakdown voltage since the arc is struck in a protected environment; not exposed to pressure or humidity variations or impurities as would happen if it had occurred in the air. There is, however, a delay before the device arcs and the surge current is diverted, and this is dependent on the magnitude of the original voltage surge and its rate of rising. Therefore, the voltage protection level can vary, although it is guaranteed to be less than up.\r\n\r\n<strong>Czy musz\u0119 mie\u0107 zainstalowane SPD?<\/strong>\r\n\r\nAktualne wydanie przepis\u00f3w dotycz\u0105cych okablowania IET, BS 7671:2018, stanowi, \u017ce je\u015bli nie zostanie przeprowadzona ocena ryzyka, nale\u017cy zapewni\u0107 ochron\u0119 przed przej\u015bciowym przepi\u0119ciem, je\u017celi skutki spowodowane przepi\u0119ciem mog\u0105:\r\n<ul>\r\n \t<li>Spowodowa\u0107 powa\u017cne obra\u017cenia lub utrat\u0119 \u017cycia ludzkiego;<\/li>\r\n \t<li>spowodowa\u0107 przerw\u0119 w \u015bwiadczeniu us\u0142ug publicznych i\/lub szkody w dziedzictwie kulturowym;<\/li>\r\n \t<li>spowodowa\u0107 przerw\u0119 w dzia\u0142alno\u015bci handlowej lub przemys\u0142owej;<\/li>\r\n \t<li>Wp\u0142yw na du\u017c\u0105 liczb\u0119 przebywaj\u0105cych w pobli\u017cu os\u00f3b.<\/li>\r\n<\/ul>\r\nThis regulation applies to all types of premises which include domestic, commercial and industrial.\r\n\r\nThe decision on whether to purchase SPDs is in the hands of the customer, but they should be provided with enough information to make an informed decision on whether they wish to omit SPDs.\r\n\r\nSurge protection could be installed in an existing consumer unit if appropriate physical space was available or, if enough space was not available, it could be installed in an external enclosure adjacent to the existing consumer unit.","protected":false},"featured_media":859,"parent":0,"menu_order":148,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-858","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"Surge Protective Devices (SPD) are used to protect the electrical installation, which consists of the consumer unit, wiring and accessories, from electrical power surges known as transient overvoltage.","txt":"Surge Protective Devices (SPD) are used to protect the electrical installation, which consists of the consumer unit, wiring and accessories, from electrical power surges known as transient overvoltage.\r\n\r\nEvery piece of electronic equipment found in an industrial environment is subjected to power surges generated on the utility grid are transmitted to the equipment via incoming power lines. Users are installing surge protection devices to protect their equipment from surges.\r\n\r\nThere are three different types of Surge Protective Devices:\r\n<ol>\r\n \t<li>Type 1 SPD installed at the origin, e.g. main distribution board.<\/li>\r\n \t<li>Type 2 SPD installed at sub-distribution boards (Combined Type 1 &amp; 2 SPDs are available and are usually installed in consumer units).<\/li>\r\n \t<li>Type 3 SPD installed close to the protected load. They must only be installed as a supplement to Type 2 SPD.<\/li>\r\n<\/ol>\r\nWhere multiple devices are required to protect the installation, they must be coordinated to ensure correct operation. Items supplied by different manufacturers should be confirmed for compatibility, the installer and manufacturers of the devices are best placed to provide guidance on this.\r\n\r\n<strong>Type 1 SPD<\/strong>\r\n\r\nSPD Type 1 must be connected upstream of the system, at the point of delivery of power energy. SPD protects buildings and people from the risk of direct lightning (fire and death) and is characterized by:\r\n\r\nIimp 10\/350 Impulse current: Iimp corresponds to the peak value of a 10\/350 \u03bcs current impulse waveform.\r\n\r\n<strong>Type 2 SPD<\/strong>\r\n\r\nSPD Type 2 devices are designed to remove all the overvoltage from supply circuits that are not likely to be directly hit by lightning. SPD Type 2 is connected downstream SPD Type 1 or SPD Type 1+2, (minimum distance 1 m) and they protect machines and tools connected to the ground and reduce the risk of economic loss.\r\n\r\nSPD Type 2 is characterized by:\r\n\r\nIn 8\/20 Nominal discharge current: The peak current (and waveform shape) through the SPD under conditions prescribed by EN 62305 to represent the surge current as a consequence of a lightning strike to the electric supply line.\r\n\r\nImax 8\/20 Maximum discharge current: Peak value of the highest current of an 8\/20 \u03bcs waveform that an SPD can discharge at least once without breaking.\r\n\r\n<strong>Type 3 SPD<\/strong>\r\n\r\nSPD type 3 devices are used to protect the end user from overvoltage. They may be installed in supply networks where SDP types 1 and\/or 2 already exist. They can be installed in fixed or mobile sockets and have the following characteristic parameters:\r\n\r\nUoc: test voltage. This is the peak value of the no-load voltage of the combined test-generator; this has a waveform of 1.2\/50 \u03bcs and can supply at the same time current with waveform 8\/20 \u03bcs\r\n\r\n<strong>What is transient overvoltage?<\/strong>\r\n\r\nTransient overvoltage is defined as short duration surges of electricity which occur due to the sudden release of energy previously-stored or induced by other means. Transient overvoltage can be either naturally occurring or man-made.\r\n\r\n<strong>Sources of power surges can be external or internal.<\/strong>\r\n\r\nExternal transient overvoltage is:\r\n\r\nLightning (most damaging)\r\n\r\nSwitching of capacitor banks\r\n\r\nSwitching of large electrical loads\r\n\r\nPower line disconnection and reconnection\r\n\r\nTransformer switching\r\n\r\nElectrostatic discharges\r\n\r\nPoor power transmission and distribution grid quality\r\n\r\nInternal transient overvoltage is:\r\n\r\nFuse and circuit breaker (MCCB, ACB, etc.)\r\n\r\nElectrical motors and motor starters\r\n\r\nHVAC devices\r\n\r\nVariable frequency drives\r\n\r\nHousehold devices such as microwave oven, computer, refrigerator\r\n\r\nElectronic ballasts\r\n\r\n<strong>Surge protection device technologies<\/strong>\r\n\r\nVaristor:\r\n\r\nThis can be considered as a variable resistance that at nominal voltage has a very high ohmic value. But the resistance rapidly falls to near zero as the voltage surges. In this way, the varistor applies a near short circuit that clamps the surge voltage. The varistor is however subject to progressive degradation due to the small leakage current that occurs at the nominal voltage, and with the number of interventions. With every overvoltage that occurs the leakage current rises and accelerates the end of life for the device \u2013 which is ultimately indicated by the change from green to red in the signal window.\r\n\r\nSpark gap:\r\n\r\nThis comprises two electrodes separated by air or gas. When a surge voltage occurs electrical arc bridges the gap and a surge current flow to limit the surge voltage to a low and constant level. The arc extinguishes only when the surge current falls below about 10 amperes. The gas guarantees a constant level of breakdown voltage since the arc is struck in a protected environment; not exposed to pressure or humidity variations or impurities as would happen if it had occurred in the air. There is, however, a delay before the device arcs and the surge current is diverted, and this is dependent on the magnitude of the original voltage surge and its rate of rising. Therefore, the voltage protection level can vary, although it is guaranteed to be less than up.\r\n\r\n<strong>Do I have to have SPDs installed?<\/strong>\r\n\r\nThe current edition of the IET Wiring Regulations, BS 7671:2018, states that unless a risk assessment is carried out, protection against transient overvoltage shall be provided where the consequence caused by overvoltage could:\r\n<ul>\r\n \t<li>Result in serious injury to, or loss of, human life;<\/li>\r\n \t<li>Result in interruption of public services and\/or damage to cultural heritage;<\/li>\r\n \t<li>Result in interruption of commercial or industrial activity;<\/li>\r\n \t<li>Affect a large number of co-located individuals.<\/li>\r\n<\/ul>\r\nThis regulation applies to all types of premises which include domestic, commercial and industrial.\r\n\r\nThe decision on whether to purchase SPDs is in the hands of the customer, but they should be provided with enough information to make an informed decision on whether they wish to omit SPDs.\r\n\r\nSurge protection could be installed in an existing consumer unit if appropriate physical space was available or, if enough space was not available, it could be installed in an external enclosure adjacent to the existing consumer unit."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/blog\/858","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/media\/859"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/media?parent=858"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/blog_category?post=858"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}